<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Scambiatori a piastre Archivi - Tempco Blog</title>
	<atom:link href="https://www.tempco.it/blog/en/category/scambiatori-a-piastre-en/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.tempco.it/blog/en/category/scambiatori-a-piastre-en/</link>
	<description>Solutions for the thermal energy</description>
	<lastBuildDate>Thu, 19 Nov 2026 11:00:21 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>
	<item>
		<title>Injection molding and heating element failure in temperature control units (TCUs)</title>
		<link>https://www.tempco.it/blog/en/11620/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 19 Nov 2026 11:00:21 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[Maintenance]]></category>
		<category><![CDATA[Manutenzione]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[Service]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[composites]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[cracking]]></category>
		<category><![CDATA[failure of heating elements]]></category>
		<category><![CDATA[heat exchanger calculation]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[heating elements]]></category>
		<category><![CDATA[molding]]></category>
		<category><![CDATA[oversizing]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[proportional valves]]></category>
		<category><![CDATA[sizing]]></category>
		<category><![CDATA[solenoid valves]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[temperature control]]></category>
		<category><![CDATA[temperature control units]]></category>
		<category><![CDATA[temperature controllers]]></category>
		<category><![CDATA[temperature regulation]]></category>
		<category><![CDATA[thermal shock]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11620</guid>

					<description><![CDATA[<p>Failure of heating elements in a temperature control unit (TCU) used for the injection molding of composite materials; an analysis conducted by Tempco identified the root cause as the oversizing of the plate heat exchanger.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11620/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus/">Injection molding and heating element failure in temperature control units (TCUs)</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>In precision temperature control, the correct <strong>sizing of <a href="https://en.tempco.it/solutions-en/heat-exchangers/" target="_blank" rel="noopener">heat exchangers</a></strong> is more important than having an excess of power. In fact, an oversized heat exchanger was the root cause of <strong>heating element failure in a <a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener">temperature control unit</a></strong> (TCU) used for the <a href="https://www.tempco.it/blog/en/10503/thermoregulation-in-carbon-fiber-composite-materials-molding/" target="_blank" rel="noopener"><strong>injection molding</strong></a> of a PP-based composite material. The client—an overseas company—contacted Tempco to investigate the underlying cause of the malfunction.</p>
<p>Our first step was to <strong>collect process data</strong> during an on-site visit conducted by the Tempco partner:</p>
<ul>
<li>a steel mold weighing ~12 tons, with a throughput of ~60 kg/h;</li>
<li>4 temperature control zones, managed by 3 TCU operating at 60, 80, and 100 °C;</li>
<li>cooling water available at 15 °C;</li>
<li>the material is heated up to ~250 °C for injection and subsequently cooled down to ~80 °C;</li>
<li>actual cooling load required: ΔT 170 °C × 60 kg/h × specific heat capacity (Cs) 0.45 ≈ 5.3 kW net;</li>
<li>highly stable process temperature.</li>
</ul>
<p>As previously mentioned, the client’s issue involved the <strong>failure of the heating elements</strong> within their temperature control units (TCUs). A joint analysis conducted by Tempco and our local partner identified the likely cause: thermal shock resulting from a significantly <strong>oversized plate heat exchanger</strong>—60 kW capacity, compared to an actual cooling duty required of only ~5.3 kW. With such an oversized exchanger, combined with an on/off cooling solenoid valve, every activation delivers a <strong>sudden, disproportionate cooling &#8216;jolt&#8217;</strong>. This causes sharp thermal fluctuations in the process water, leading the heating elements to develop cracks and eventually fail. This is a classic example of how over-sizing the capacity of a heat exchanger does not enhance operational reliability.</p>
<p><img fetchpriority="high" decoding="async" class="aligncenter  wp-image-11621" src="https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg" alt="Image illustrating a temperature control unit TCU for the injection molding of composite materials." width="685" height="382" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg 1376w, https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1-300x167.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1-1024x572.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1-768x429.jpg 768w" sizes="(max-width: 685px) 100vw, 685px" /></p>
<p><em>Solutions proposed by Tempco</em><br />
Basically, our preferred solution would have been to replace the on/off solenoid valve with a ½&#8221; or ¾&#8221; <strong>proportional/modulating valve</strong>, allowing for gradual cooling control. However, the ASCON temperature controller installed in the client’s TCU does not support a modulating valve, and retrofitting one would be highly invasive.<br />
The practical, immediately implementable solution was to install a <strong>manual valve on the cooling water inlet</strong> to throttle the flow to a minimum, paired with a solenoid valve properly sized upon this reduced flow rate.<br />
For future units, it is therefore advisable to install a <strong>heat exchanger sized according to the actual power requirements</strong>, equipped with a solenoid valve matched to the minimum necessary flow rate.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/10729/ipe-new-website-for-thermoregulation-services-and-technologies-specialist/" title="Permanent link to IPE, new website for thermoregulation services and technologies specialist">IPE, new website for thermoregulation services and technologies specialist</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10952/efficiency-and-operational-continuity-original-spare-parts-make-the-difference/" title="Permanent link to Efficiency and operational continuity: original spare parts make the difference">Efficiency and operational continuity: original spare parts make the difference</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8691/service-efficiency-heat-exchangers-and-enjoy-august/" title="Permanent link to Service, efficiency, heat exchangers and… Enjoy August!">Service, efficiency, heat exchangers and… Enjoy August!</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11008/scheduled-service-a-smart-choice-for-the-lifecycle-of-tempco-thermal-machines/" title="Permanent link to Scheduled service, a smart choice for the lifecycle of Tempco thermal machines">Scheduled service, a smart choice for the lifecycle of Tempco thermal machines</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8144/heat-exchangers-regeneration-it-is-not-always-necessary-to-replace-gaskets/" title="Permanent link to Heat exchangers regeneration, it is not always necessary to replace gaskets">Heat exchangers regeneration, it is not always necessary to replace gaskets</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11620/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus/">Injection molding and heating element failure in temperature control units (TCUs)</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Immersion plates exchangers for process tanks cooling</title>
		<link>https://www.tempco.it/blog/en/11595/immersion-plates-exchangers-for-process-tanks-cooling/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 06 Nov 2026 12:07:53 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Energy Saving]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heat recovery]]></category>
		<category><![CDATA[Immerged heat exchangers]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[custom]]></category>
		<category><![CDATA[design flexibility]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[electroplating]]></category>
		<category><![CDATA[energy recovery]]></category>
		<category><![CDATA[galvanic baths]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heat recovery]]></category>
		<category><![CDATA[HVAC]]></category>
		<category><![CDATA[immersion heat exchangers]]></category>
		<category><![CDATA[immersion plates]]></category>
		<category><![CDATA[marine sector]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[port operations]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[tcoil]]></category>
		<category><![CDATA[textile]]></category>
		<category><![CDATA[wastewater]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11595</guid>

					<description><![CDATA[<p>Immersion plate heat exchangers for cooling process tanks in the textile and synthetic fiber manufacturing sector; these units offer high heat-trasfer efficiency and a highly flexible construction, allowing TCOIL exchangers to fit challenging space constraints.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11595/immersion-plates-exchangers-for-process-tanks-cooling/">Immersion plates exchangers for process tanks cooling</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>For the <strong>cooling of process tanks</strong>, Tempco’s TCOIL series of <a href="https://en.tempco.it/solutions-en/heat-exchangers/dimple-jacket/" target="_blank" rel="noopener"><strong>immersion plate heat exchangers</strong></a> offers a highly efficient solution. <strong><a href="https://www.tempco.it/blog/en/11467/cutting-oil-cooling-with-immersion-heat-exchangers/" target="_blank" rel="noopener">TCOIL immersion exchangers</a></strong> provide great <strong>flexibility in terms of footprint</strong>, as the exchangers can be sized according to both the required thermal duty and the available space.</p>
<p>This is illustrated by a recent project for a client in the <strong><a href="https://www.tempco.it/blog/en/10163/free-flow-exchangers-for-thermal-energy-recovery-in-the-textile-industry/" target="_blank" rel="noopener">textile</a> and synthetic fiber production sector</strong>, who needed to cool two process tanks, each 60 cm wide with a usable length of 4 meters. Cooling is achieved via plates immersed directly in the tanks through a water-to-water heat transfer process. Cooling water is supplied at 8°C to maintain the process water at a temperature between 20°C and 40°C, depending on production requirements.</p>
<p><img decoding="async" class="aligncenter  wp-image-11597" src="https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-scambiatori-a-piastre-a-immersione-raffreddamento-vasche-di-processo-industria-tessile-1.jpg" alt="Illustrative image of a production process in the textile industry, related to the application of immersion plate heat exchangers for cooling process tanks." width="650" height="434" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-scambiatori-a-piastre-a-immersione-raffreddamento-vasche-di-processo-industria-tessile-1.jpg 1361w, https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-scambiatori-a-piastre-a-immersione-raffreddamento-vasche-di-processo-industria-tessile-1-300x200.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-scambiatori-a-piastre-a-immersione-raffreddamento-vasche-di-processo-industria-tessile-1-1024x682.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/11/Tempco-scambiatori-a-piastre-a-immersione-raffreddamento-vasche-di-processo-industria-tessile-1-768x512.jpg 768w" sizes="(max-width: 650px) 100vw, 650px" /></p>
<p><strong>Space constraints</strong> were carefully evaluated, further complicated by the presence of drain pipes at the bottom of the tanks. Consequently, the plate was positioned on the bottom of the tank floor but raised by a few centimeters, allowing for heat exchange across both sides of the plate. A wide range of industries can benefit significantly from immersion plate heat exchanger cooling solutions—from <strong>textiles</strong> and <a href="https://www.tempco.it/blog/en/8266/tcoil-plate-exchangers-in-galvanic-baths/" target="_blank" rel="noopener"><strong>electroplating</strong></a> to surface treatments and <a href="https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/" target="_blank" rel="noopener"><strong>heat recovery from wastewater</strong></a>.</p>
<p>In parallel, Tempco has indeed developed another application using TCOIL immersion plate heat exchangers for a client in the <strong>maritime/port sector</strong>. This project applies the same principle used for the textile industry client, but utilizes <strong>wastewater as a heat transfer source</strong> for winter heating and summer cooling, leveraging a heat-recovery-based cooling solution.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/10163/free-flow-exchangers-for-thermal-energy-recovery-in-the-textile-industry/" title="Permanent link to Free flow exchangers for thermal energy recovery in the textile industry">Free flow exchangers for thermal energy recovery in the textile industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/" title="Permanent link to Wastewater heat recovery with custom immersion plate heat exchangers">Wastewater heat recovery with custom immersion plate heat exchangers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9378/tcoil-plate-heat-exchangers-in-renewables-applications/" title="Permanent link to TCOIL plate heat exchangers in renewables applications">TCOIL plate heat exchangers in renewables applications</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10493/free-flow-heat-exchangers-in-pulp-and-paper-and-plastics-industries/" title="Permanent link to Free flow heat exchangers in pulp and paper and plastics industries">Free flow heat exchangers in pulp and paper and plastics industries</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11595/immersion-plates-exchangers-for-process-tanks-cooling/">Immersion plates exchangers for process tanks cooling</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Seawater and low temperatures: material selection for plate heat exchangers</title>
		<link>https://www.tempco.it/blog/en/11584/seawater-and-low-temperatures-material-selection-for-plate-heat-exchangers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 29 Oct 2026 10:33:02 +0000</pubDate>
				<category><![CDATA[corrosion]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[connections]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[corrosione]]></category>
		<category><![CDATA[diffusion bonding]]></category>
		<category><![CDATA[duplex steel]]></category>
		<category><![CDATA[EPDM]]></category>
		<category><![CDATA[gaskets]]></category>
		<category><![CDATA[guarnizioni]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[high pressures]]></category>
		<category><![CDATA[low temperatures]]></category>
		<category><![CDATA[material selection]]></category>
		<category><![CDATA[mechanical calculation]]></category>
		<category><![CDATA[PCHE]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[printed circuit exchangers]]></category>
		<category><![CDATA[seawater]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[subsea]]></category>
		<category><![CDATA[titanium]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11584</guid>

					<description><![CDATA[<p>Applications involving seawater and low temperatures require the use of titanium or duplex steel for plate heat exchangers—including both the plates and the connections—along with specialized mechanical design calculations. PCHE units represent an excellent solution.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11584/seawater-and-low-temperatures-material-selection-for-plate-heat-exchangers/">Seawater and low temperatures: material selection for plate heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Temperature control applications involving <a href="https://en.tempco.it/solutions-en/heat-exchangers/" target="_blank" rel="noopener"><strong>plate heat exchangers</strong></a> in <a href="https://www.tempco.it/blog/en/9340/from-water-to-energy-baglietto-unfolds-the-future-of-zero-emission-yachting/" target="_blank" rel="noopener"><strong>seawater</strong></a> and low-temperature environments present a technical challenge frequently recurrent, primarily regarding the choice of materials—specifically, the use of either <strong>titanium or duplex steel</strong> is mandatory.</p>
<p>For projects where a plate heat exchanger will come into contact with seawater, with flanged connections, both the <strong>plates and the connections must be made of titanium or duplex steel</strong>. The unit’s frame (body) is typically constructed from carbon steel, fitted with EPDM gaskets, to withstand operating conditions characterized by high corrosivity and <strong>low temperatures, reaching as low as -40 °C</strong>.</p>
<p><img decoding="async" class="aligncenter  wp-image-11585" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-scambiatori-PCHE-subsea-scelta-materiali-1.jpg" alt="An image illustrating a Printed Circuit Heat Exchanger (PCHE); its high structural strength makes this type of exchanger an interesting choice for demanding applications in subsea environments." width="660" height="577" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-scambiatori-PCHE-subsea-scelta-materiali-1.jpg 1191w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-scambiatori-PCHE-subsea-scelta-materiali-1-300x262.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-scambiatori-PCHE-subsea-scelta-materiali-1-1024x896.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-scambiatori-PCHE-subsea-scelta-materiali-1-768x672.jpg 768w" sizes="(max-width: 660px) 100vw, 660px" /></p>
<p>Furthermore, selecting the appropriate plate heat exchanger for low-temperature conditions necessitates a <strong>dedicated mechanical calculation</strong>. Low temperatures alter the required pressure class and the necessary material thickness. For such operating conditions, <a href="https://en.tempco.it/solutions-en/heat-exchangers/pche-exchangers/" target="_blank" rel="noopener"><strong>printed circuit heat exchangers (PCHE)</strong></a> represent an compelling solution, as they offer exceptional mechanical and structural strength. Their construction process—utilizing <a href="https://www.tempco.it/blog/en/9807/diffusion-bonding-for-high-performance-plate-heat-exchangers/" target="_blank" rel="noopener"><strong>diffusion bonding</strong></a> (solid-state welding)—ensures excellent structural integrity for the plate pack, making PCHE units highly suitable for demanding applications, such as <a href="https://www.tempco.it/blog/en/10523/different-traditional-and-advanced-solutions-for-interstage-cooling-in-compressors/" target="_blank" rel="noopener"><strong>gas compression</strong></a> or <a href="https://www.tempco.it/blog/en/10409/pche-heat-exchanger-in-offshore-oilgas-cooling-applications/" target="_blank" rel="noopener">subsea environments</a>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11182/brazed-plate-heat-exchangers-in-hydraulic-power-plants/" title="Permanent link to Brazed plate heat exchangers in hydraulic power plants">Brazed plate heat exchangers in hydraulic power plants</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9827/chillers-exchangers-and-separators-for-biogas-treatment/" title="Permanent link to Chillers, exchangers and separators for biogas treatment">Chillers, exchangers and separators for biogas treatment</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9675/double-standby-exchangers-for-efficient-oil-cooling-in-power-generation/" title="Permanent link to Double standby exchangers for efficient oil cooling in power generation">Double standby exchangers for efficient oil cooling in power generation</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/5122/metal-corrosion-in-thermal-machines-2/" title="Permanent link to Metal corrosion in thermal machines">Metal corrosion in thermal machines</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8581/special-plate-heat-exchangers-for-oilgas-applications/" title="Permanent link to Special plate heat exchangers for oil&#038;gas applications">Special plate heat exchangers for oil&#038;gas applications</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11584/seawater-and-low-temperatures-material-selection-for-plate-heat-exchangers/">Seawater and low temperatures: material selection for plate heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>All-stainless steel brazed plate heat exchangers for high water purity</title>
		<link>https://www.tempco.it/blog/en/11536/all-stainless-steel-brazed-plate-heat-exchangers-for-high-water-purity/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 09 Oct 2026 09:48:35 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[corrosion]]></category>
		<category><![CDATA[Corrosione]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[all-stainless steel]]></category>
		<category><![CDATA[brazed plate heat exchangers]]></category>
		<category><![CDATA[chemical industry]]></category>
		<category><![CDATA[contamination]]></category>
		<category><![CDATA[corrosione]]></category>
		<category><![CDATA[deionized water]]></category>
		<category><![CDATA[demineralized water]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[electrolyzers]]></category>
		<category><![CDATA[energy]]></category>
		<category><![CDATA[food industry]]></category>
		<category><![CDATA[fuel cells]]></category>
		<category><![CDATA[Full inox]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[hydrogen]]></category>
		<category><![CDATA[Kaori]]></category>
		<category><![CDATA[leaching]]></category>
		<category><![CDATA[pharmaceutical]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[semiconductors]]></category>
		<category><![CDATA[solid temperature]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11536</guid>

					<description><![CDATA[<p>Tempco TCBS series all-stainless steel brazed plate exchangers for applications requiring high water purity and corrosion resistance—handling demineralized water in the hydrogen industry (fuel cells and electrolyzers), semiconductor manufacturing, and the food, chemical and pharma. </p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11536/all-stainless-steel-brazed-plate-heat-exchangers-for-high-water-purity/">All-stainless steel brazed plate heat exchangers for high water purity</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Using copper in <a href="https://en.tempco.it/solutions-en/heat-exchangers/brazed-plate/" target="_blank" rel="noopener"><strong>brazed plate heat exchangers</strong></a> for deionized and demineralized water applications can lead to fluid contamination and damage to the exchanger itself. For heating and cooling applications requiring <strong>high water purity and exceptional corrosion resistance</strong>, the solution is to choose all-stainless steel brazed plate heat exchangers.</p>
<p>To meet this need, Tempco offers the new <strong>TCBS series of brazed plate heat exchangers made entirely of stainless steel</strong> and featuring brazing with a copper-free stainless steel alloy. These exchangers are therefore the ideal choice for a wide range of applications—from the <a href="https://www.tempco.it/blog/en/11151/brazed-plate-exchangers-for-hydrogen-applications-electrolysis-and-fuel-cells/" target="_blank" rel="noopener"><strong>hydrogen industry</strong></a> in <a href="https://www.tempco.it/blog/en/9951/heat-exchangers-hydrogen-cooling-and-fuel-cells/" target="_blank" rel="noopener"><strong>fuel cells</strong></a> and electrolyzers, to <strong>semiconductor</strong> manufacturing, the<strong> food industry</strong>, the <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" target="_blank" rel="noopener"><strong>chemical and pharmaceutical</strong></a> sectors, and any processes requiring the handling of pure or demineralized water.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11537" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1.jpg" alt="Image showing the Tempco TCBS all-stainless steel brazed plate heat exchangers series for applications requiring high water purity." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /></p>
<p>The absence of copper in the brazing of these heat exchangers <strong>eliminates the risk of copper ion contamination</strong>; such ions can be released upon contact with demineralized water through a process known as <strong>leaching</strong>, which can eventually lead to perforation of the heat exchanger. Compared to traditional gasketed plate heat exchangers, brazed models allow for <strong>stable operating pressures</strong>—standard <strong>versions rated at 10 bar</strong> (A) or <strong>20 bar</strong> (B)—along with a wide operating temperature range and superior corrosion resistance. These factors contribute to high heat transfer efficiency, long service life, and an excellent cost-to-performance ratio. Their greater compactness compared to shell-and-tube solutions also makes the TCBS <strong>ideal for applications with limited space</strong>.</p>
<p>The Tempco TCBS series of all-stainless steel brazed plate heat exchangers is <strong>available in seven sizes</strong> to meet diverse production needs, ranging from low to high flow rates. <strong>Custom configurations and connection options</strong> are also available upon request. The TCBS series corresponds to the &#8220;S &#8211; All Stainless BPHE&#8221; series manufactured by Kaori Heat Treatment Co., Ltd. (Taiwan).</p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="wp-image-11539 aligncenter" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1.jpg" alt="Image showing the Tempco TCBS all-stainless steel brazed plate heat exchanger series for applications requiring high water purity, specifically involving deionized and demineralized water." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /><br />
<img loading="lazy" decoding="async" class="aligncenter  wp-image-11541" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1.jpg" alt="Image showing the Tempco TCBS all-stainless steel brazed plate heat exchanger series for applications requiring high water purity and high corrosion resistance." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /><br />
<img loading="lazy" decoding="async" class="aligncenter  wp-image-11543" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1.jpg" alt="Image showing the models and sizes of the Tempco TCBS all-stainless steel brazed plate heat exchanger series for applications requiring high water purity and high corrosion resistance." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /></p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11545" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1.jpg" alt="Image showing the application sectors for the Tempco TCBS all-stainless steel brazed plate heat exchanger series, designed for applications requiring high water purity and high corrosion resistance." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /></p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8581/special-plate-heat-exchangers-for-oilgas-applications/" title="Permanent link to Special plate heat exchangers for oil&#038;gas applications">Special plate heat exchangers for oil&#038;gas applications</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/7833/fouling-factor-in-heat-exchangers-and-nanocoatings/" title="Permanent link to Fouling factor in heat exchangers and nanocoatings">Fouling factor in heat exchangers and nanocoatings</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11182/brazed-plate-heat-exchangers-in-hydraulic-power-plants/" title="Permanent link to Brazed plate heat exchangers in hydraulic power plants">Brazed plate heat exchangers in hydraulic power plants</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10896/precision-and-hygiene-in-stainless-steel-for-pharma-and-food-thermoregulation/" title="Permanent link to Precision and hygiene in stainless steel for pharma and food thermoregulation">Precision and hygiene in stainless steel for pharma and food thermoregulation</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9827/chillers-exchangers-and-separators-for-biogas-treatment/" title="Permanent link to Chillers, exchangers and separators for biogas treatment">Chillers, exchangers and separators for biogas treatment</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11536/all-stainless-steel-brazed-plate-heat-exchangers-for-high-water-purity/">All-stainless steel brazed plate heat exchangers for high water purity</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Brazed plate heat exchangers for liquid cooling: high-efficiency computing density in data centers</title>
		<link>https://www.tempco.it/blog/en/11504/brazed-plate-heat-exchangers-for-liquid-cooling-high-efficiency-computing-density-in-data-centers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 24 Sep 2026 14:37:26 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Energy Saving]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[AI]]></category>
		<category><![CDATA[BPHE]]></category>
		<category><![CDATA[CDU]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[chip]]></category>
		<category><![CDATA[cold plates]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[data center]]></category>
		<category><![CDATA[dielectric fluids]]></category>
		<category><![CDATA[direct to chip]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[energy saving]]></category>
		<category><![CDATA[evaporation]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[GPU]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heat transfer]]></category>
		<category><![CDATA[HPC]]></category>
		<category><![CDATA[immersion cooling]]></category>
		<category><![CDATA[in rack]]></category>
		<category><![CDATA[in row]]></category>
		<category><![CDATA[liquid cooling]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[PUE]]></category>
		<category><![CDATA[server]]></category>
		<category><![CDATA[solid sustainability]]></category>
		<category><![CDATA[sustainability]]></category>
		<category><![CDATA[Tempco Green]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11504</guid>

					<description><![CDATA[<p>Tempco brazed plate heat exchangers (BPHEs) in CDUs used for liquid cooling, employing cold plates technology or direct hardware immersion in dielectric fluids, for the sustainable cooling of high-power-density data centers.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11504/brazed-plate-heat-exchangers-for-liquid-cooling-high-efficiency-computing-density-in-data-centers/">Brazed plate heat exchangers for liquid cooling: high-efficiency computing density in data centers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>In <a href="https://www.tempco.it/blog/en/11110/high-efficiency-exchangers-for-liquid-cooling-in-ai-hpc-data-centers/" target="_blank" rel="noopener"><strong>data centers</strong></a>, the shift from air cooling to <strong>liquid cooling</strong> techniques offers significant advantages regarding energy savings and superior cooling efficiency. It enables increased computing density and, overall, improves the sustainability of large-scale high-performance computing infrastructures.</p>
<p>Today, the rapid and continuous rise in heat amounts from chips renders traditional air-conditioning systems inadequate. <strong>Tempco BPHE</strong> <a href="https://en.tempco.it/solutions-en/heat-exchangers/brazed-plate/" target="_blank" rel="noopener"><strong>brazed plate heat exchangers</strong></a>—also available in an all-stainless-steel version—are the technological heart of this shift to liquid cooling; they act as a key technological enabler that brings sustainability to data centers by <strong>reducing PUE (Power Usage Effectiveness)</strong> while simultaneously allowing for increased rack density.</p>
<p>The superior performance of liquid cooling stems primarily from the fact that liquids are more efficient than air at transferring heat, allowing for <strong>more effective heat dissipation and lower energy consumption</strong> for the same amounts of heat removed. This makes it possible to reliably manage the higher power densities typical of AI and HPC applications—delivering high performance in a more eco-friendly manner. Furthermore, liquid cooling allows for highly targeted and precise cooling, as liquids are easier to direct toward specific components than air. The cooling ecosystem is completed by <a href="https://en.tempco.it/solutions-en/industrial-coolers-electroradiators/" target="_blank" rel="noopener"><strong>free-cooling</strong></a> systems and <a href="https://en.tempco.it/solutions-en/chillers/" target="_blank" rel="noopener"><strong>chillers</strong></a> located outside the data center; these dissipate the heat extracted from the servers and conveyed outdoors via the BPHE exchangers.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-11505" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1.jpg" alt="Image illustrating the applications of Tempco BPHE (brazed plate heat exchangers) in CDUs for liquid cooling in high-power-density data centers." width="721" height="721" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1.jpg 1361w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1-300x300.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1-1024x1024.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1-150x150.jpg 150w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1-768x768.jpg 768w" sizes="auto, (max-width: 721px) 100vw, 721px" /></p>
<p>Tempco supplies brazed plate heat exchangers (BPHEs) for <strong>data center liquid cooling</strong>, offering models and versions suitable for every type of liquid cooling method, regardless of the system architecture. Their highly compact design allows for easy integration into the <a href="https://www.tempco.it/blog/en/11354/brazed-plate-heat-exchangers-for-cdus-in-liquid-cooling-for-data-centers/" target="_blank" rel="noopener"><strong>Coolant Distribution Units (CDUs)</strong></a> found in liquid cooling systems, thereby saving space within the installation. Tempco’s process expertise and capability to manufacture integrated solutions—such as complete skid systems—offer a further advantage to data center manufacturers and operators, enabling the creation of compact, comprehensive solutions that are easy to install and integrate into computing infrastructures.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11507" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1.jpg" alt="" width="761" height="431" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1.jpg 1701w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1-300x170.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1-1024x580.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1-768x435.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1-1536x870.jpg 1536w" sizes="auto, (max-width: 761px) 100vw, 761px" /></p>
<p>Tempco’s brazed plate exchangers are suitable for use in both <strong>cold plates and immersion cooling systems</strong>—the two main liquid cooling methods used in data centers. The product range covers a wide power spectrum, offering models from 5 to 200 kW for in-rack CDUs and units capable of handling 500 kW to 3 MW for stand-alone in-row CDUs.</p>
<p>Tempco’s range of brazed plate heat exchangers includes models designed for <strong>Direct-to-Chip (DTC) liquid cooling architectures</strong> that utilize <strong>cold plates</strong>. Cold plates technology employs conductive metal plates applied directly to high-power electronic components, such as GPUs and CPUs. The generated heat is absorbed by a coolant circulating through microchannel structures within the cold plates. In this liquid cooling system, the <strong>CDU acts as a hydraulic safety barrier</strong>: here, the overheated fluid arriving from the cold plates flows to the BPHE; once cooled, it is recirculated into the loop, remaining isolated from the external cooling water circuit (free cooler, chiller, and evaporative towers) and thereby protecting the IT equipment from potential contamination.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11509" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-scaled.jpg" alt="Image illustrating in-row and in-rack CDU liquid cooling architectures for data centers, showing the integrated placement of the Tempco BPHE brazed plate heat exchanger." width="760" height="407" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-scaled.jpg 2560w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-300x161.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-1024x548.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-768x411.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-1536x822.jpg 1536w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-2048x1096.jpg 2048w" sizes="auto, (max-width: 760px) 100vw, 760px" /></p>
<p>Tempco offers brazed plate heat exchangers for CDUs in liquid cooling solutions using cold plates for both <strong>&#8220;in-rack&#8221; architectures</strong>—where the exchangers&#8217; compact size allows for easy CDU integration within server cabinets—and <strong>&#8220;in-row&#8221; setups</strong>, featuring standalone CDU cabinets separate from individual IT racks that can serve up to 10 servers simultaneously.</p>
<p>The product range also includes brazed plate heat exchangers (BPHEs) for <strong>immersion liquid cooling solutions</strong>. Unlike cold plates—which are applied directly to high-power chips and components, typically requiring hybrid solutions that rely on air cooling for other parts of the computing infrastructure—immersion liquid cooling involves submerging all hardware in dedicated tanks containing special <a href="https://www.tempco.it/blog/en/9628/liquid-cooling-and-immersion-exchangers-in-data-centers/" target="_blank" rel="noopener"><strong>dielectric fluids</strong></a>. This ensures uniform cooling across all components, thereby eliminating hot spots.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11511" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1.jpg" alt="Image illustrating an immersion liquid cooling architecture for data centers featuring Tempco BPHE brazed plate heat exchangers.
" width="760" height="427" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1.jpg 1701w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1-300x169.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1-1024x576.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1-768x432.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1-1536x863.jpg 1536w" sizes="auto, (max-width: 760px) 100vw, 760px" /></p>
<p>Finally, whether used with cold plates or immersion cooling,Tempco offers brazed plate exchangers optimized for <strong>single-phase liquid cooling</strong> systems, where the coolant (often a water-glycol mixture) remains in the liquid phase throughout the thermal cycle, as well as for <strong>two-phase cooling systems</strong>, where the coolant boils upon contact with the cold plate or the overheated servers. This two-phase approach offers superior cooling efficiency, making it ideal for high workloads and ultra-high-density racks; however, it requires a more complex cooling circuit to manage evaporation phases and ensure precise pressure and temperature control.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11354/brazed-plate-heat-exchangers-for-cdus-in-liquid-cooling-for-data-centers/" title="Permanent link to Brazed plate heat exchangers for CDUs in liquid cooling for data centers">Brazed plate heat exchangers for CDUs in liquid cooling for data centers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10747/pche-heat-exchangers-for-the-energy-transition-market/" title="Permanent link to PCHE heat exchangers for the energy transition market">PCHE heat exchangers for the energy transition market</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9796/tempco-green-a-new-thermal-energy-for-a-solid-sustainability/" title="Permanent link to Tempco Green, a new thermal energy for a solid sustainability">Tempco Green, a new thermal energy for a solid sustainability</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9404/present-and-future-of-thermal-energy-in-the-second-e-book-tempco/" title="Permanent link to Present and future of thermal energy in the second e-book Tempco">Present and future of thermal energy in the second e-book Tempco</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11504/brazed-plate-heat-exchangers-for-liquid-cooling-high-efficiency-computing-density-in-data-centers/">Brazed plate heat exchangers for liquid cooling: high-efficiency computing density in data centers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Brazed plate heat exchangers: when immediate availability makes the difference</title>
		<link>https://www.tempco.it/blog/en/11476/brazed-plate-heat-exchangers-when-immediate-availability-makes-the-difference/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 10 Sep 2026 09:19:07 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[Maintenance]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[Service]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[brazed plate]]></category>
		<category><![CDATA[compact footprint]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[exchangers]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heat transfer]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[immediate delivery]]></category>
		<category><![CDATA[plant downtime]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[stainless steel]]></category>
		<category><![CDATA[stock]]></category>
		<category><![CDATA[warehouse]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11476</guid>

					<description><![CDATA[<p>Brazed plate heat exchangers available for immediate delivery from Tempco to meet urgent needs and replacement requirements; the Italian warehouse stock of over 1,000 units is crucial for preventing plant and production downtime.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11476/brazed-plate-heat-exchangers-when-immediate-availability-makes-the-difference/">Brazed plate heat exchangers: when immediate availability makes the difference</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Market lead times for the delivery of <a href="https://en.tempco.it/solutions-en/heat-exchangers/brazed-plate/" target="_blank" rel="noopener"><strong>brazed plate heat exchangers</strong></a> have recently increased significantly, often stretching into weeks or months. At <strong>Tempco</strong>, we have taken a different approach: we <strong>stock over 1,000 brazed plate heat exchangers in Italy</strong>, ready for immediate shipment, to meet the majority of common requests without delay.</p>
<p><a href="https://www.tempco.it/blog/en/11182/brazed-plate-heat-exchangers-in-hydraulic-power-plants/" target="_blank" rel="noopener"><strong>Brazed plate heat exchangers</strong></a> consist of stainless steel plates joined via <strong>copper or nickel brazing</strong>. They offer maximum heat transfer efficiency within a <strong>compact footprint</strong>, making them ideal for heat transfer where space is limited. Furthermore, the brazing process creates a plate pack with superior mechanical strength, enabling operation at <strong>higher pressures</strong> and across <strong>wider temperature ranges</strong>.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11477" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-pronta-consegna-1.jpg" alt="Image showing a range of brazed plate heat exchangers—a type of unit Tempco offers for immediate delivery, thanks to an Italian warehouse stock of over 1,000 units." width="551" height="550" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-pronta-consegna-1.jpg 610w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-pronta-consegna-1-300x300.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-pronta-consegna-1-150x150.jpg 150w" sizes="auto, (max-width: 551px) 100vw, 551px" /></p>
<p>Immediate availability applies to models with standard connections and ports up to 2&#8243;. By focusing on the most common sizes and configurations, Tempco can <strong>respond promptly to urgent needs, replacement requests, and equipment downtime</strong>. In such situations, the quick delivery of a heat exchanger makes the difference between getting a system back up and running immediately vs suffering costly shutdowns.</p>
<p>Let’s discuss your needs<br />
If you have a system to complete, a machine that is down, or wish to get ahead of market price increases, please <strong><a href="https://en.tempco.it/contacts/" target="_blank" rel="noopener">contact us</a> with the required size and connection specifications</strong>; we will check immediate availability and shipping times together.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8691/service-efficiency-heat-exchangers-and-enjoy-august/" title="Permanent link to Service, efficiency, heat exchangers and… Enjoy August!">Service, efficiency, heat exchangers and… Enjoy August!</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8550/preventive-maintenance-for-heat-exchangers-efficiency/" title="Permanent link to Preventive maintenance for heat exchangers efficiency">Preventive maintenance for heat exchangers efficiency</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10192/importance-of-maintenance-in-plate-heat-exchangers-and-replacement-of-gaskets/" title="Permanent link to Importance of maintenance in plate heat exchangers and replacement of gaskets">Importance of maintenance in plate heat exchangers and replacement of gaskets</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/" title="Permanent link to Tempco&#8217;s spare parts ordering guide for plate heat exchangers">Tempco&#8217;s spare parts ordering guide for plate heat exchangers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8449/mechanical-and-engineering-advantages-of-plate-exchangers-in-hydraulics/" title="Permanent link to Mechanical and engineering advantages of plate exchangers in hydraulics">Mechanical and engineering advantages of plate exchangers in hydraulics</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11476/brazed-plate-heat-exchangers-when-immediate-availability-makes-the-difference/">Brazed plate heat exchangers: when immediate availability makes the difference</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Wastewater heat recovery with custom immersion plate heat exchangers</title>
		<link>https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 24 Jul 2026 10:27:22 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[corrosion]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Energy Saving]]></category>
		<category><![CDATA[Fouling factor]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heat recovery]]></category>
		<category><![CDATA[Immerged heat exchangers]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[AISI 316L]]></category>
		<category><![CDATA[beverage]]></category>
		<category><![CDATA[chemical]]></category>
		<category><![CDATA[custom]]></category>
		<category><![CDATA[energy efficiency]]></category>
		<category><![CDATA[energy saving]]></category>
		<category><![CDATA[food]]></category>
		<category><![CDATA[fouling]]></category>
		<category><![CDATA[fouling factor]]></category>
		<category><![CDATA[heat recovery]]></category>
		<category><![CDATA[heat transfer]]></category>
		<category><![CDATA[immersion plate heat exchangers]]></category>
		<category><![CDATA[parboiled rice]]></category>
		<category><![CDATA[parboiling]]></category>
		<category><![CDATA[pharmaceutical]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[preheating]]></category>
		<category><![CDATA[purification]]></category>
		<category><![CDATA[retrofit]]></category>
		<category><![CDATA[rice production]]></category>
		<category><![CDATA[solid sustainability]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[sustainability]]></category>
		<category><![CDATA[Tempco Green]]></category>
		<category><![CDATA[turbulent flow]]></category>
		<category><![CDATA[wastewater]]></category>
		<category><![CDATA[water treatment]]></category>
		<category><![CDATA[well water]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11443</guid>

					<description><![CDATA[<p>Tempco custom immersion plate heat exchangers arrays designed for energy-saving applications—specifically heat recovery from wastewater used for well-water preheating—installed in an equalization tank for parboiled rice production.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/">Wastewater heat recovery with custom immersion plate heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Tempco</strong> has implemented an interesting new energy-saving application using <strong>custom <a href="https://en.tempco.it/solutions-en/heat-exchangers/dimple-jacket/" target="_blank" rel="noopener">immersion plate heat exchangers</a></strong> for a client in the <strong>parboiled rice production</strong> sector. Specifically, for this project, Tempco manufactured and supplied t<strong>wo arrays of custom immersion heat exchangers</strong>—each consisting of 20 plates measuring 2500 x 500 mm, made of <strong>AISI 316L stainless steel</strong> with a 100 mm plate spacing. This custom application is of significant interest to energy managers and technical specialists across various industries, as it is ideally suited for other <a href="https://www.tempco.it/blog/en/10896/precision-and-hygiene-in-stainless-steel-for-pharma-and-food-thermoregulation/" target="_blank" rel="noopener"><strong>food and beverage</strong></a> production processes, as well as the <a href="https://www.tempco.it/blog/en/5453/dimple-plate-jacket-from-chemical-and-beyond/" target="_blank" rel="noopener"><strong>chemical</strong></a> and <a href="https://www.tempco.it/blog/en/8156/monofluid-thermoregulation-in-pharma-group-for-api-production/" target="_blank" rel="noopener"><strong>pharmaceutical</strong></a> sectors.</p>
<p>In this specific case, the <a href="https://www.tempco.it/blog/en/8796/energy-recovery-with-immersion-exchangers-in-industrial-laundries/" target="_blank" rel="noopener"><strong>immersion plate heat exchanger</strong></a> arrays have been installed in the <strong>equalization tank</strong>, which receives the <strong>wastewater generated by the parboiling process</strong>—consisting primarily of water used to soak the paddy rice. The purpose of the custom immersion plate heat exchanger is to <strong>recover heat from the wastewater</strong>, yielding a dual benefit: first, the recovered heat preheats well water circulating within the plates to the highest possible temperature, resulting in significant <strong>energy savings by reducing steam consumption</strong>. Second, the heat transfer process cools the wastewater before it is sent to the purification plant, providing a substantial advantage for the biological treatment processes taking place there.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-11444" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1.jpg" alt="Image showing arrays of custom immersion plate heat exchangers in an equalization tank, designed for energy saving through heat recovery from wastewater generated during rice production." width="701" height="419" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1.jpg 1284w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1-300x179.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1-1024x612.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1-768x459.jpg 768w" sizes="auto, (max-width: 701px) 100vw, 701px" /></p>
<p>The system was implemented as <strong>custom and in retrofit</strong>, utilizing existing structures within the client’s equalization tank. Specifically, the <strong>existing agitators</strong> were leveraged to maintain a fluid velocity of ≥0.1 m/s, generating turbulence that enhances heat transfer efficiency. Furthermore, the immersion heat exchanger arrays were installed by anchoring them to decommissioned aeration pipes (2.0 x 2.6 m).</p>
<p>Overall, the system will enable significant energy savings for the client, <strong>recovering approximately 174 kW of heat</strong> (150,000 kcal/h) and saving 1,500–1,700 tonnes of steam per year. Material selection for the heat exchanger plates was also critical; <strong>AISI 316L stainless steel</strong> was chosen to ensure <a href="https://www.tempco.it/blog/en/10552/revamping-and-corrosion-protection-of-cooling-radiators-in-marine-installation/" target="_blank" rel="noopener"><strong>corrosion resistance</strong></a> (handling wastewater with a pH of 3.7–3.9 with no critical chloride levels). <a href="https://www.tempco.it/blog/en/9511/fouling-factor-each-type-of-exchanger-has-his-own/" target="_blank" rel="noopener"><strong>Fouling</strong></a> caused by starches in the wastewater was accounted for using a conservative fouling factor (4E-4 m²K/W). Finally, given the intermittent nature of the wastewater flow—process wastewater is discharged every two hours, though a minimum volume is always maintained in the tank—performance was calculated at 70% of the theoretical maximum to determine the system&#8217;s ROI.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11595/immersion-plates-exchangers-for-process-tanks-cooling/" title="Permanent link to Immersion plates exchangers for process tanks cooling">Immersion plates exchangers for process tanks cooling</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9796/tempco-green-a-new-thermal-energy-for-a-solid-sustainability/" title="Permanent link to Tempco Green, a new thermal energy for a solid sustainability">Tempco Green, a new thermal energy for a solid sustainability</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9733/hydrogen-and-thermal-management-for-the-green-energy-industry/" title="Permanent link to Hydrogen and thermal management for the Green Energy Industry">Hydrogen and thermal management for the Green Energy Industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8999/sustainability-and-heat-exchangers-a-whole-month-dedicated-to-renewables/" title="Permanent link to Sustainability and heat exchangers, a whole month dedicated to Renewables">Sustainability and heat exchangers, a whole month dedicated to Renewables</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/">Wastewater heat recovery with custom immersion plate heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Five key data for heat exchangers sizing</title>
		<link>https://www.tempco.it/blog/en/11414/five-key-data-for-heat-exchangers-sizing/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 10 Jul 2026 09:34:55 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[Manualistica]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[engineering]]></category>
		<category><![CDATA[exchangers]]></category>
		<category><![CDATA[flow rate]]></category>
		<category><![CDATA[fouling]]></category>
		<category><![CDATA[gas]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[pressure]]></category>
		<category><![CDATA[pressure drop]]></category>
		<category><![CDATA[sizing]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[Tempco]]></category>
		<category><![CDATA[temperature]]></category>
		<category><![CDATA[thermal calculation]]></category>
		<category><![CDATA[tutorial]]></category>
		<category><![CDATA[viscosity]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11414</guid>

					<description><![CDATA[<p>Five thermal calculation parameters required to size heat exchangers, including fluid inlet and outlet temperatures, flow rates, and fluid pressure - the latter being critical for gases.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11414/five-key-data-for-heat-exchangers-sizing/">Five key data for heat exchangers sizing</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Tempco</strong> has created a clear, concise tutorial to simplify the selection of <strong>data needed to size <a href="https://en.tempco.it/solutions-en/heat-exchangers/" target="_blank" rel="noopener">heat exchangers</a></strong>. When performing <a href="https://www.tempco.it/blog/en/8801/five-fingers-rule-and-heat-exchangers/" target="_blank" rel="noopener">thermal calculations for heat exchangers</a>, it is not necessary to provide every data point listed in the document for completeness &#8211; only a specific subset is required.</p>
<p>In fact, as indicated in the documentation, just <strong>five of the listed data are necessary</strong> and sufficient: the &#8216;must-have&#8217; data &#8211; essential for initiating the sizing process- are those required for the <strong>thermal calculation</strong>:</p>
<ul>
<li>Primary fluid inlet and outlet temperatures</li>
<li>Primary fluid flow rate</li>
<li>Secondary fluid inlet and outlet temperatures</li>
<li>Secondary fluid flow rate</li>
<li>Fluid pressure (crucial in the case of gases)</li>
</ul>
<p><strong>Capacity</strong> is another important factor for the thermal sizing of the exchanger; however, if the other five data are available, capacity can be calculated from them.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11415" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN.jpg" alt="Image illustrating the essential and useful data for sizing heat exchangers." width="700" height="384" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN.jpg 1862w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-300x164.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-1024x561.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-768x421.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-1536x841.jpg 1536w" sizes="auto, (max-width: 700px) 100vw, 700px" /></p>
<p>The other data listed under the heading &#8220;DATA FOR HEAT EXCHANGERS DESIGN AND CONSTRUCTION&#8221; are <strong>useful for a more precise and comprehensive design</strong> but are not essential for an initial thermal calculation:</p>
<ul>
<li>Fluid types</li>
<li>Max. operating temperature</li>
<li>Max. operating pressure</li>
<li>Oversizing % (margin)</li>
<li>Allowable pressure drops (primary and secondary)</li>
<li>Fluid viscosity</li>
<li>Fluid specific weight</li>
<li>Heat transfer coefficient</li>
<li>Fouling factor</li>
</ul>
<p>In summary, to begin the sizing process, it is <strong>essential to provide at least five of the listed thermal parameters</strong> &#8211; including <strong>pressure if a gas is involved</strong>. The remaining data help refine the unit&#8217;s design specifications but are not required at the initial stage. It is important to note that for <strong>special fluids</strong>, you must <a href="https://en.tempco.it/contacts/" target="_blank" rel="noopener"><strong>contact Tempco directly</strong></a>, as specified in the document.</p>
<p>FIVE FINGERS RULE<br />
<iframe loading="lazy" title="Conoscete la regola delle 5 dita?" width="750" height="422" src="https://www.youtube.com/embed/Tw3VHtWNgp4?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11417" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1019" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-1056x1536.jpg 1056w" sizes="auto, (max-width: 700px) 100vw, 700px" /> <img loading="lazy" decoding="async" class="aligncenter  wp-image-11419" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1018" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-1056x1536.jpg 1056w" sizes="auto, (max-width: 700px) 100vw, 700px" /> <img loading="lazy" decoding="async" class="aligncenter  wp-image-11421" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1018" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-1056x1536.jpg 1056w" sizes="auto, (max-width: 700px) 100vw, 700px" /> <img loading="lazy" decoding="async" class="aligncenter  wp-image-11423" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1018" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-1056x1536.jpg 1056w" sizes="auto, (max-width: 700px) 100vw, 700px" /></p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8801/five-fingers-rule-and-heat-exchangers/" title="Permanent link to Five fingers rule and heat exchangers">Five fingers rule and heat exchangers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/" title="Permanent link to Tempco&#8217;s spare parts ordering guide for plate heat exchangers">Tempco&#8217;s spare parts ordering guide for plate heat exchangers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8550/preventive-maintenance-for-heat-exchangers-efficiency/" title="Permanent link to Preventive maintenance for heat exchangers efficiency">Preventive maintenance for heat exchangers efficiency</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8569/fluids-flow-in-heat-exchangers-counter-flow-vs-parallel-flow/" title="Permanent link to Fluid’s flow in heat exchangers, counter-flow vs. parallel-flow">Fluid’s flow in heat exchangers, counter-flow vs. parallel-flow</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8999/sustainability-and-heat-exchangers-a-whole-month-dedicated-to-renewables/" title="Permanent link to Sustainability and heat exchangers, a whole month dedicated to Renewables">Sustainability and heat exchangers, a whole month dedicated to Renewables</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11414/five-key-data-for-heat-exchangers-sizing/">Five key data for heat exchangers sizing</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Brazed plate heat exchangers for CDUs in liquid cooling for data centers</title>
		<link>https://www.tempco.it/blog/en/11354/brazed-plate-heat-exchangers-for-cdus-in-liquid-cooling-for-data-centers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 05 Jun 2026 11:04:43 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Energy Saving]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[AI]]></category>
		<category><![CDATA[artificial intelligence]]></category>
		<category><![CDATA[brazed plate]]></category>
		<category><![CDATA[CDU]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[chillers]]></category>
		<category><![CDATA[chip]]></category>
		<category><![CDATA[chips]]></category>
		<category><![CDATA[cold plates]]></category>
		<category><![CDATA[computing power]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[data center]]></category>
		<category><![CDATA[dielectric fluids]]></category>
		<category><![CDATA[electronic components]]></category>
		<category><![CDATA[electronics]]></category>
		<category><![CDATA[energy efficiency]]></category>
		<category><![CDATA[heat dissipation]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[HPC]]></category>
		<category><![CDATA[liquid cooling]]></category>
		<category><![CDATA[PUE]]></category>
		<category><![CDATA[rack]]></category>
		<category><![CDATA[racks]]></category>
		<category><![CDATA[servers]]></category>
		<category><![CDATA[solid sustainability]]></category>
		<category><![CDATA[sustainability]]></category>
		<category><![CDATA[Tempco Green]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11354</guid>

					<description><![CDATA[<p>Tempco's range of brazed plate heat exchangers for CDUs in high-performance data center liquid cooling systems, for superior cooling efficiency and improved sustainability in AI and HPC applications.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11354/brazed-plate-heat-exchangers-for-cdus-in-liquid-cooling-for-data-centers/">Brazed plate heat exchangers for CDUs in liquid cooling for data centers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Tempco</strong> offers a complete range of <a href="https://en.tempco.it/solutions-en/heat-exchangers/brazed-plate/" target="_blank" rel="noopener"><strong>brazed plate heat exchangers</strong></a> designed and developed specifically for the <strong>cooling needs of <a href="https://www.tempco.it/blog/en/11110/high-efficiency-exchangers-for-liquid-cooling-in-ai-hpc-data-centers/" target="_blank" rel="noopener">data centers</a></strong>, computing infrastructures in rapidly growing demand to meet the needs of new <strong>AI and HPC applications</strong>.</p>
<p>Among the cooling solutions offered by Tempco for data centers, particular attention is paid to the most innovative <a href="https://www.tempco.it/blog/en/9628/liquid-cooling-and-immersion-exchangers-in-data-centers/" target="_blank" rel="noopener"><strong>liquid cooling technologies</strong></a>, which offer greater efficiency in dissipating heat generated by chips &#8211; and therefore better temperature regulation &#8211; thanks to the <strong>superior thermal conductivity of liquids</strong> compared to traditional air cooling solutions. Tempco brazed plate exchangers therefore serve as a <strong>key technology for CDUs</strong> &#8211; Coolant Distribution Units &#8211; used in the liquid cooling of high-performance data centers, a strategic path to <strong>reduce the environmental impact of data centers</strong>, increase their sustainability and improve energy consumption efficiency (PUE, power usage effectiveness).</p>
<p>The improved thermal management made possible by liquid cooling also allows data centers to <strong>operate at higher power densities</strong> while maintaining high performance and reliability.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-11355" src="https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-liquid-cooling-data-center-scambiatori-1.jpg" alt="Illustrative image of Tempco's brazed plate heat exchangers ecosystem for CDUs in liquid coolig applications for high-performance data centers." width="580" height="326" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-liquid-cooling-data-center-scambiatori-1.jpg 1843w, https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-liquid-cooling-data-center-scambiatori-1-300x168.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-liquid-cooling-data-center-scambiatori-1-1024x575.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-liquid-cooling-data-center-scambiatori-1-768x431.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-liquid-cooling-data-center-scambiatori-1-1536x863.jpg 1536w" sizes="auto, (max-width: 580px) 100vw, 580px" /><br />
Liquid cooling for servers and electronic devices uses <a href="https://www.tempco.it/blog/en/10415/dielectric-fluids-in-data-center-and-electronics-components-cooling/" target="_blank" rel="noopener"><strong>dielectric fluids</strong></a>, suitable for direct contact with chips and electronic equipment, in the case of <strong>direct immersion cooling</strong>, or for <strong>cold plates applications</strong>. Cold plates are special components used in the liquid cooling of electronic components, made of metals with high thermal conductivity (typically copper or aluminum). The chip or electronic component that overheats is attached directly to the cold plate, and the heat is transferred to it by conduction. Inside, the coolant flows through special microchannel structures, which greatly increase the contact surface with the overheated metal. The liquid then absorbs the heat and, via a small pump, is pushed out of the cold plate towards a heat exchanger or <a href="https://en.tempco.it/solutions-en/chillers/" target="_blank" rel="noopener"><strong>chiller</strong></a>.</p>
<p>In addition to the superior heat dissipation efficiency of the heat generated by servers, liquid cooling also offers <strong>another key advantage: compactness</strong>, allowing for the creation of high-density computing structures in data centers while <strong>saving installation space</strong>. The Tempco range of brazed exchangers for liquid cooling in data centers therefore offers very compact dimensions, which allow for <strong>easy integration into CDUs</strong> inside racks or in-row architectures, which can serve up to 10 racks.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11504/brazed-plate-heat-exchangers-for-liquid-cooling-high-efficiency-computing-density-in-data-centers/" title="Permanent link to Brazed plate heat exchangers for liquid cooling: high-efficiency computing density in data centers">Brazed plate heat exchangers for liquid cooling: high-efficiency computing density in data centers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11570/liquid-cooling-and-high-efficiency-heat-recovery-in-data-centers/" title="Permanent link to Liquid cooling and high efficiency heat recovery in data centers">Liquid cooling and high efficiency heat recovery in data centers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11110/high-efficiency-exchangers-for-liquid-cooling-in-ai-hpc-data-centers/" title="Permanent link to High efficiency exchangers for liquid cooling in AI/HPC data centers">High efficiency exchangers for liquid cooling in AI/HPC data centers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/7431/how-to-achieve-energy-saving-in-data-center-cooling/" title="Permanent link to How to achieve energy saving in data center cooling">How to achieve energy saving in data center cooling</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/7393/the-big-rise-of-immersion-liquid-cooling-in-data-center-market/" title="Permanent link to The big rise of immersion liquid cooling in data center market">The big rise of immersion liquid cooling in data center market</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11354/brazed-plate-heat-exchangers-for-cdus-in-liquid-cooling-for-data-centers/">Brazed plate heat exchangers for CDUs in liquid cooling for data centers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tempco&#8217;s spare parts ordering guide for plate heat exchangers</title>
		<link>https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 22 May 2026 09:50:22 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[Maintenance]]></category>
		<category><![CDATA[Manualistica]]></category>
		<category><![CDATA[Manutenzione]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[Service]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[assistance]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[exchangers]]></category>
		<category><![CDATA[gaskets]]></category>
		<category><![CDATA[guarnizioni]]></category>
		<category><![CDATA[heat transfer]]></category>
		<category><![CDATA[heat transfer plates]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[maintenance]]></category>
		<category><![CDATA[manuals]]></category>
		<category><![CDATA[manutenzione]]></category>
		<category><![CDATA[original spare parts]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[reconditioning]]></category>
		<category><![CDATA[revamping]]></category>
		<category><![CDATA[safety]]></category>
		<category><![CDATA[service]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[spare parts]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11313</guid>

					<description><![CDATA[<p>Tempco's manual for the correct selection of spare parts for heat transfer plates and gaskets in plate heat exchangers, essential in order to ensure maximum efficiency, operational safety, and longevity.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/">Tempco&#8217;s spare parts ordering guide for plate heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>To ensure high thermal performance and long-lasting durability, choosing<strong> original spare parts</strong> for <a href="https://en.tempco.it/solutions-en/heat-exchangers/" target="_blank" rel="noopener"><strong>plate heat exchangers</strong></a> is essential. To support users in the correct selection of original spare parts for <strong>plates and gaskets</strong>, Tempco has developed a dedicated Manual that allows customers to always ensure the highest levels of efficiency and operational safety for their thermal management plants.</p>
<p>The <a href="https://en.tempco.it/assistance/service-exchangers/" target="_blank" rel="noopener"><strong>Tempco Service</strong></a> team provides technical support for component identification, compatibility verification, and the supply of appropriate spare parts. First, it is necessary to <strong>identify the exchanger model</strong>, which is the basis for any spare parts request.</p>
<p>The <strong>exchanger model</strong> can be found from:</p>
<ul>
<li>Identification plate attached to the exchanger</li>
<li>Technical drawings or thermal calculation sheets</li>
<li>Tempco supply documents</li>
</ul>
<p>It is also helpful to provide:</p>
<ul>
<li>Number of plates installed</li>
<li>Gasket type</li>
<li>Year of supply or serial number</li>
</ul>
<p>The two tables below therefore offer valuable support when requesting <strong>spare parts for heat transfer plates and gaskets</strong>.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-11314" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-scaled.jpg" alt="Image showing the diagram for selecting spare parts for heat exchange plates in plate heat exchangers." width="651" height="302" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-scaled.jpg 2560w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-300x139.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-1024x475.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-768x357.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-1536x713.jpg 1536w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-2048x951.jpg 2048w" sizes="auto, (max-width: 651px) 100vw, 651px" /></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-11316" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-scaled.jpg" alt="Image showing the diagram for selecting spare parts for gaskets in plate heat exchangers." width="650" height="383" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-scaled.jpg 2560w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-300x177.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-1024x603.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-768x452.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-1536x904.jpg 1536w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-2048x1206.jpg 2048w" sizes="auto, (max-width: 650px) 100vw, 650px" /></p>
<p>Finally, some helpful further tips:</p>
<ul>
<li>Send clear photos of the plates and gaskets for quick identification.</li>
<li>Indicate the process fluid and operating conditions.</li>
<li>Tempco can provide <a href="https://www.tempco.it/blog/en/10096/plate-heat-exchangers-revamping-in-steel-mill/" target="_blank" rel="noopener">plate reconditioning and regeneration</a> with leak testing.</li>
<li>Keeping a <strong>spare set of gaskets</strong> reduces system downtime.</li>
<li>Observe recommended tightening torque values when reassembling.</li>
</ul>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11329" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1.jpg" alt="Image showing the Tempco Guide to selecting spare parts for plate heat exchangers." width="650" height="947" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1.jpg 1168w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1-703x1024.jpg 703w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1-1055x1536.jpg 1055w" sizes="auto, (max-width: 650px) 100vw, 650px" /></p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11332" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1.jpg" alt="Image showing the Tempco Guide to selecting spare parts for plate heat exchangers, plates, and gaskets." width="650" height="585" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1.jpg 1168w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1-300x270.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1-1024x921.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1-768x691.jpg 768w" sizes="auto, (max-width: 650px) 100vw, 650px" /></p>
<p>&nbsp;</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/10952/efficiency-and-operational-continuity-original-spare-parts-make-the-difference/" title="Permanent link to Efficiency and operational continuity: original spare parts make the difference">Efficiency and operational continuity: original spare parts make the difference</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10192/importance-of-maintenance-in-plate-heat-exchangers-and-replacement-of-gaskets/" title="Permanent link to Importance of maintenance in plate heat exchangers and replacement of gaskets">Importance of maintenance in plate heat exchangers and replacement of gaskets</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10729/ipe-new-website-for-thermoregulation-services-and-technologies-specialist/" title="Permanent link to IPE, new website for thermoregulation services and technologies specialist">IPE, new website for thermoregulation services and technologies specialist</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8691/service-efficiency-heat-exchangers-and-enjoy-august/" title="Permanent link to Service, efficiency, heat exchangers and… Enjoy August!">Service, efficiency, heat exchangers and… Enjoy August!</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8144/heat-exchangers-regeneration-it-is-not-always-necessary-to-replace-gaskets/" title="Permanent link to Heat exchangers regeneration, it is not always necessary to replace gaskets">Heat exchangers regeneration, it is not always necessary to replace gaskets</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/">Tempco&#8217;s spare parts ordering guide for plate heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
