<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:media="http://search.yahoo.com/mrss/"
	>

<channel>
	<title>Free cooler Archivi - Tempco Blog</title>
	<atom:link href="https://www.tempco.it/blog/category/free-cooler/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.tempco.it/blog/category/free-cooler/</link>
	<description>Soluzioni per l&#039;energia termica</description>
	<lastBuildDate>Fri, 06 Dec 2024 10:54:03 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.8</generator>
	<item>
		<title>Raffreddamento dei bruciatori nei sistemi di ossitaglio delle acciaierie</title>
		<link>https://www.tempco.it/blog/10324/raffreddamento-dei-bruciatori-nei-sistemi-di-ossitaglio-delle-acciaierie/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 06 Dec 2024 10:35:17 +0000</pubDate>
				<category><![CDATA[dissipatori]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[acciaieria]]></category>
		<category><![CDATA[billette]]></category>
		<category><![CDATA[bramme]]></category>
		<category><![CDATA[bruciatori]]></category>
		<category><![CDATA[dissipazione]]></category>
		<category><![CDATA[efficienza]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[manutenzione]]></category>
		<category><![CDATA[materiali ferrosi]]></category>
		<category><![CDATA[ossitaglio]]></category>
		<category><![CDATA[raffreddamento]]></category>
		<category><![CDATA[semilavorati]]></category>
		<category><![CDATA[sicurezza]]></category>
		<category><![CDATA[siderurgia]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[surriscaldamento]]></category>
		<category><![CDATA[usura]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=10324</guid>

					<description><![CDATA[<p>Il raffreddamento dei sistemi di ossitaglio nelle acciaierie, necessari per rientrare nelle dimensioni standard nella produzione di billette e bramme, può impiegare il free cooling per la dissipazione a livelli non molto spinti di temperatura coinvolti.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/10324/raffreddamento-dei-bruciatori-nei-sistemi-di-ossitaglio-delle-acciaierie/">Raffreddamento dei bruciatori nei sistemi di ossitaglio delle acciaierie</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Nelle <a href="https://www.tempco.it/blog/7534/raffreddamento-adiabatico-nella-trafilatura-dellacciaio/"><strong>acciaierie</strong></a>, gli impianti di produzione di <strong>semilavorati siderurgici</strong>, come <strong>billette e bramme</strong>, richiedono la presenza di un <strong>sistema di taglio per rientrare nelle dimensioni standard</strong> di spedizione per i carichi di materiali ferrosi.</p>
<p><img decoding="async" class="aligncenter wp-image-10325" src="https://www.tempco.it/blog/wp-content/uploads/2024/12/Tempco-raffreddamento-sistemi-ossitaglio-billette-bramme-free-cooling.jpg" alt="Tempco raffreddamento sistemi ossitaglio billette bramme free cooling" width="650" height="365" srcset="https://www.tempco.it/blog/wp-content/uploads/2024/12/Tempco-raffreddamento-sistemi-ossitaglio-billette-bramme-free-cooling.jpg 922w, https://www.tempco.it/blog/wp-content/uploads/2024/12/Tempco-raffreddamento-sistemi-ossitaglio-billette-bramme-free-cooling-300x169.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2024/12/Tempco-raffreddamento-sistemi-ossitaglio-billette-bramme-free-cooling-768x431.jpg 768w" sizes="(max-width: 650px) 100vw, 650px" /></p>
<p>I <strong>sistemi di raffreddamento dei bruciatori</strong> sono cruciali negli <strong>impianti di ossitaglio di bramme e billette</strong> per diverse ragioni:</p>
<ol>
<li><strong>Prevenzione del surriscaldamento</strong>: i bruciatori funzionano a temperature estremamente elevate. Senza un adeguato raffreddamento, potrebbero surriscaldarsi, causando danni strutturali o guasti.</li>
<li><strong>Mantenimento dell&#8217;efficienza</strong>: un bruciatore raffreddato in modo appropriato opera in modo più efficiente. Il raffreddamento impedisce che le temperature troppo alte alterino le prestazioni, mantenendo un taglio preciso e costante.</li>
<li><strong>Sicurezza</strong>: il raffreddamento riduce il rischio di incendi o esplosioni dovute al surriscaldamento, migliorando la sicurezza dell&#8217;intero impianto.</li>
<li><strong>Durata dei componenti</strong>: il raffreddamento regolare riduce l&#8217;usura dei componenti del bruciatore, prolungando la vita utile dell&#8217;impianto e riducendo i costi di manutenzione.</li>
</ol>
<p>Il raffreddamento avviene per ovvi motivi ad acqua, con dissipazione che spesso può essere effettuata mediante l&#8217;utilizzo di <a href="https://www.tempco.it/soluzioni/raffreddatori-industriali-elettroradiatori/" target="_blank" rel="noopener"><strong>free-cooler</strong></a>, in quanto i <strong>livelli di temperatura non sono particolarmente spinti</strong>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/10142/free-cooling-in-cosa-consiste-e-quando-conviene-in-termini-di-roi/" title="Permanent link to Free cooling, in cosa consiste e quando conviene in termini di ROI">Free cooling, in cosa consiste e quando conviene in termini di ROI</a>  </li>
<li> <a href="https://www.tempco.it/blog/6329/raffreddamento-adiabatico-in-free-cooling-a-plast-2018%e2%80%a8/" title="Permanent link to Raffreddamento adiabatico in free cooling a Plast 2018 ">Raffreddamento adiabatico in free cooling a Plast 2018 </a>  </li>
<li> <a href="https://www.tempco.it/blog/8176/quando-implementare-il-free-cooling-e-davvero-conveniente/" title="Permanent link to Quando implementare il free cooling è davvero conveniente?">Quando implementare il free cooling è davvero conveniente?</a>  </li>
<li> <a href="https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/" title="Permanent link to Rinnovabili e energy saving con free cooler e torri evaporative">Rinnovabili e energy saving con free cooler e torri evaporative</a>  </li>
<li> <a href="https://www.tempco.it/blog/8183/raffreddamento-ridondato-per-bruciatori-nel-riciclo-batterie/" title="Permanent link to Raffreddamento ridondato per bruciatori nel riciclo batterie">Raffreddamento ridondato per bruciatori nel riciclo batterie</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/10324/raffreddamento-dei-bruciatori-nei-sistemi-di-ossitaglio-delle-acciaierie/">Raffreddamento dei bruciatori nei sistemi di ossitaglio delle acciaierie</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2024/12/Tempco-raffreddamento-sistemi-ossitaglio-billette-bramme-free-cooling-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2024/12/Tempco-raffreddamento-sistemi-ossitaglio-billette-bramme-free-cooling.jpg" medium="image">
			<media:title type="html">Tempco raffreddamento sistemi ossitaglio billette bramme free cooling</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2024/12/Tempco-raffreddamento-sistemi-ossitaglio-billette-bramme-free-cooling-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Free cooling, in cosa consiste e quando conviene in termini di ROI</title>
		<link>https://www.tempco.it/blog/10142/free-cooling-in-cosa-consiste-e-quando-conviene-in-termini-di-roi/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 05 Jul 2024 09:47:52 +0000</pubDate>
				<category><![CDATA[aerorefrigeranti]]></category>
		<category><![CDATA[Chiller]]></category>
		<category><![CDATA[Cooler]]></category>
		<category><![CDATA[dissipatori]]></category>
		<category><![CDATA[dry-cooler]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[radiatori]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[Refrigeratori]]></category>
		<category><![CDATA[Risparmio energetico]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[compressori]]></category>
		<category><![CDATA[dry cooler]]></category>
		<category><![CDATA[efficienza]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[gruppi frigoriferi]]></category>
		<category><![CDATA[raffreddamento]]></category>
		<category><![CDATA[risparmio energetico]]></category>
		<category><![CDATA[ROI]]></category>
		<category><![CDATA[solid sustainability]]></category>
		<category><![CDATA[Tempco Green]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=10142</guid>

					<description><![CDATA[<p>Un sistema di free cooling nel raffreddamento di processo con gruppi frigoriferi consente un importante risparmio energetico se l'impianto si trova in un Paese dal clima freddo o dove la stagione fredda è particolarmente lunga.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/10142/free-cooling-in-cosa-consiste-e-quando-conviene-in-termini-di-roi/">Free cooling, in cosa consiste e quando conviene in termini di ROI</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Si parla molto di <a href="https://www.tempco.it/blog/8176/quando-implementare-il-free-cooling-e-davvero-conveniente/"><strong>free cooling</strong></a>, a diversi livelli, ed è un&#8217;applicazione veramente interessante. Abbiamo a che fare con il free cooling quando disponiamo di un sistema di <strong>raffreddamento a basso consumo energetico</strong>.</p>
<p>Ma di fatto, quando è possibile installare un sistema di free cooling? Spesso ci sono industrie di processo che richiedono attività di raffreddamento all&#8217;interno del loro processo produttivo con <strong>temperature dell&#8217;acqua di raffreddamento piuttosto basse</strong>. Diciamo <strong>10-15 o anche 20° C</strong>. Sono requisiti che una <a href="https://www.tempco.it/soluzioni/torri-evaporative/" target="_blank" rel="noopener"><strong>torre evaporativa</strong></a> non può soddisfare durante la stagione calda, e nemmeno un sistema con <strong>radiatore</strong>, che sfrutta la dissipazione del calore mediante l&#8217;aria.<br />
E&#8217; pertanto necessario utilizzare dei <a href="https://www.tempco.it/soluzioni/gruppi-frigoriferi/" target="_blank" rel="noopener"><strong>gruppi frigoriferi</strong></a>.</p>
<p>Ma ci sono condizioni ambientali, durante la stagione fredda, o anche durante le ore più fresche della giornata, in cui un gruppo frigorifero è sostanzialmente uno spreco, perché potendo sfruttare le condizioni ambientali favorevolmente fredde in questi frangenti, potrebbe bastare un <a href="https://www.tempco.it/soluzioni/raffreddatori-industriali-elettroradiatori/" target="_blank" rel="noopener"><strong>dry cooler</strong></a>, cioè un dissipatore. Che tipo di vantaggi porta un sistema di free cooling?</p>
<p>A livello di costi si tratta chiaramente di qualcosa in più che dobbiamo implementare all&#8217;interno dell&#8217;impianto di refrigerazione. Sostanzialmente, si deve accompagnare un refrigeratore con un sistema di freecooling, un oggetto che durante la stagione estiva probabilmente non servirà. Ma durante la stagione invernale, <strong>consentirà di spegnere i chiller</strong>. Questo di fatto comporta un <strong>importante risparmio energetico</strong>.</p>
<p><iframe loading="lazy" title="FREE COOLING cosa è e quando conviene..." width="750" height="422" src="https://www.youtube.com/embed/x-9ofpcwtr8?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>Facendo un bilancio grossolano, con un gruppo frigorifero con COP 3 (Coefficiente di Prestazione) per ottenere una <strong>dissipazione di 90 kW termici</strong> abbiamo un <strong>consumo di energia elettrica di 30 kW</strong>, più o meno. Di questi 30 kW, 24-25 kW vengono generalmente consumati dai <strong>compressori di refrigerazione</strong> necessari per raffreddare l&#8217;acqua. Utilizzando un sistema di free cooling, questi 24-25 kW svaniranno perché rimarranno solamente i kW impiegati per la <strong>ventilazione</strong>, chiaramente, e i kW dedicati alla <strong>pompa di circolazione dell&#8217;acqua</strong>. È quindi chiaro che avremo un notevole risparmio energetico dissipando la stessa quantità di energia termica.</p>
<p>Adesso possiamo anche fare un paio di valutazioni per capire quale potrebbe essere il <strong>ritorno dell&#8217;investimento di un impianto di free cooling</strong>. Diciamo che ci sono moltissime applicazioni in cui il free cooling è sicuramente un&#8217;ottima soluzione. Dipende chiaramente dalla latitudine: più l&#8217;<strong>impianto è installato in una regione fredda</strong> o che ha una stagione fredda più lunga, più sarà facile avere un ROI più breve della soluzione free cooling.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/8176/quando-implementare-il-free-cooling-e-davvero-conveniente/" title="Permanent link to Quando implementare il free cooling è davvero conveniente?">Quando implementare il free cooling è davvero conveniente?</a>  </li>
<li> <a href="https://www.tempco.it/blog/8233/raffreddamento-preferenza-tra-chiller-torri-e-dry-cooler/" title="Permanent link to Raffreddamento, preferenza tra chiller, torri e dry cooler">Raffreddamento, preferenza tra chiller, torri e dry cooler</a>  </li>
<li> <a href="https://www.tempco.it/blog/6329/raffreddamento-adiabatico-in-free-cooling-a-plast-2018%e2%80%a8/" title="Permanent link to Raffreddamento adiabatico in free cooling a Plast 2018 ">Raffreddamento adiabatico in free cooling a Plast 2018 </a>  </li>
<li> <a href="https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/" title="Permanent link to Rinnovabili e energy saving con free cooler e torri evaporative">Rinnovabili e energy saving con free cooler e torri evaporative</a>  </li>
<li> <a href="https://www.tempco.it/blog/10165/free-cooling-adiabatico-per-energy-saving-in-impianto-chimico/" title="Permanent link to Free cooling adiabatico per energy saving in impianto chimico">Free cooling adiabatico per energy saving in impianto chimico</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/10142/free-cooling-in-cosa-consiste-e-quando-conviene-in-termini-di-roi/">Free cooling, in cosa consiste e quando conviene in termini di ROI</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Raffreddamento a liquido e scambiatori a immersione dei data center</title>
		<link>https://www.tempco.it/blog/9619/raffreddamento-a-liquido-e-per-immersione-dei-data-center/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 27 Oct 2023 10:26:14 +0000</pubDate>
				<category><![CDATA[adiabatico]]></category>
		<category><![CDATA[data center]]></category>
		<category><![CDATA[dissipatori]]></category>
		<category><![CDATA[dry-cooler]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[Risparmio energetico]]></category>
		<category><![CDATA[Scambiatori ad immersione]]></category>
		<category><![CDATA[Scambiatori di calore]]></category>
		<category><![CDATA[AI]]></category>
		<category><![CDATA[ambiente]]></category>
		<category><![CDATA[chip]]></category>
		<category><![CDATA[crunch di dati]]></category>
		<category><![CDATA[efficienza]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[gestione termica]]></category>
		<category><![CDATA[GPU]]></category>
		<category><![CDATA[IDTechEx]]></category>
		<category><![CDATA[impatto ambientale]]></category>
		<category><![CDATA[Nvidia]]></category>
		<category><![CDATA[potenza computazionale]]></category>
		<category><![CDATA[raffreddamento]]></category>
		<category><![CDATA[raffreddamento a liquido]]></category>
		<category><![CDATA[raffreddamento adiabatico]]></category>
		<category><![CDATA[raffreddamento per immersione]]></category>
		<category><![CDATA[risparmio energetico]]></category>
		<category><![CDATA[scambiatori a immersione]]></category>
		<category><![CDATA[scambiatori di calore]]></category>
		<category><![CDATA[server]]></category>
		<category><![CDATA[solid sustainability]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[Solidsustainability]]></category>
		<category><![CDATA[sostenibilità]]></category>
		<category><![CDATA[tcoil]]></category>
		<category><![CDATA[Tempco Green]]></category>
		<category><![CDATA[TempcoGreen]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=9619</guid>

					<description><![CDATA[<p>Continua la crescita del raffreddamento a liquido e per immersione dei data center, con temperature di lavoro che consentono l'impiego di soluzioni di free cooling, per far fronte all'incremento della potenza termica dei chip.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/9619/raffreddamento-a-liquido-e-per-immersione-dei-data-center/">Raffreddamento a liquido e scambiatori a immersione dei data center</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Un interessante studio di <a href="https://www.idtechex.com/it" target="_blank" rel="noopener"><strong>IDTechEx</strong></a> porta un aggiornamento sul trend di crescita delle soluzioni di <a href="https://www.tempco.it/blog/8646/raffreddamento-a-liquido-in-data-center-e-high-performance-computing/" target="_blank" rel="noopener"><strong>raffreddamento a liquido per i data center</strong></a>. Particolarmente illuminante è il dato riportato relativo al <strong>fatturato dei data center</strong> del secondo trimestre 2023 di <strong>Nvidia</strong>, che rispetto allo stesso periodo dell&#8217;anno precedente ha registrato un <strong>incremento del +141%</strong>, toccando la cifra record di <strong>10,32 miliardi di dollari</strong>. L’aumento su base annua è del 171%.</p>
<p>La crescita nella domanda di potenza computazionale nei data center pone un <strong>problema relativo all’impatto ambientale</strong> di queste strutture. Sempre Nvidia nel 2022 ha annunciato un nuovo <strong>piano per <a href="https://www.tempco.it/blog/8698/data-center-raddoppiano-gli-investimenti-con-attenzione-ai-temi-esg/" target="_blank" rel="noopener">ridurre il consumo energetico</a> dei data center</strong>, per il crunch di enormi quantità di dati o per addestramento di modelli AI. L’azienda ha in particolare sviluppato <strong>innovative schede raffreddate a liquido</strong>, che consumano fino al 30% in meno rispetto a quelle raffreddate ad aria.</p>
<p>Con l’<strong>incremento della potenza termica dei chip</strong>, infatti, il tradizionale raffreddamento ad aria non è più sufficiente a soddisfare i requisiti di raffreddamento delle nuove applicazioni. In questo quadro, la previsione per i prossimi anni di IDTechEx è per una <strong>forte crescita e adozione del <a href="https://www.tempco.it/blog/7381/londa-globale-del-liquid-cooling-nei-data-center/" target="_blank" rel="noopener">raffreddamento a liquido dei data center</a></strong>, con un fatturato annuo che entro il 2033 supererà i <strong>900 milioni di dollari</strong>, come si legge nel report <a href="https://www.idtechex.com/it/research-report/thermal-management-for-data-centers-2023-2033-technologies-markets-and-opportunities/944" target="_blank" rel="noopener"><strong>Gestione termica per centro dati 2023-2033</strong></a>.</p>
<div id="attachment_9621" style="width: 710px" class="wp-caption aligncenter"><img aria-describedby="caption-attachment-9621" decoding="async" loading="lazy" class=" wp-image-9621" src="https://www.tempco.it/blog/wp-content/uploads/2023/10/Raffreddamento-a-liquido-data-center-IDTechEx-tabella-comparativa-liquidi-refrigeranti.jpg" alt="Raffreddamento a liquido data center IDTechEx tabella comparativa liquidi refrigeranti" width="700" height="394" srcset="https://www.tempco.it/blog/wp-content/uploads/2023/10/Raffreddamento-a-liquido-data-center-IDTechEx-tabella-comparativa-liquidi-refrigeranti.jpg 1200w, https://www.tempco.it/blog/wp-content/uploads/2023/10/Raffreddamento-a-liquido-data-center-IDTechEx-tabella-comparativa-liquidi-refrigeranti-300x169.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2023/10/Raffreddamento-a-liquido-data-center-IDTechEx-tabella-comparativa-liquidi-refrigeranti-1024x576.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2023/10/Raffreddamento-a-liquido-data-center-IDTechEx-tabella-comparativa-liquidi-refrigeranti-768x432.jpg 768w" sizes="(max-width: 700px) 100vw, 700px" /><p id="caption-attachment-9621" class="wp-caption-text">Tabella comparativa dei liquidi refrigeranti dei principali brand disponibili sul mercato per raffreddamento a liquido dei data center. Fonte IDTechEx</p></div>
<p>Nel raffreddamento a liquido, grazie al <strong>raffreddamento a liquido diretto al chip</strong> (D2C, direct-to-chip) è possibile raffreddare solo alcuni componenti, come <strong>chipset e GPU</strong>, e non schede intere. Il <strong>raffreddamento a immersione</strong> offre invece efficienza elevata e distribuita in maniera uniforme. Considerate le tipiche temperature per immersione, che vanno da 25 a 50° C come riporta la tabella sopra, Tempco vede in queste innovative applicazioni <strong>ampio spazio per il <a href="https://www.tempco.it/blog/6628/tcoil-e-free-cooling-nei-data-center-contro-il-riscaldamento-globale/" target="_blank" rel="noopener">free cooling</a></strong>, aumentandone l’efficienza. E’ pertanto possibile fornire soluzioni di dissipazione termica con dry cooler dedicati, sia a secco sia <a href="https://www.tempco.it/blog/5091/free-cooling-adiabatico/" target="_blank" rel="noopener"><strong>adiabatici</strong></a> quando la temperatura ambiente diviene più elevata. Tempco può altresì fornire <strong>soluzioni di free cooling per immersione</strong> con <a href="https://www.tempco.it/soluzioni/scambiatori-di-calore/scambiatori-calore-immersione/" target="_blank" rel="noopener"><strong>scambiatori TCOIL</strong></a>.</p>
<p><a href="https://www.idtechex.com/it/research-report/thermal-management-for-data-centers-2023-2033-technologies-markets-and-opportunities/944" target="_blank" rel="noopener"><img decoding="async" loading="lazy" class="aligncenter wp-image-9624" src="https://www.tempco.it/blog/wp-content/uploads/2023/10/IDTechEx-gestione-termica-data-center-report-raffreddamento-a-liquido.jpg" alt="IDTechEx gestione termica data center report raffreddamento a liquido" width="500" height="377" srcset="https://www.tempco.it/blog/wp-content/uploads/2023/10/IDTechEx-gestione-termica-data-center-report-raffreddamento-a-liquido.jpg 592w, https://www.tempco.it/blog/wp-content/uploads/2023/10/IDTechEx-gestione-termica-data-center-report-raffreddamento-a-liquido-300x226.jpg 300w" sizes="(max-width: 500px) 100vw, 500px" /></a></p>
<p>Va infine detto, come anche IDTechEx sottolinea, che il <strong>processo di immersione dei server nelle vasche</strong> può essere macchinoso e oggi richiede ancora un importante <strong>retrofitting dei data center esistenti basati su rack</strong>. Occorre poi considerare i <strong>costi iniziali dell’hardware</strong>, per cui IDTechEX stima che un serbatoio di raffreddamento a immersione possa costare circa 4 mila dollari. A questo va sommato il costo del <strong>liquido refrigerante per il serbatoio</strong>. Costi iniziali relativamente elevati che vengono però ampiamente ripagati nel tempo grazie al <strong>notevole risparmio energetico che si ottiene</strong>.</p>
<p>&nbsp;</p>
<p>Per restare informato ogni mese sulle ultime <strong>applicazioni di gestione dell&#8217;energia termica</strong>, iscriviti alla <a href="https://www.tempco.it/newsletter-solid-temperature/" target="_blank" rel="noopener">Newsletter &#8211; Solid Temperature di Tempco</a>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/9619/raffreddamento-a-liquido-e-per-immersione-dei-data-center/" title="Permanent link to Liquid cooling and immersion exchangers in data centers">Liquid cooling and immersion exchangers in data centers</a>  </li>
<li> <a href="https://www.tempco.it/blog/10050/data-center-green-a-ridotto-impatto-ambientale-e-scambiatori-tcoil/" title="Permanent link to Data Center green a ridotto impatto ambientale e scambiatori TCOIL">Data Center green a ridotto impatto ambientale e scambiatori TCOIL</a>  </li>
<li> <a href="https://www.tempco.it/blog/8646/raffreddamento-a-liquido-in-data-center-e-high-performance-computing/" title="Permanent link to Raffreddamento a liquido in data center e high performance computing">Raffreddamento a liquido in data center e high performance computing</a>  </li>
<li> <a href="https://www.tempco.it/blog/8698/data-center-raddoppiano-gli-investimenti-con-attenzione-ai-temi-esg/" title="Permanent link to Data center, raddoppiano gli investimenti con attenzione ai temi ESG">Data center, raddoppiano gli investimenti con attenzione ai temi ESG</a>  </li>
<li> <a href="https://www.tempco.it/blog/7428/come-risparmiare-energia-nel-raffreddamento-dei-data-center/" title="Permanent link to Come risparmiare energia nel raffreddamento dei data center">Come risparmiare energia nel raffreddamento dei data center</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/9619/raffreddamento-a-liquido-e-per-immersione-dei-data-center/">Raffreddamento a liquido e scambiatori a immersione dei data center</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2023/10/Raffreddamento-a-liquido-data-center-IDTechEx-tabella-comparativa-liquidi-refrigeranti-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2023/10/Raffreddamento-a-liquido-data-center-IDTechEx-tabella-comparativa-liquidi-refrigeranti.jpg" medium="image">
			<media:title type="html">Raffreddamento a liquido data center IDTechEx tabella comparativa liquidi refrigeranti</media:title>
			<media:description type="html">Tabella comparativa dei liquidi refrigeranti dei principali brand disponibili sul mercato per raffreddamento a liquido dei data center</media:description>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2023/10/Raffreddamento-a-liquido-data-center-IDTechEx-tabella-comparativa-liquidi-refrigeranti-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2023/10/IDTechEx-gestione-termica-data-center-report-raffreddamento-a-liquido.jpg" medium="image">
			<media:title type="html">IDTechEx gestione termica data center report raffreddamento a liquido</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2023/10/IDTechEx-gestione-termica-data-center-report-raffreddamento-a-liquido-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Macchine termiche, la regola delle quattro dita</title>
		<link>https://www.tempco.it/blog/8822/macchine-termiche-la-regola-delle-quattro-dita/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 25 Nov 2022 11:37:53 +0000</pubDate>
				<category><![CDATA[Chiller]]></category>
		<category><![CDATA[Condensatori evaporativi]]></category>
		<category><![CDATA[Condense]]></category>
		<category><![CDATA[Cooler]]></category>
		<category><![CDATA[dry-cooler]]></category>
		<category><![CDATA[Evaporatori]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[Raffreddatori evaporativi]]></category>
		<category><![CDATA[Refrigeratori]]></category>
		<category><![CDATA[Torri Evaporative]]></category>
		<category><![CDATA[bulbo umido]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[dimensionamento]]></category>
		<category><![CDATA[dry cooler]]></category>
		<category><![CDATA[dry cooling]]></category>
		<category><![CDATA[evaporazione]]></category>
		<category><![CDATA[gruppi frigoriferi]]></category>
		<category><![CDATA[progettazione]]></category>
		<category><![CDATA[raffreddamento]]></category>
		<category><![CDATA[regola delle cinque dita]]></category>
		<category><![CDATA[regola delle quattro dita]]></category>
		<category><![CDATA[riscaldamento]]></category>
		<category><![CDATA[scambiatori]]></category>
		<category><![CDATA[scambiatori di calore]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[temperatura di bulbo umido]]></category>
		<category><![CDATA[torri evaporative]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=8822</guid>

					<description><![CDATA[<p>Dopo la regola delle cinque dita, ecco la regola delle quattro dita per le macchine termiche, ovvero i quattro parametri che è necessario conoscere per dimensionare correttamente dry cooler, gruppi frigoriferi e torri evaporative. </p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8822/macchine-termiche-la-regola-delle-quattro-dita/">Macchine termiche, la regola delle quattro dita</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Dopo la <a href="https://www.tempco.it/blog/8799/regola-delle-cinque-dita-negli-scambiatori-di-calore/" target="_blank" rel="noopener"><strong>regola delle 5 dita</strong></a> per gli <a href="https://www.tempco.it/soluzioni/scambiatori-di-calore/" target="_blank" rel="noopener"><strong>scambiatori di calore</strong></a>, ovvero i cinque parametri necessari per la corretta progettazione e dimensionamento di uno scambiatore, abbiamo anche una <strong>Regola delle 4 dita</strong>, che vale invece quando abbiamo a che fare con la <strong>progettazione di macchine termiche</strong>.</p>
<p>Per macchine termiche intendiamo quindi ad esempio un <a href="https://www.tempco.it/soluzioni/raffreddatori-industriali-elettroradiatori/t-fin-idry/" target="_blank" rel="noopener"><strong>dry cooler</strong></a>, una <a href="https://www.tempco.it/soluzioni/torri-evaporative/" target="_blank" rel="noopener"><strong>torre evaporativa</strong></a> o un <a href="https://www.tempco.it/soluzioni/gruppi-frigoriferi/" target="_blank" rel="noopener"><strong>gruppo frigorifero</strong></a>. In questo caso, quattro sono infatti i dati che occorre conoscere per il <strong>corretto dimensionamento della macchina</strong>: il <strong>tipo di fluido</strong> da regolare e la sua portata; la sua <strong>temperatura in ingresso</strong>, ossia la temperatura a cui arriva dal processo; la <strong>temperatura in mandata</strong>, sarebbe a dire la temperatura richiesta in uscita dal processo; la <strong>temperatura di progetto ambientale</strong>.</p>
<p>&nbsp;</p>
<p><iframe loading="lazy" width="750" height="422" src="https://www.youtube.com/embed/oMXgdp_CFIQ?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture" allowfullscreen title="Dopo le 5 dita ecco la regola delle 4 dita"></iframe></p>
<p><strong>Temperatura ambiente</strong> che nel caso di un gruppo frigorifero è la temperatura ambiente relativa alla <strong>condensazione</strong>, per un dry cooler sarà la temperatura dell’aria ambiente che andrà a <strong>raffreddare il fluido</strong>; e per una torre evaporativa sarà infine la <a href="https://www.tempco.it/blog/7165/fondamentali-di-raffreddamento-con-torri-evaporative/" target="_blank" rel="noopener"><strong>temperatura di bulbo umido</strong></a>, parametro chiave per il ciclo di evaporazione.</p>
<p>Per restare informato ogni mese sulle ultime <strong>applicazioni di gestione dell&#8217;energia termica</strong>, iscriviti alla <a href="https://www.tempco.it/newsletter-solid-temperature/" target="_blank" rel="noopener">Newsletter &#8211; Solid Temperature di Tempco</a>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/6580/energia-termica-e-processi-industriali-una-guida/" title="Permanent link to Energia termica e processi industriali, una guida">Energia termica e processi industriali, una guida</a>  </li>
<li> <a href="https://www.tempco.it/blog/8176/quando-implementare-il-free-cooling-e-davvero-conveniente/" title="Permanent link to Quando implementare il free cooling è davvero conveniente?">Quando implementare il free cooling è davvero conveniente?</a>  </li>
<li> <a href="https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/" title="Permanent link to Rinnovabili e energy saving con free cooler e torri evaporative">Rinnovabili e energy saving con free cooler e torri evaporative</a>  </li>
<li> <a href="https://www.tempco.it/blog/8233/raffreddamento-preferenza-tra-chiller-torri-e-dry-cooler/" title="Permanent link to Raffreddamento, preferenza tra chiller, torri e dry cooler">Raffreddamento, preferenza tra chiller, torri e dry cooler</a>  </li>
<li> <a href="https://www.tempco.it/blog/8475/wind-chill-e-torri-evaporative/" title="Permanent link to Wind chill e torri evaporative">Wind chill e torri evaporative</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8822/macchine-termiche-la-regola-delle-quattro-dita/">Macchine termiche, la regola delle quattro dita</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Data center, raddoppiano gli investimenti con attenzione ai temi ESG</title>
		<link>https://www.tempco.it/blog/8698/data-center-raddoppiano-gli-investimenti-con-attenzione-ai-temi-esg/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 09 Sep 2022 11:22:11 +0000</pubDate>
				<category><![CDATA[Cooler]]></category>
		<category><![CDATA[data center]]></category>
		<category><![CDATA[dissipatori]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[Risparmio energetico]]></category>
		<category><![CDATA[Scambiatori di calore]]></category>
		<category><![CDATA[5G]]></category>
		<category><![CDATA[AI]]></category>
		<category><![CDATA[Climate Neutral Data Centre Pact]]></category>
		<category><![CDATA[cloud]]></category>
		<category><![CDATA[data centre]]></category>
		<category><![CDATA[dissipazione di calore]]></category>
		<category><![CDATA[DLA Piper]]></category>
		<category><![CDATA[efficienza]]></category>
		<category><![CDATA[elettronica]]></category>
		<category><![CDATA[energia]]></category>
		<category><![CDATA[ESG]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[impatto ambientale]]></category>
		<category><![CDATA[investimenti]]></category>
		<category><![CDATA[IoT]]></category>
		<category><![CDATA[IT]]></category>
		<category><![CDATA[Metaverso]]></category>
		<category><![CDATA[PUE]]></category>
		<category><![CDATA[raffreddamento]]></category>
		<category><![CDATA[raffreddamento a immersione]]></category>
		<category><![CDATA[raffreddamento a liquido]]></category>
		<category><![CDATA[risparmio energetico]]></category>
		<category><![CDATA[scambiatori]]></category>
		<category><![CDATA[scambiatori di calore]]></category>
		<category><![CDATA[servizi cloud]]></category>
		<category><![CDATA[sicurezza energetica]]></category>
		<category><![CDATA[solid temperature]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=8698</guid>

					<description><![CDATA[<p>Raddoppiano gli investimenti in data center nel mondo, mentre sempre più decisiva per gli investitori è l'attenzione a tematiche ESG e di sostenibilità dei data center, ambito in cui il raffreddamento a liquido a immersione offre importanti benefici di risparmio energetico.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8698/data-center-raddoppiano-gli-investimenti-con-attenzione-ai-temi-esg/">Data center, raddoppiano gli investimenti con attenzione ai temi ESG</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Lo scorso anno gli <strong>investimenti in <a href="https://www.tempco.it/blog/7428/come-risparmiare-energia-nel-raffreddamento-dei-data-center/" target="_blank" rel="noopener">data center</a></strong> nel mondo hanno segnato una crescita enorme, con un numero di transazioni che ha raggiunto le 117 unità nel 2021 in incremento annuo del 64%, e un <strong>raddoppio del valore investito</strong> che tocca i <strong>59,5 miliardi di dollari</strong> nel 2021. I dati sono contenuti nel report dello studio internazionale <a href="https://www.dlapiper.com/it/italy/" target="_blank" rel="noopener" class="broken_link"><strong>DLA Piper</strong></a>, dal rappresentativo titolo ‘<a href="https://www.dlapiper.com/it/italy/insights/publications/2022/06/rise-of-the-data-centre-global-data-centre-investment-outlook/" target="_blank" rel="noopener" class="broken_link">The meteoric rise of the data centre: key drivers behind the global demand</a>’. La crescita straordinaria sembra quindi destinata a proseguire, dal momento che nella <strong>sola prima metà del 2022</strong> le transazioni sono state già 41, per un totale di <strong>21,3 miliardi di dollari</strong>, cifra che equivale al doppio di quanto investito nello stesso periodo dello scorso anno, 10,6 miliardi di dollari.</p>
<p>Ciò che è ancora più interessante dal punto di vista di <strong>Tempco</strong> è però la crescente importanza data ai <strong>temi legati alla sicurezza eneregtica e ai fattori ESG</strong> (environment, social and governance) e di<strong> <a href="https://www.tempco.it/blog/6628/tcoil-e-free-cooling-nei-data-center-contro-il-riscaldamento-globale/" target="_blank" rel="noopener">sostenibilità ambientale</a></strong> da parte di investitori, fornitori di debito e sviluppatori di infrastrutture data center. La domanda record è naturalmente spinta dall’<strong>incremento dei dati e della richiesta di potenza di calcolo</strong>, legato alla diffusione dei <strong>servizi cloud</strong>, al <strong>crescere dell’IoT</strong> e all’uso in costante aumento dell’<strong>AI</strong>, con all’orizzonte l’avvento della <strong>connettività 5G</strong> e del <strong>Metaverso</strong>. Al contempo, cresce l’attenzione al rispetto degli standard ESG da parte istituzionale, con iniziative quali il <a href="https://www.climateneutraldatacentre.net/" target="_blank" rel="noopener"><strong>Climate Neutral Data Centre Pact</strong></a> o il ricorso a<strong><a href="https://www.tempco.it/blog/7316/misurare-lefficienza-dei-data-center-con-la-pue/" target="_blank" rel="noopener"> metriche quali il PUE</a></strong> (power usage effectiveness) nei data center, di cui abbiamo pure avuto modo di parlare in passato.</p>
<p><a href="https://www.dlapiper.com/it/italy/insights/publications/2022/06/rise-of-the-data-centre-global-data-centre-investment-outlook/" target="_blank" rel="noopener" class="broken_link"><img decoding="async" loading="lazy" class="aligncenter wp-image-8699" src="https://www.tempco.it/blog/wp-content/uploads/2022/09/Crescita-investimenti-data-center-temi-ESG-sostenibilità-DLA-Piper.jpg" alt="Crescita investimenti data center temi ESG sostenibilità DLA Piper" width="358" height="508" srcset="https://www.tempco.it/blog/wp-content/uploads/2022/09/Crescita-investimenti-data-center-temi-ESG-sostenibilità-DLA-Piper.jpg 528w, https://www.tempco.it/blog/wp-content/uploads/2022/09/Crescita-investimenti-data-center-temi-ESG-sostenibilità-DLA-Piper-211x300.jpg 211w" sizes="(max-width: 358px) 100vw, 358px" /></a></p>
<p>In questo quadro, il 94% dei soggetti interpellati dichiara che l’<strong>attenzione a tematiche ESG</strong> è cresciuta come criterio per nuovi investimenti o sviluppo di infrastrutture data center negli ultimi 24 mesi. Il 99% dichiara inoltre che questo tipo di attenzione crescerà ulteriormente nei prossimi 24 mesi. Il 35% di sviluppatori/operatori ha altresì dichiarato di aver <strong>ceduto almeno un data center negli ultimi due anni</strong> proprio a causa di <strong>problemi legati al tema ESG</strong>. Il raggiungimento di <strong>target zero emissioni</strong> diventa altrettanto rilevante: il 68% degli investitori e il 60% dei fornitori di debito e degli sviluppatori/operatori ha dichiarato che i data center nei quali hanno investito più di recente prevedono di raggiungere il target zero emissioni entro il 2030, se non hanno addirittura già completato l&#8217;obiettivo. Energia e fattori ESG figurano anche tra i principali criteri per cui gli investitori in data center sono <strong>disposti a pagare dei premi</strong>: il 70% degli sviluppatori/operatori e il 75% di investitori e fornitori di debito dichiarano che sarebbero felici di pagare un premio pur di <strong>investire in un’infrastruttura dotata di caratteristiche ESG e attenta alla sostenibilità</strong>.</p>
<p>Come abbiamo già avuto modo di trattare più volte, <strong>sostenibilità e risparmio energetico nei data center</strong> riguardano segnatamente il passaggio dal raffreddamento ad aria delle componenti IT e dell’elettronica all’utilizzo di <a href="https://www.tempco.it/blog/7381/londa-globale-del-liquid-cooling-nei-data-center/" target="_blank" rel="noopener"><strong>soluzioni di raffreddamento a liquido per immersion cooling</strong></a>. Questo rappresenta in particolare un fondamentale cambio di passo nel futuro dei data center , in direzione di infrastrutture IT più sostenibili ad impatto ambientale ridotto. Ciò è dovuto ad alcuni fattori, in primis la possibilità di impiegare <strong>fluidi di raffreddamento a temperature meno spinte</strong> verso il basso, grazie al maggior coefficiente di dissipazione del calore dei liquidi rispetto all’aria. Notevole risparmio energetico è dato quindi dall’<strong>eliminazione di ventilatori e compressori</strong> richiesti dai chiller, aprendo inoltre la strada all’utilizzo del <a href="https://www.tempco.it/soluzioni/raffreddatori-industriali-elettroradiatori/" target="_blank" rel="noopener"><strong>free cooling</strong></a>.</p>
<p>&nbsp;</p>
<p><img decoding="async" loading="lazy" class="aligncenter wp-image-8701" src="https://www.tempco.it/blog/wp-content/uploads/2022/09/DLA-Piper-crescita-investimenti-data-center-fattori-ESG.jpg" alt="DLA Piper crescita investimenti data center fattori ESG" width="750" height="581" srcset="https://www.tempco.it/blog/wp-content/uploads/2022/09/DLA-Piper-crescita-investimenti-data-center-fattori-ESG.jpg 903w, https://www.tempco.it/blog/wp-content/uploads/2022/09/DLA-Piper-crescita-investimenti-data-center-fattori-ESG-300x233.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2022/09/DLA-Piper-crescita-investimenti-data-center-fattori-ESG-768x595.jpg 768w" sizes="(max-width: 750px) 100vw, 750px" /> <img decoding="async" loading="lazy" class="aligncenter wp-image-8703" src="https://www.tempco.it/blog/wp-content/uploads/2022/09/Investimenti-data-center-raffreddamento-a-liquido-ESG.jpg" alt="Investimenti data center raffreddamento a liquido ESG" width="750" height="877" srcset="https://www.tempco.it/blog/wp-content/uploads/2022/09/Investimenti-data-center-raffreddamento-a-liquido-ESG.jpg 1165w, https://www.tempco.it/blog/wp-content/uploads/2022/09/Investimenti-data-center-raffreddamento-a-liquido-ESG-257x300.jpg 257w, https://www.tempco.it/blog/wp-content/uploads/2022/09/Investimenti-data-center-raffreddamento-a-liquido-ESG-768x897.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2022/09/Investimenti-data-center-raffreddamento-a-liquido-ESG-877x1024.jpg 877w" sizes="(max-width: 750px) 100vw, 750px" /></p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/8698/data-center-raddoppiano-gli-investimenti-con-attenzione-ai-temi-esg/" title="Permanent link to Data center, investments double globally with stronger focus on ESG issues">Data center, investments double globally with stronger focus on ESG issues</a>  </li>
<li> <a href="https://www.tempco.it/blog/9619/raffreddamento-a-liquido-e-per-immersione-dei-data-center/" title="Permanent link to Raffreddamento a liquido e scambiatori a immersione dei data center">Raffreddamento a liquido e scambiatori a immersione dei data center</a>  </li>
<li> <a href="https://www.tempco.it/blog/10050/data-center-green-a-ridotto-impatto-ambientale-e-scambiatori-tcoil/" title="Permanent link to Data Center green a ridotto impatto ambientale e scambiatori TCOIL">Data Center green a ridotto impatto ambientale e scambiatori TCOIL</a>  </li>
<li> <a href="https://www.tempco.it/blog/7381/londa-globale-del-liquid-cooling-nei-data-center/" title="Permanent link to L&#8217;onda globale del liquid cooling nei data center">L&#8217;onda globale del liquid cooling nei data center</a>  </li>
<li> <a href="https://www.tempco.it/blog/8646/raffreddamento-a-liquido-in-data-center-e-high-performance-computing/" title="Permanent link to Raffreddamento a liquido in data center e high performance computing">Raffreddamento a liquido in data center e high performance computing</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8698/data-center-raddoppiano-gli-investimenti-con-attenzione-ai-temi-esg/">Data center, raddoppiano gli investimenti con attenzione ai temi ESG</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2022/09/Crescita-investimenti-data-center-temi-ESG-sostenibilità-DLA-Piper-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2022/09/Crescita-investimenti-data-center-temi-ESG-sostenibilità-DLA-Piper.jpg" medium="image">
			<media:title type="html">Crescita investimenti data center temi ESG sostenibilità DLA Piper</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2022/09/Crescita-investimenti-data-center-temi-ESG-sostenibilità-DLA-Piper-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2022/09/DLA-Piper-crescita-investimenti-data-center-fattori-ESG.jpg" medium="image">
			<media:title type="html">DLA Piper crescita investimenti data center fattori ESG</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2022/09/DLA-Piper-crescita-investimenti-data-center-fattori-ESG-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2022/09/Investimenti-data-center-raffreddamento-a-liquido-ESG.jpg" medium="image">
			<media:title type="html">Investimenti data center raffreddamento a liquido ESG</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2022/09/Investimenti-data-center-raffreddamento-a-liquido-ESG-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Raffreddamento a liquido in data center e high performance computing</title>
		<link>https://www.tempco.it/blog/8646/raffreddamento-a-liquido-in-data-center-e-high-performance-computing/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 01 Jul 2022 14:19:45 +0000</pubDate>
				<category><![CDATA[data center]]></category>
		<category><![CDATA[dimple jacket]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[Risparmio energetico]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[Scambiatori ad immersione]]></category>
		<category><![CDATA[Scambiatori di calore]]></category>
		<category><![CDATA[3M]]></category>
		<category><![CDATA[AI]]></category>
		<category><![CDATA[Analytics]]></category>
		<category><![CDATA[cloud computing]]></category>
		<category><![CDATA[condizionamento]]></category>
		<category><![CDATA[core]]></category>
		<category><![CDATA[EDA]]></category>
		<category><![CDATA[edge]]></category>
		<category><![CDATA[elettronica]]></category>
		<category><![CDATA[fluidi dielettrici]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[frequenza di clock]]></category>
		<category><![CDATA[high performance computing]]></category>
		<category><![CDATA[HPC]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[intelligenza artificiale]]></category>
		<category><![CDATA[Kaori]]></category>
		<category><![CDATA[licenze software]]></category>
		<category><![CDATA[potenza di calcolo]]></category>
		<category><![CDATA[processori]]></category>
		<category><![CDATA[raffreddamento a immersione]]></category>
		<category><![CDATA[raffreddamento a liquido]]></category>
		<category><![CDATA[risparmio energetico]]></category>
		<category><![CDATA[Samsung]]></category>
		<category><![CDATA[scambiatori a immersione]]></category>
		<category><![CDATA[scambiatori a piastre]]></category>
		<category><![CDATA[scambiatori di calore]]></category>
		<category><![CDATA[semiconduttori]]></category>
		<category><![CDATA[software]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[sostenibilità]]></category>
		<category><![CDATA[Supermicro]]></category>
		<category><![CDATA[tcoil]]></category>
		<category><![CDATA[TDP]]></category>
		<category><![CDATA[thermal design point]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=8646</guid>

					<description><![CDATA[<p>Test nel raffreddamento a liquido per immersione dell'elettronica nei data center condotti da Supermicro mostrano riduzione del consumo energetico, migliore efficienza di raffreddamento e minori costi di esercizio legati ai software nell'industria dei semiconduttori. </p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8646/raffreddamento-a-liquido-in-data-center-e-high-performance-computing/">Raffreddamento a liquido in data center e high performance computing</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://www.supermicro.com/white_paper/white_paper_Immersion-Cooling.pdf" target="_blank" rel="noopener"><strong>Supermicro</strong></a>, produttore di <strong>server per high performance computing</strong> per applicazioni in <strong>data center, cloud computing, AI, 5G e edge computing</strong>, ha dimostrato in concreto i vantaggi che è possibile ottenere con il <a href="https://www.tempco.it/blog/7381/londa-globale-del-liquid-cooling-nei-data-center/" target="_blank" rel="noopener"><strong>raffreddamento a liquido per immersione</strong></a> in fluidi dielettrici dei dispositivi elettronici. L’azienda ha infatti condotto dei test sul raffreddamento per immersione in collaborazione con <strong>3M</strong>, <strong>Intel</strong>, <strong>Kaori</strong> e <strong>Samsung</strong> misurando non solo la superiore efficienza di raffreddamento ottenibile, con <strong>riduzione del consumo energetico</strong>, ma anche i risparmi nei costi relativi alle <strong>licenze d’uso dei software EDA</strong> (electronic design automation) impiegati nell’<strong>industria dei semiconduttori</strong>.</p>
<p>Il <a href="https://www.tempco.it/blog/7428/come-risparmiare-energia-nel-raffreddamento-dei-data-center/" target="_blank" rel="noopener">raffreddamento a liquido per immersione</a>, di cui abbiamo già parlato in passato mediante utilizzo di <a href="https://www.tempco.it/soluzioni/scambiatori-di-calore/scambiatori-calore-immersione/" target="_blank" rel="noopener"><strong>scambiatori TCOIL</strong></a>, aumenta in prima istanza la <strong>sostenibilità dei data center</strong>, migliorando l’efficienza energetica del sistema di raffreddamento. Infatti, utilizzare un liquido come fluido di raffreddamento invece dell’aria comporta un contatto più stretto delle particelle del liquido con l’oggetto da raffreddare, <strong>aumentando il coefficiente di scambio termico</strong>. Questo consente inoltre di utilizzare <strong>fluidi di raffreddamento a temperature meno spinte</strong>, con notevole risparmio energetico grazie anche alla possibilità di impiegare <a href="https://www.tempco.it/soluzioni/raffreddatori-industriali-elettroradiatori/" target="_blank" rel="noopener"><strong>sistemi in free cooling</strong></a> per il raffreddamento dei fluidi dielettrici e tagliando i costi legati al condizionamento dell’aria.</p>
<p>La soluzione con raffreddamento a liquido nel progetto testato ha però altresì portato a una <strong>riduzione dei costi di esercizio del calcolo ad alte prestazioni</strong> richiesto dai software EDA, dove il costo delle licenze d’uso è legato al <strong>numero di core e alla frequenza di Clock</strong> richiesta (la frequenza di Clock indica il numero di cicli da acceso-spento, ossia tra 0 e 1, che un transistor è in grado di processare in un secondo, misurata in GHz). Grandezze a cui è legato anche il <strong>TDP (thermal design point)</strong>, ovvero il calore massimo che un processore deve smaltire per funzionare in maniera ottimale.</p>
<p><img decoding="async" loading="lazy" class="aligncenter wp-image-8650" src="https://www.tempco.it/blog/wp-content/uploads/2022/07/Tempco-raffreddamento-a-liquido-data-center-HPC.jpg" alt="Tempco raffreddamento a liquido data center HPC" width="781" height="466" srcset="https://www.tempco.it/blog/wp-content/uploads/2022/07/Tempco-raffreddamento-a-liquido-data-center-HPC.jpg 1020w, https://www.tempco.it/blog/wp-content/uploads/2022/07/Tempco-raffreddamento-a-liquido-data-center-HPC-300x179.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2022/07/Tempco-raffreddamento-a-liquido-data-center-HPC-768x459.jpg 768w" sizes="(max-width: 781px) 100vw, 781px" /></p>
<p>Il costo complessivo delle licenze può quindi essere ridotto diminuendo il numero di core utilizzati e aumentando la frequenza di clock, ottenendo lo stesso livello di prestazioni. Ciò comporta però un <strong>incremento nella quantità di calore sviluppato dall’elettronica</strong> da dissipare, che mette le soluzioni di raffreddamento ad aria tradizionali di fronte al loro limite, potendo invece essere gestite senza problemi e con maggior efficienza e consumi inferiori dal raffreddamento a liquido per immersione.</p>
<p>Il sistema prototipale messo a punto da Supermicro in collaborazione con 3M, Intel, Kaori e Samsung sfrutta nello specifico il raffreddamento a immersione diretta di due tipologie di dispositivi di Intel e Samsung, in un serbatoio con sistema a <a href="https://www.tempco.it/soluzioni/scambiatori-di-calore/" target="_blank" rel="noopener"><strong>scambiatori di calore a piastre</strong></a> riempito con il fluido <strong>3M Fluorinert Electronic Liquid FC-40</strong>, che ha mostrato perfetta compatibilità con l’elettronica impiegata.</p>
<p>I test condotti hanno dimostrato una <strong>importante riduzione del consumo energetico</strong> ottenuta con il raffreddamento a liquido per immersione, anche con CPU ad alte prestazioni e in<strong> ambienti a temperatura ambiente</strong>, senza impiego di aria condizionata. Consentendo la riduzione del numero di core nei processori e l&#8217;incremento della clock speed. Prospettando pertanto il raffreddamento a liquido per immersione come una soluzione green e altamente efficiente in grado di ridurre anche i costi di esercizio, adatta alle <strong>crescenti potenze di calcolo richieste ai data center</strong> a sostegno dello sviluppo delle nuove tecnologie, dal campo della progettazione elettronica, all’intelligenza artificiale e all’analisi dei dati.</p>
<div id="attachment_8652" style="width: 500px" class="wp-caption aligncenter"><img aria-describedby="caption-attachment-8652" decoding="async" loading="lazy" class="size-full wp-image-8652" src="https://www.tempco.it/blog/wp-content/uploads/2022/07/Immersion-liquid-cooling-demo-Supermicro-Intel-Samsung-data-center.jpg" alt="Immersion liquid cooling demo Supermicro Intel Samsung data center" width="490" height="662" srcset="https://www.tempco.it/blog/wp-content/uploads/2022/07/Immersion-liquid-cooling-demo-Supermicro-Intel-Samsung-data-center.jpg 490w, https://www.tempco.it/blog/wp-content/uploads/2022/07/Immersion-liquid-cooling-demo-Supermicro-Intel-Samsung-data-center-222x300.jpg 222w" sizes="(max-width: 490px) 100vw, 490px" /><p id="caption-attachment-8652" class="wp-caption-text">Source: Supermicro</p></div>
<p>Per restare informato ogni mese sulle ultime <strong>applicazioni di gestione dell&#8217;energia termica</strong>, iscriviti alla <a href="https://www.tempco.it/newsletter-solid-temperature/" target="_blank" rel="noopener">Newsletter &#8211; Solid Temperature di Tempco</a>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/10050/data-center-green-a-ridotto-impatto-ambientale-e-scambiatori-tcoil/" title="Permanent link to Data Center green a ridotto impatto ambientale e scambiatori TCOIL">Data Center green a ridotto impatto ambientale e scambiatori TCOIL</a>  </li>
<li> <a href="https://www.tempco.it/blog/7381/londa-globale-del-liquid-cooling-nei-data-center/" title="Permanent link to L&#8217;onda globale del liquid cooling nei data center">L&#8217;onda globale del liquid cooling nei data center</a>  </li>
<li> <a href="https://www.tempco.it/blog/7428/come-risparmiare-energia-nel-raffreddamento-dei-data-center/" title="Permanent link to Come risparmiare energia nel raffreddamento dei data center">Come risparmiare energia nel raffreddamento dei data center</a>  </li>
<li> <a href="https://www.tempco.it/blog/8646/raffreddamento-a-liquido-in-data-center-e-high-performance-computing/" title="Permanent link to Immersion liquid cooling in data center and HPC">Immersion liquid cooling in data center and HPC</a>  </li>
<li> <a href="https://www.tempco.it/blog/9619/raffreddamento-a-liquido-e-per-immersione-dei-data-center/" title="Permanent link to Raffreddamento a liquido e scambiatori a immersione dei data center">Raffreddamento a liquido e scambiatori a immersione dei data center</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8646/raffreddamento-a-liquido-in-data-center-e-high-performance-computing/">Raffreddamento a liquido in data center e high performance computing</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2022/07/Tempco-raffreddamento-a-liquido-data-center-HPC-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2022/07/Tempco-raffreddamento-a-liquido-data-center-HPC.jpg" medium="image">
			<media:title type="html">Tempco raffreddamento a liquido data center HPC</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2022/07/Tempco-raffreddamento-a-liquido-data-center-HPC-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2022/07/Immersion-liquid-cooling-demo-Supermicro-Intel-Samsung-data-center.jpg" medium="image">
			<media:title type="html">Immersion liquid cooling demo Supermicro Intel Samsung data center</media:title>
			<media:description type="html">Source: Supermicro</media:description>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2022/07/Immersion-liquid-cooling-demo-Supermicro-Intel-Samsung-data-center-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Infografica dal calore al valore, recupero energetico nell’industria</title>
		<link>https://www.tempco.it/blog/8411/infografica-dal-calore-al-valore-recupero-energetico-nellindustria/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 14 Jan 2022 10:28:04 +0000</pubDate>
				<category><![CDATA[Centraline di recupero energetico]]></category>
		<category><![CDATA[Cogenerazione]]></category>
		<category><![CDATA[dry-cooler]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[Riscaldamento]]></category>
		<category><![CDATA[Risparmio energetico]]></category>
		<category><![CDATA[Scambiatori di calore]]></category>
		<category><![CDATA[alimentare]]></category>
		<category><![CDATA[chimico]]></category>
		<category><![CDATA[cogenerazione]]></category>
		<category><![CDATA[controllo temperatura]]></category>
		<category><![CDATA[dry cooling]]></category>
		<category><![CDATA[efficienza]]></category>
		<category><![CDATA[energia]]></category>
		<category><![CDATA[energia di secondo livello]]></category>
		<category><![CDATA[farmaceutico]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[industria]]></category>
		<category><![CDATA[industria di processo]]></category>
		<category><![CDATA[infografiche]]></category>
		<category><![CDATA[metallurgia]]></category>
		<category><![CDATA[oil and gas]]></category>
		<category><![CDATA[plastica]]></category>
		<category><![CDATA[recupero di calore]]></category>
		<category><![CDATA[recupero energetico]]></category>
		<category><![CDATA[risparmio energetico]]></category>
		<category><![CDATA[scambiatori di calore]]></category>
		<category><![CDATA[solid temperature]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=8411</guid>

					<description><![CDATA[<p>Nuova Infografica Tempco dal Calore al valore, dedicata alle applicazioni per recupero energetico in tutti i settori industriali grazie a impiego di scambiatori di calore per uso efficiente dell'energia.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8411/infografica-dal-calore-al-valore-recupero-energetico-nellindustria/">Infografica dal calore al valore, recupero energetico nell’industria</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>La nuova <a href="https://www.tempco.it/infografiche/dal-calore-al-valore/" target="_blank" rel="noopener"><strong>infografica Tempco</strong></a>, pubblicata sul finire del 2021 e con cui abbiamo piacere di aprire il nuovo anno, è relativa al <strong>mercato del <a href="https://www.tempco.it/soluzioni/recupero-energetico/" target="_blank" rel="noopener">recupero energetico</a></strong>, ambito che consente di <strong>massimizzare il valore insito nel calore</strong>, ovvero l’energia termica quale preziosa risorsa largamente presente nell’industria; e qui Tempco gioca decisamente in casa.</p>
<p>Dopo aver dato uno sguardo con le precedenti Infografiche ai trend nei settori dell’<a href="https://www.tempco.it/infografiche/potenziare-industria/" target="_blank" rel="noopener"><strong>automazione</strong></a> e del <strong><a href="https://www.tempco.it/infografiche/innovare-i-processi/" target="_blank" rel="noopener">potenziamento intelligente dell’industria</a></strong> e al settore delle <a href="https://www.tempco.it/infografiche/progettare-lenergia/" target="_blank" rel="noopener"><strong>energie rinnovabili</strong></a>, le applicazioni di recupero di calore nell’ambito dei processi produttivi sono infatti l’attività distintiva dei progetti che vengono sviluppati in Tempco.</p>
<p>La tecnologia principale considerata nel recupero di calore sono gli <a href="https://www.tempco.it/soluzioni/scambiatori-di-calore/" target="_blank" rel="noopener"><strong>scambiatori di calore</strong></a>, macchinari che sfruttando il principio dello scambio termico tra due fluidi che presentato un gap di temperatura tra loro consentono di riutilizzare l’energia termica, disponibile in grandi quantità in molte tipologie di processi produttivi e che è possibile <strong>reimpiegare come energia di secondo livello</strong> in altri punti del processo. Senza richiedere ulteriore dispendio energetico, contribuendo pertanto in maniera incisiva sul bilancio energetico, implementando logiche di <strong>efficienza e risparmio energetico</strong>, con riduzione delle emissioni e dell’impatto ambientale dei processi produttivi industriali.</p>
<p>Uno sguardo viene dedicato anche a <a href="https://www.tempco.it/soluzioni/raffreddatori-industriali-elettroradiatori/" target="_blank" rel="noopener"><strong>dry cooling</strong></a> e <a href="https://www.tempco.it/soluzioni/cogenerazione/" target="_blank" rel="noopener"><strong>cogenerazione</strong></a>, soluzioni per un uso intelligente e più efficiente dei combustibili, riducendo lo spreco energetico e sfruttando al meglio le risorse disponibili per assolvere compiti di riscaldamento e raffreddamento presenti in ogni tipologia di industria, dal <strong><a href="https://www.tempco.it/blog/7057/raffreddamento-soluzione-di-soda-per-inertizzazioni-oilgas/" target="_blank" rel="noopener">settore oil &amp; gas</a></strong> e <strong><a href="https://www.tempco.it/blog/6285/raffreddamento-delle-lance-di-taglio-nellindustria-metallurgica/" target="_blank" rel="noopener">metallurgico</a></strong>, alla <strong><a href="https://www.tempco.it/blog/8350/regolazione-temperatura-per-laminazione-e-scagliettatura-in-food-e-pharma/" target="_blank" rel="noopener">produzione alimentare</a></strong> e fino alla <strong><a href="https://www.tempco.it/blog/8276/termoregolazione-in-produzione-di-contenitori-in-materiale-plastico-per-farmaceutico/" target="_blank" rel="noopener">lavorazione della plastica</a></strong> e al settore <strong><a href="https://www.tempco.it/blog/8249/termostatazione-reattori-nella-produzione-di-api/" target="_blank" rel="noopener">chimico e farmaceutico</a></strong>. Per tutti questi settori, le parole chiave nella visione di Tempco sono efficienza e recupero energetico.</p>
<p><img decoding="async" loading="lazy" class="aligncenter size-full wp-image-8412" src="https://www.tempco.it/blog/wp-content/uploads/2022/01/infografica-dal-calore-al-valore-recupero-energetico.jpg" alt="infografica-dal-calore-al-valore-recupero energetico" width="1280" height="5758" srcset="https://www.tempco.it/blog/wp-content/uploads/2022/01/infografica-dal-calore-al-valore-recupero-energetico.jpg 1280w, https://www.tempco.it/blog/wp-content/uploads/2022/01/infografica-dal-calore-al-valore-recupero-energetico-67x300.jpg 67w, https://www.tempco.it/blog/wp-content/uploads/2022/01/infografica-dal-calore-al-valore-recupero-energetico-768x3455.jpg 768w" sizes="(max-width: 1280px) 100vw, 1280px" /></p>
<p>Per restare sempre informato ogni mese sulle ultime <strong>applicazioni di gestione dell&#8217;energia termica</strong>, iscriviti qui alla <a href="https://www.tempco.it/newsletter-solid-temperature/" target="_blank" rel="noopener">Newsletter &#8211; Solid Temperature di Tempco</a>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/8298/infografica-tempco-progettare-lenergia-con-le-rinnovabili/" title="Permanent link to Infografica Tempco, progettare l&#8217;energia con le rinnovabili">Infografica Tempco, progettare l&#8217;energia con le rinnovabili</a>  </li>
<li> <a href="https://www.tempco.it/blog/8558/nuova-sezione-referenze-arricchita-nel-sito-tempco/" title="Permanent link to Nuova sezione Referenze arricchita nel sito Tempco">Nuova sezione Referenze arricchita nel sito Tempco</a>  </li>
<li> <a href="https://www.tempco.it/blog/8073/potenziare-lindustria-automazione-e-temperatura-infografica/" title="Permanent link to Potenziare l’industria, automazione e temperatura &#8211; Infografica">Potenziare l’industria, automazione e temperatura &#8211; Infografica</a>  </li>
<li> <a href="https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/" title="Permanent link to Rinnovabili e energy saving con free cooler e torri evaporative">Rinnovabili e energy saving con free cooler e torri evaporative</a>  </li>
<li> <a href="https://www.tempco.it/blog/6580/energia-termica-e-processi-industriali-una-guida/" title="Permanent link to Energia termica e processi industriali, una guida">Energia termica e processi industriali, una guida</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8411/infografica-dal-calore-al-valore-recupero-energetico-nellindustria/">Infografica dal calore al valore, recupero energetico nell’industria</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2022/01/infografica-dal-calore-al-valore-recupero-energetico-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2022/01/infografica-dal-calore-al-valore-recupero-energetico.jpg" medium="image">
			<media:title type="html">infografica-dal-calore-al-valore-recupero energetico</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2022/01/infografica-dal-calore-al-valore-recupero-energetico-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Rinnovabili e energy saving con free cooler e torri evaporative</title>
		<link>https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/</link>
					<comments>https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/#comments</comments>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 03 Dec 2021 12:17:27 +0000</pubDate>
				<category><![CDATA[Chiller]]></category>
		<category><![CDATA[Cooler]]></category>
		<category><![CDATA[dry-cooler]]></category>
		<category><![CDATA[elettroradiatori]]></category>
		<category><![CDATA[Energia Termica]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[Manutenzione]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[Risparmio energetico]]></category>
		<category><![CDATA[Scambiatori di calore]]></category>
		<category><![CDATA[Torri Evaporative]]></category>
		<category><![CDATA[acqua raffreddata]]></category>
		<category><![CDATA[compressori]]></category>
		<category><![CDATA[condizionamento]]></category>
		<category><![CDATA[consumo energetico]]></category>
		<category><![CDATA[controllo elettronico]]></category>
		<category><![CDATA[dry cooler]]></category>
		<category><![CDATA[efficienza]]></category>
		<category><![CDATA[energia termica]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[gruppi frigoriferi]]></category>
		<category><![CDATA[inverter]]></category>
		<category><![CDATA[manutenzione]]></category>
		<category><![CDATA[modulazione potenza]]></category>
		<category><![CDATA[motori ec]]></category>
		<category><![CDATA[raffreddamento]]></category>
		<category><![CDATA[refrigerazione]]></category>
		<category><![CDATA[ridotta manutenzione]]></category>
		<category><![CDATA[rinnovabili]]></category>
		<category><![CDATA[risparmio energetico]]></category>
		<category><![CDATA[ritorno dell'investimento]]></category>
		<category><![CDATA[ROI]]></category>
		<category><![CDATA[scambiatori]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[torri evaporative]]></category>
		<category><![CDATA[usura]]></category>
		<category><![CDATA[velocità variabile]]></category>
		<category><![CDATA[ventilatori]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=8378</guid>

					<description><![CDATA[<p>Motori EC a controllo elettronico che impiegano inverter sono la chiave per implementare il risparmio energetico in applicazioni di raffreddamento con free cooling e torri evaporative. </p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/">Rinnovabili e energy saving con free cooler e torri evaporative</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Parliamo ancora di <a href="https://www.tempco.it/infografiche/progettare-lenergia/" target="_blank" rel="noopener"><strong>energie rinnovabili e risparmio energetico</strong></a> in applicazioni relative alla energia di secondo livello, ossia l’energia termica. Dopo aver parlato dei <a href="https://www.tempco.it/blog/8365/risparmio-energetico-con-inverter-nei-gruppi-frigoriferi/" target="_blank" rel="noopener">gruppi frigoriferi</a>, un altro ambito di importante e interessante declinazione del tema risparmio energetico è quello del <a href="https://www.tempco.it/soluzioni/raffreddatori-industriali-elettroradiatori/" target="_blank" rel="noopener"><strong>free cooling</strong></a> e delle <a href="https://www.tempco.it/soluzioni/torri-evaporative/" target="_blank" rel="noopener"><strong>torri evaporative</strong></a>.</p>
<p>Questi sistemi vengono impiegati quando serve <strong>acqua raffreddata all’interno di un processo industriale</strong> con <strong>temperature al di sopra dei 30-35° C</strong>. Livelli di temperatura per cui è possibile evitare il ricordo a un <a href="https://www.tempco.it/soluzioni/gruppi-frigoriferi/" target="_blank" rel="noopener"><strong>sistema di refrigerazione</strong></a>, eliminando quindi già il consumo energetico legato ai <strong>compressori</strong> e le complicazioni del circuito frigorifero, dell’impiego di freon e così via.</p>
<p>Adottando quindi free cooler, o <a href="https://www.tempco.it/blog/8369/energy-saving-con-dry-cooler-nel-packaging-farmaceutico/" target="_blank" rel="noopener">dry cooler</a>, e torri di raffreddamento, il risparmio energetico può essere implementato utilizzando <a href="https://www.tempco.it/blog/7194/risparmio-energetico-e-motori-ec-nel-freddo/" target="_blank" rel="noopener"><strong>ventilatori con motori EC</strong></a>, ovvero a controllo elettronico, che impiegano <a href="https://www.tempco.it/blog/3717/risparmio-energetico-inverter-motori-ec-a-controllo-elettronico/" target="_blank" rel="noopener">inverter</a>. In questi sistemi avviene infatti che una sonda rileva la temperatura dell’acqua, e in base al set point impostato si va a <strong>regolare la potenza necessaria per dissipare la giusta quantità di energia</strong> per il livello di raffreddamento richiesto.</p>
<p>In passato il costo di motori EC e inverter era ancora molto elevato per giustificarne l&#8217;investimento in queste tecnologie. Si era pertanto soliti fare ricorso a soluzioni alternative di risparmio energetico, con <strong>installazioni multi ventilatore</strong> che veniva azionati a gradini, parzializzando il numero di ventilatori funzionanti limitando il consumo energetico in base alla richiesta effettiva.</p>
<p><iframe loading="lazy" width="750" height="422" src="https://www.youtube.com/embed/6WaJd16H_Ww?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe></p>
<p>Oggi i costi dei motori a controllo elettrico consentono invece <strong>ritorni dell’investimento molto interessanti</strong>. La soluzione è infatti sempre più frequentemente adottata dai clienti, che la abbracciano con soddisfazione in quanto consente non solo di ottenere <strong>effettivi risparmi energetici</strong>, ma anche una <strong>riduzione dei costi di manutenzione</strong>. E’ infatti evidente che l’usura di un ventilatore che funziona a velocità ridotta per sei o nove mesi l&#8217;anno sarà molto minore di quella di un ventilatore che funziona al 100% della sua capacità.</p>
<p>La <strong>soluzione con motori EC e inverter</strong> è quindi molto matura oggi, e può essere ampiamente impiegata in applicazioni industriali ma anche di <strong>condizionamento</strong>, che devono lavorare per 365 giorni l’anno. Chiaramente se un impianto lavora solo in estate, il ritorno dell’investimento sarà probabilmente più lungo. Ma anche qui valutare l&#8217;opportunità può essere molto interessante, in quanto <strong>nelle ore notturne la temperatura scende</strong>, consentendo di rallentare la velocità dei ventilatori in quanto l’<strong>efficienza dello <a href="https://www.tempco.it/soluzioni/scambiatori-di-calore/" target="_blank" rel="noopener">scambiatore</a> è superiore</strong> e ci sarà pertanto minore necessità di aria.</p>
<p>Per restare sempre informato sulle ultime applicazioni, iscriviti qui alla <a href="https://www.tempco.it/newsletter-solid-temperature/" target="_blank" rel="noopener">Newsletter &#8211; Solid Temperature di Tempco</a>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/8176/quando-implementare-il-free-cooling-e-davvero-conveniente/" title="Permanent link to Quando implementare il free cooling è davvero conveniente?">Quando implementare il free cooling è davvero conveniente?</a>  </li>
<li> <a href="https://www.tempco.it/blog/10142/free-cooling-in-cosa-consiste-e-quando-conviene-in-termini-di-roi/" title="Permanent link to Free cooling, in cosa consiste e quando conviene in termini di ROI">Free cooling, in cosa consiste e quando conviene in termini di ROI</a>  </li>
<li> <a href="https://www.tempco.it/blog/7534/raffreddamento-adiabatico-nella-trafilatura-dellacciaio/" title="Permanent link to Raffreddamento adiabatico nella trafilatura dell’acciaio">Raffreddamento adiabatico nella trafilatura dell’acciaio</a>  </li>
<li> <a href="https://www.tempco.it/blog/6329/raffreddamento-adiabatico-in-free-cooling-a-plast-2018%e2%80%a8/" title="Permanent link to Raffreddamento adiabatico in free cooling a Plast 2018 ">Raffreddamento adiabatico in free cooling a Plast 2018 </a>  </li>
<li> <a href="https://www.tempco.it/blog/8233/raffreddamento-preferenza-tra-chiller-torri-e-dry-cooler/" title="Permanent link to Raffreddamento, preferenza tra chiller, torri e dry cooler">Raffreddamento, preferenza tra chiller, torri e dry cooler</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/">Rinnovabili e energy saving con free cooler e torri evaporative</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/feed/</wfw:commentRss>
			<slash:comments>2</slash:comments>
		
		
		
	</item>
		<item>
		<title>Raffreddamento, preferenza tra chiller, torri e dry cooler</title>
		<link>https://www.tempco.it/blog/8233/raffreddamento-preferenza-tra-chiller-torri-e-dry-cooler/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 30 Jul 2021 10:38:43 +0000</pubDate>
				<category><![CDATA[Chiller]]></category>
		<category><![CDATA[dry-cooler]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[Gelo]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[Refrigeratori]]></category>
		<category><![CDATA[Risparmio energetico]]></category>
		<category><![CDATA[Scambiatori di calore]]></category>
		<category><![CDATA[Trattamento delle acque]]></category>
		<category><![CDATA[acqua a circuito chiuso]]></category>
		<category><![CDATA[acqua di raffreddamento]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[compressori]]></category>
		<category><![CDATA[condizioni ambientali]]></category>
		<category><![CDATA[consumo di acqua]]></category>
		<category><![CDATA[dry cooler]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[gelo]]></category>
		<category><![CDATA[glicol]]></category>
		<category><![CDATA[gruppi frigoriferi]]></category>
		<category><![CDATA[risparmio energetico]]></category>
		<category><![CDATA[scambiatori di calore]]></category>
		<category><![CDATA[sistemi di raffreddamento]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[torri di raffreddamento]]></category>
		<category><![CDATA[torri evaporative]]></category>
		<category><![CDATA[trattamento acque]]></category>
		<category><![CDATA[ventilatori EC]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=8233</guid>

					<description><![CDATA[<p>Livello delle temperature cui è richiesta l'acqua di raffreddamento di processo e le condizioni climatiche nella zona di installazione determinano la scelta tra chiller, torri evaporative e free cooler nel raffreddamento.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8233/raffreddamento-preferenza-tra-chiller-torri-e-dry-cooler/">Raffreddamento, preferenza tra chiller, torri e dry cooler</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Un argomento sempre molto richiesto è quale sia il <strong>miglior sistema di raffreddamento</strong> da impiegare per raffreddare acqua da utilizzare per i processi produttivi, quando le opzioni possibili sono <a href="https://www.tempco.it/soluzioni/gruppi-frigoriferi/" target="_blank" rel="noopener"><strong>chiller</strong></a>, <a href="https://www.tempco.it/soluzioni/torri-evaporative/" target="_blank" rel="noopener"><strong>torri evaporative</strong></a> e <a href="https://www.tempco.it/soluzioni/raffreddatori-industriali-elettroradiatori/" target="_blank" rel="noopener"><strong>dry cooler</strong></a>.</p>
<p>La scelta dipende innanzitutto dal <strong>livello di temperatura dell’acqua di raffreddamento</strong> richiesto. Chiaramente, se occorre acqua a 10° C, per esempio, o addirittura a 0° C o sotto zero, l’unica opzione possibile è il gruppo frigorifero, o chiller.</p>
<p>Vi sono poi però molte situazioni intermedie, dove l’acqua di raffreddamento è richiesta a temperature leggermente più elevate, per esempio 20-25 o 30° C, per cui sempre di acqua fredda si parla ma che può essere ottenuta sfruttando altre soluzioni. Ognuna delle quali presenta i suoi vantaggi e svantaggi, naturalmente.</p>
<p>Il <strong><a href="https://www.tempco.it/definizioni/macchine-termiche/refrigeratore-o-chiller/" target="_blank" rel="noopener">gruppo frigorifero</a></strong> è il tipo di macchina termica che meno di tutte risente delle condizioni ambientali, se adeguatamente progettata. Vi sono chiaramente gruppi frigoriferi tropicalizzati che possono operare anche a temperature ambientali elevate, e che grazie ad appositi accorgimenti sono poi in grado di lavorare anche in condizioni invernali. Si parla qui di <strong><a href="https://www.tempco.it/blog/7194/risparmio-energetico-e-motori-ec-nel-freddo/" target="_blank" rel="noopener">ventilatori EC</a></strong>, che provvedono alla variazione della velocità di condensazione.</p>
<p>Quando l’acqua di raffreddamento è richiesta a <strong>25-30° C</strong>, è lì che si apre il dubbio se scegliere chiller, torre evaporativa o dry cooler. Tutto <strong>dipende dalle condizioni ambientali</strong>. Una <a href="https://www.tempco.it/definizioni/macchine-termiche/torre-evaporativa/" target="_blank" rel="noopener"><strong>torre evaporativa</strong></a> alle nostre latitudini, parlo di Italia del nord e centrale, Europa in generale, consente di <strong>ottenere acqua fredda a 29-30 o 31° C</strong> circa. Il <a href="https://www.tempco.it/definizioni/macchine-termiche/free-cooler-dry-cooler/" target="_blank" rel="noopener"><strong>dry cooler</strong></a> a questi livelli di temperatura inizia invece a faticare, in quanto il suo effetto raffreddante dipende strettamente dalla temperatura ambiente. Pertanto, durante la stagione estiva, con temperature che arrivano a 30-35° C, potremo avere acqua a temperature più alte di circa 5° C, quindi <strong>acqua a 35-40° C</strong>. E’ però vero che durante l’inverno, o nella mezza stagione, un dry cooler permette di avere acqua fredda alla temperatura desiderata.</p>
<p><iframe loading="lazy" width="750" height="422" src="https://www.youtube.com/embed/kOixtNPFpYM?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe></p>
<p>Nel confronto tra torre evaporativa e dry cooler, la prima ha il vantaggio di avere <strong>acqua in circuito aperto</strong>, mentre il dry cooler ha un circuito chiuso dell’acqua, con effetti sulle performance. Avere un circuito chiuso però elimina gli effetti della polvere nell’aria e l’evaporazione dell’acqua, <strong>senza quindi consumo di acqua</strong> che porta alla sua concentrazione, rendendo necessario un <a href="https://www.tempco.it/assistenza/trattamento-acque/" target="_blank" rel="noopener">reintegro di acqua trattata</a>.</p>
<p>Di contro, con un circuito chiuso occorre fare <a href="https://www.tempco.it/blog/3856/antigelo-a-protezione-totale/" target="_blank" rel="noopener"><strong>attenzione al congelamento dell’acqua</strong></a> durante l’inverno, onde evitare la rottura dei tubi, e quindi occorre fare ricorso al glicol.</p>
<p>E’ insomma un discorso abbastanza complesso, che caso per caso va valutato per trovare la soluzione migliore. Uno dei trend oggi in corso è <a href="https://www.tempco.it/blog/1926/retrofit-free-cooling/" target="_blank" rel="noopener"><strong>abbinare dei chiller ai dry cooler</strong></a>, o free cooling, che durante l’inverno possono sopperire al funzionamento del gruppo frigorifero, consentendo così di <strong>spegnere i compressori</strong>. Ottenendo significativi risparmi energetici. Lo stesso sistema di free cooling può essere ottenuto usando una <strong>torre evaporativa</strong>, ma in questo caso è consigliabile interporre uno <a href="https://www.tempco.it/soluzioni/scambiatori-di-calore/" target="_blank" rel="noopener"><strong>scambiatore di calore</strong></a>, in quanto la torre a circuito aperto va incontro a contaminazione dell’acqua, che andrebbe trattata per non fornire acqua contaminata al processo produttivo.</p>
<p>Per restare sempre informato sulle ultime applicazioni, iscriviti qui alla <a href="https://www.tempco.it/newsletter-solid-temperature/" target="_blank" rel="noopener">Newsletter &#8211; Solid Temperature di Tempco</a>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/8176/quando-implementare-il-free-cooling-e-davvero-conveniente/" title="Permanent link to Quando implementare il free cooling è davvero conveniente?">Quando implementare il free cooling è davvero conveniente?</a>  </li>
<li> <a href="https://www.tempco.it/blog/10142/free-cooling-in-cosa-consiste-e-quando-conviene-in-termini-di-roi/" title="Permanent link to Free cooling, in cosa consiste e quando conviene in termini di ROI">Free cooling, in cosa consiste e quando conviene in termini di ROI</a>  </li>
<li> <a href="https://www.tempco.it/blog/7534/raffreddamento-adiabatico-nella-trafilatura-dellacciaio/" title="Permanent link to Raffreddamento adiabatico nella trafilatura dell’acciaio">Raffreddamento adiabatico nella trafilatura dell’acciaio</a>  </li>
<li> <a href="https://www.tempco.it/blog/8822/macchine-termiche-la-regola-delle-quattro-dita/" title="Permanent link to Macchine termiche, la regola delle quattro dita">Macchine termiche, la regola delle quattro dita</a>  </li>
<li> <a href="https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/" title="Permanent link to Rinnovabili e energy saving con free cooler e torri evaporative">Rinnovabili e energy saving con free cooler e torri evaporative</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8233/raffreddamento-preferenza-tra-chiller-torri-e-dry-cooler/">Raffreddamento, preferenza tra chiller, torri e dry cooler</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Quando implementare il free cooling è davvero conveniente?</title>
		<link>https://www.tempco.it/blog/8176/quando-implementare-il-free-cooling-e-davvero-conveniente/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 18 Jun 2021 12:55:24 +0000</pubDate>
				<category><![CDATA[Chiller]]></category>
		<category><![CDATA[Cooler]]></category>
		<category><![CDATA[dissipatori]]></category>
		<category><![CDATA[dry-cooler]]></category>
		<category><![CDATA[Free cooler]]></category>
		<category><![CDATA[Free cooling]]></category>
		<category><![CDATA[pompaggio dell'acqua]]></category>
		<category><![CDATA[radiatori]]></category>
		<category><![CDATA[Raffreddamento]]></category>
		<category><![CDATA[Refrigeratori]]></category>
		<category><![CDATA[Risparmio energetico]]></category>
		<category><![CDATA[acqua refrigerata]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[compressori]]></category>
		<category><![CDATA[consumo energetico]]></category>
		<category><![CDATA[dry cooling]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[gruppi frigoriferi]]></category>
		<category><![CDATA[pompaggio acqua]]></category>
		<category><![CDATA[raffreddamento]]></category>
		<category><![CDATA[risparmio energetico]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[ventilatori]]></category>
		<category><![CDATA[ventilazione]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=8176</guid>

					<description><![CDATA[<p>La convenienza di implementare un sistema di free cooling combinato con gruppi frigoriferi nel raffreddamento di processi industriali dipende dalle temperature richieste dal processo e dalle temperature stagionali locali.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8176/quando-implementare-il-free-cooling-e-davvero-conveniente/">Quando implementare il free cooling è davvero conveniente?</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>In ambito di <strong>risparmio energetico</strong>, un trend in atto è quello di implementare sistemi di <a href="https://www.tempco.it/soluzioni/raffreddatori-industriali-elettroradiatori/" target="_blank" rel="noopener"><strong>free cooling</strong></a> combinati a <a href="https://www.tempco.it/soluzioni/gruppi-frigoriferi/" target="_blank" rel="noopener"><strong>gruppi frigoriferi</strong></a>, o <a href="https://www.tempco.it/definizioni/macchine-termiche/refrigeratore-o-chiller/" target="_blank" rel="noopener"><strong>chiller</strong></a>, impiegati nel raffreddamento di processi industriali.</p>
<p>Quando il raffreddamento in un certo processo produttivo richiede ad esempio <strong>acqua alla temperatura di 15° C</strong>, è infatti necessario ricorrere a chiller che consentono di ottenere acqua a quelle temperature per tutto l’anno. Durante l’inverno è però possibile <strong>sfruttare sistemi a scambio diretto</strong> grazie alle basse temperature ambientali. Si tratta di sistemi <a href="https://www.tempco.it/blog/7100/dry-cooling-autodrenante-raffreddamento-economico-in-ogni-stagione/" target="_blank" rel="noopener">dry cooling o free cooling</a>, che consistono in batterie di scambio o grandi <strong>radiatori ventilati</strong> che permettono di raffreddare l’acqua.</p>
<p>La convenienza del sistema dipende da due fattori, in primo luogo la <strong>latitudine del sito di installazione</strong> dell’impianto. In secondo, il livello di <strong>temperature dell’acqua di raffreddamento richiesto</strong> dal processo industriale implicato.</p>
<p><iframe loading="lazy" width="750" height="422" src="https://www.youtube.com/embed/kHOFRQhQZk8?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe></p>
<p>Ipotizzando di avere un processo che necessita acqua di raffreddamento a 15° C, durante l’estate sarà indispensabile avere un chiller. In inverno, invece, o comunque <strong>quando la temperatura esterna scende al di sotto dei 10° C</strong>, è possibile avere acqua a 15° C utilizzando un normale dry cooler. Ottenendo un <strong>notevole risparmio energetico</strong>: infatti si avrà comunque l’energia consumata per il <strong>pompaggio dell’acqua</strong> e per il <strong>circuito di ventilazione</strong>, ma si potranno <strong>spegnere completamente i compressori</strong> del gruppo frigorifero. Che per un impianto ad esempio da 100 kW possono comportare un consumo energetico di circa 30 kW l’ora. Il risparmio energetico ottenibile spegnendo i compressori sarà quindi tanto maggiore quanto più importanti sono le potenze termiche richieste.</p>
<p>Occorre pertanto valutare sia le temperature richieste dal processo sia le temperature medie stagionali nel sito di installazione, onde valutare accuratamente e caso per caso il <strong>ritorno dell’investimento dell’implementazione di un sistema di free cooling</strong>.</p>
<p>Per restare sempre informato sulle ultime applicazioni, iscriviti qui alla <a href="https://www.tempco.it/newsletter-solid-temperature/" target="_blank" rel="noopener">Newsletter &#8211; Solid Temperature di Tempco</a>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/10142/free-cooling-in-cosa-consiste-e-quando-conviene-in-termini-di-roi/" title="Permanent link to Free cooling, in cosa consiste e quando conviene in termini di ROI">Free cooling, in cosa consiste e quando conviene in termini di ROI</a>  </li>
<li> <a href="https://www.tempco.it/blog/8233/raffreddamento-preferenza-tra-chiller-torri-e-dry-cooler/" title="Permanent link to Raffreddamento, preferenza tra chiller, torri e dry cooler">Raffreddamento, preferenza tra chiller, torri e dry cooler</a>  </li>
<li> <a href="https://www.tempco.it/blog/8378/rinnovabili-e-energy-saving-con-free-cooler-e-torri-evaporative/" title="Permanent link to Rinnovabili e energy saving con free cooler e torri evaporative">Rinnovabili e energy saving con free cooler e torri evaporative</a>  </li>
<li> <a href="https://www.tempco.it/blog/6329/raffreddamento-adiabatico-in-free-cooling-a-plast-2018%e2%80%a8/" title="Permanent link to Raffreddamento adiabatico in free cooling a Plast 2018 ">Raffreddamento adiabatico in free cooling a Plast 2018 </a>  </li>
<li> <a href="https://www.tempco.it/blog/8822/macchine-termiche-la-regola-delle-quattro-dita/" title="Permanent link to Macchine termiche, la regola delle quattro dita">Macchine termiche, la regola delle quattro dita</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/8176/quando-implementare-il-free-cooling-e-davvero-conveniente/">Quando implementare il free cooling è davvero conveniente?</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
	</channel>
</rss>
