<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:media="http://search.yahoo.com/mrss/"
	>

<channel>
	<title>Heating Archivi - Tempco Blog</title>
	<atom:link href="https://www.tempco.it/blog/en/category/heating/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.tempco.it/blog/en/category/heating/</link>
	<description>Solutions for the thermal energy</description>
	<lastBuildDate>Fri, 31 Jul 2026 09:11:58 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.8</generator>
	<item>
		<title>Design upon ‘batch’: thermal duty changes the rules in pharma</title>
		<link>https://www.tempco.it/blog/en/11457/design-upon-batch-thermal-duty-changes-the-rules-in-pharma/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 31 Jul 2026 09:11:58 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[batch]]></category>
		<category><![CDATA[batch production]]></category>
		<category><![CDATA[chemical industry]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[engineering]]></category>
		<category><![CDATA[expansion vessel]]></category>
		<category><![CDATA[heat transfer fluids]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[pharma]]></category>
		<category><![CDATA[pharmaceutical]]></category>
		<category><![CDATA[production recipes]]></category>
		<category><![CDATA[ramps]]></category>
		<category><![CDATA[safety]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[space saving]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[temperature control]]></category>
		<category><![CDATA[thermal duty]]></category>
		<category><![CDATA[thermal ramps]]></category>
		<category><![CDATA[thermal shocks]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11457</guid>

					<description><![CDATA[<p>Design and sizing of temperature control units (TCUs) based on batch production - typical of the pharmaceutical and chemical industries- which requires a departure from standard sizing rules, such as those used for expansion vessels.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11457/design-upon-batch-thermal-duty-changes-the-rules-in-pharma/">Design upon ‘batch’: thermal duty changes the rules in pharma</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://www.tempco.it/blog/en/11431/one-fluid-many-temperatures-how-to-regulate-the-temperature-of-a-glass-lined-reactor/" target="_blank" rel="noopener"><strong>Thermoregulation</strong></a> in the <a href="https://www.tempco.it/blog/en/11296/modulating-power-temperature-control-unit-for-a-pharma-reactor/" target="_blank" rel="noopener"><strong>pharma</strong></a> and <a href="https://www.tempco.it/blog/en/6839/atex-thermoregulation-in-chemical-production/" target="_blank" rel="noopener"><strong>chemical industries</strong></a> presents unique challenges, particularly regarding the standard rules used to size heating and cooling systems. Operations in the pharmaceutical and fine chemical sectors are <strong>typically batch-based</strong>, involving <strong>short periods of intense production</strong> followed by cleaning, recipe changes, and line restarts.</p>
<p><img decoding="async" class="aligncenter  wp-image-11458" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-pharma-chimico-progettazione-per-campagne-batch-1.jpg" alt="Illustrative image related to the engineering of TCUs for the pharma and chemical sectors, where system sizing must be based on the batch production methods characteristic of these industries." width="629" height="419" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-pharma-chimico-progettazione-per-campagne-batch-1.jpg 1304w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-pharma-chimico-progettazione-per-campagne-batch-1-300x200.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-pharma-chimico-progettazione-per-campagne-batch-1-1024x682.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-pharma-chimico-progettazione-per-campagne-batch-1-768x512.jpg 768w" sizes="(max-width: 629px) 100vw, 629px" /><br />
For a <strong>TCU</strong> (<a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener"><strong>Temperature Control Unit</strong></a>), this entails <strong>rapid temperature ramps</strong>,<strong> continuous thermal shocks</strong>, and fluctuations in heat transfer fluid volume. In such cases, sizing based on standard rules is no more effective. A practical example is the <strong>design of the <a href="https://www.tempco.it/blog/en/9354/where-to-install-the-expansion-vessel-on-hydraulic-plants/" target="_blank" rel="noopener">expansion vessel</a></strong>: in these chemical and pharmaceutical applications, the fluid undergoes massive expansion as temperatures shift from -15°C to over 140°C.</p>
<p>For instance, a theoretical calculation based on standard parameters suggested a 1.800-liter tank for a particular customer application; however, by <strong>analyzing the fluid&#8217;s actual transient dynamics</strong>, we optimized the size it to just 1.000 liters.</p>
<p>The result was impressive: a <strong>44% space saving on the skid</strong> while maintaining maximum safety, even during the most extreme thermal peaks.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/10896/precision-and-hygiene-in-stainless-steel-for-pharma-and-food-thermoregulation/" title="Permanent link to Precision and hygiene in stainless steel for pharma and food thermoregulation">Precision and hygiene in stainless steel for pharma and food thermoregulation</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11431/one-fluid-many-temperatures-how-to-regulate-the-temperature-of-a-glass-lined-reactor/" title="Permanent link to One fluid, many temperatures: how to regulate the temperature of a glass-lined reactor">One fluid, many temperatures: how to regulate the temperature of a glass-lined reactor</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" title="Permanent link to Temperature control units for reactors at -30° C in the pharma industry">Temperature control units for reactors at -30° C in the pharma industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10426/treg-thermoregulation-units-in-automotive-and-ev-test-benches/" title="Permanent link to TREG thermoregulation units in automotive and EV test benches">TREG thermoregulation units in automotive and EV test benches</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10338/thermoregulation-units-what-determines-the-choice-of-carrier-fluids-in-tcu/" title="Permanent link to Thermoregulation units, what determines the choice of carrier fluids in TCU">Thermoregulation units, what determines the choice of carrier fluids in TCU</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11457/design-upon-batch-thermal-duty-changes-the-rules-in-pharma/">Design upon ‘batch’: thermal duty changes the rules in pharma</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-pharma-chimico-progettazione-per-campagne-batch-1-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-pharma-chimico-progettazione-per-campagne-batch-1.jpg" medium="image">
			<media:title type="html">Tempco termoregolazione pharma chimico progettazione per campagne batch</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-pharma-chimico-progettazione-per-campagne-batch-1-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>One fluid, many temperatures: how to regulate the temperature of a glass-lined reactor</title>
		<link>https://www.tempco.it/blog/en/11431/one-fluid-many-temperatures-how-to-regulate-the-temperature-of-a-glass-lined-reactor/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 17 Jul 2026 09:36:16 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[glass-lined reactors]]></category>
		<category><![CDATA[glycol]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[pharma]]></category>
		<category><![CDATA[pharmaceutical]]></category>
		<category><![CDATA[reactors]]></category>
		<category><![CDATA[single-fluid temperature control]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[steam]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[thermal shock]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<category><![CDATA[utility fluids]]></category>
		<category><![CDATA[water]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11431</guid>

					<description><![CDATA[<p>Single-fluid temperature control for a glass-lined pharmaceutical reactor: a single fluid circulates through the reactor jacket, with its temperature regulated externally by three utility fluids—glycol, water, and steam—to prevent thermal shock and cracking of the glass lining.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11431/one-fluid-many-temperatures-how-to-regulate-the-temperature-of-a-glass-lined-reactor/">One fluid, many temperatures: how to regulate the temperature of a glass-lined reactor</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://www.tempco.it/blog/en/8618/steam-heating-in-monofluid-thermoregulation-video-and-interactive-3d-models/" target="_blank" rel="noopener"><strong>Single-fluid thermoregulation</strong></a> is widely used in the <a href="https://www.tempco.it/blog/en/11051/precise-thermal-control-in-pharmaceutical-research/" target="_blank" rel="noopener">pharmaceutical industry</a>; Tempco recently supplied a <a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener"><strong>TCU (Temperature Control Unit)</strong></a> to regulate the temperature of a <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" target="_blank" rel="noopener"><strong>glass-lined pharmaceutical reactor</strong></a> with a capacity of approximately 8,000 liters.</p>
<p>A natural question arises: why not feed <strong>utility fluids (glycol, water, steam)</strong> directly into the reactor jacket? While this might seem like the simplest approach, for glass-lined reactors, it would be a perfect recipe for disaster. <strong>Glass linings are highly sensitive to sudden temperature fluctuations</strong>; injecting steam at 8 bar immediately after glycol at -15°C risks causing catastrophic cracking.</p>
<p>The solution lies in the adoption of the <strong>mono-fluid temperature control concept across an extended range</strong>: a single heat-transfer fluid circulates continuously within the jacket&#8217;s closed loop, while three utility fluids (<strong>glycol at -15° C</strong>, <strong>industrial water at 25° C</strong>, and <strong>steam at 8 bar</strong>) condition its temperature outside the reactor itself.</p>
<p><img decoding="async" loading="lazy" class="aligncenter wp-image-11434" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-monofluido-reattore-pharma-evitare-shock-termici-1.jpg" alt="Image illustrating the single-fluid temperature control of a glass-lined pharmaceutical reactor, where a single fluid circulates within the jacket; the fluid's temperature is regulated externally to the reactor by three utility fluids—glycol, water, and steam—to prevent thermal shock and cracking of the glass lining." width="681" height="380" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-monofluido-reattore-pharma-evitare-shock-termici-1.jpg 1376w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-monofluido-reattore-pharma-evitare-shock-termici-1-300x167.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-monofluido-reattore-pharma-evitare-shock-termici-1-1024x572.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-monofluido-reattore-pharma-evitare-shock-termici-1-768x429.jpg 768w" sizes="(max-width: 681px) 100vw, 681px" /></p>
<p>The resulting advantage is clear: the <strong>intermediate fluid acts as a thermal buffer</strong>, ensuring excellent temperature uniformity across the vessel wall, thermoregulation precision within a tenth of a degree, and the elimination of thermal shock to the glass lining.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" title="Permanent link to Temperature control units for reactors at -30° C in the pharma industry">Temperature control units for reactors at -30° C in the pharma industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11457/design-upon-batch-thermal-duty-changes-the-rules-in-pharma/" title="Permanent link to Design upon ‘batch’: thermal duty changes the rules in pharma">Design upon ‘batch’: thermal duty changes the rules in pharma</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8542/high-precision-thermoregulation-in-mono-fluid-mode/" title="Permanent link to High precision thermoregulation in mono fluid mode">High precision thermoregulation in mono fluid mode</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10338/thermoregulation-units-what-determines-the-choice-of-carrier-fluids-in-tcu/" title="Permanent link to Thermoregulation units, what determines the choice of carrier fluids in TCU">Thermoregulation units, what determines the choice of carrier fluids in TCU</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11296/modulating-power-temperature-control-unit-for-a-pharma-reactor/" title="Permanent link to Modulating power temperature control unit for a pharma reactor">Modulating power temperature control unit for a pharma reactor</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11431/one-fluid-many-temperatures-how-to-regulate-the-temperature-of-a-glass-lined-reactor/">One fluid, many temperatures: how to regulate the temperature of a glass-lined reactor</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-monofluido-reattore-pharma-evitare-shock-termici-1-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-monofluido-reattore-pharma-evitare-shock-termici-1.jpg" medium="image">
			<media:title type="html">Tempco termoregolazione monofluido reattore pharma evitare shock termici</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-termoregolazione-monofluido-reattore-pharma-evitare-shock-termici-1-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Five key data for heat exchangers sizing</title>
		<link>https://www.tempco.it/blog/en/11414/five-key-data-for-heat-exchangers-sizing/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 10 Jul 2026 09:34:55 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[Manualistica]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[engineering]]></category>
		<category><![CDATA[exchangers]]></category>
		<category><![CDATA[flow rate]]></category>
		<category><![CDATA[fouling]]></category>
		<category><![CDATA[gas]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[pressure]]></category>
		<category><![CDATA[pressure drop]]></category>
		<category><![CDATA[sizing]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[Tempco]]></category>
		<category><![CDATA[temperature]]></category>
		<category><![CDATA[thermal calculation]]></category>
		<category><![CDATA[tutorial]]></category>
		<category><![CDATA[viscosity]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11414</guid>

					<description><![CDATA[<p>Five thermal calculation parameters required to size heat exchangers, including fluid inlet and outlet temperatures, flow rates, and fluid pressure - the latter being critical for gases.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11414/five-key-data-for-heat-exchangers-sizing/">Five key data for heat exchangers sizing</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Tempco</strong> has created a clear, concise tutorial to simplify the selection of <strong>data needed to size <a href="https://en.tempco.it/solutions-en/heat-exchangers/" target="_blank" rel="noopener">heat exchangers</a></strong>. When performing <a href="https://www.tempco.it/blog/en/8801/five-fingers-rule-and-heat-exchangers/" target="_blank" rel="noopener">thermal calculations for heat exchangers</a>, it is not necessary to provide every data point listed in the document for completeness &#8211; only a specific subset is required.</p>
<p>In fact, as indicated in the documentation, just <strong>five of the listed data are necessary</strong> and sufficient: the &#8216;must-have&#8217; data &#8211; essential for initiating the sizing process- are those required for the <strong>thermal calculation</strong>:</p>
<ul>
<li>Primary fluid inlet and outlet temperatures</li>
<li>Primary fluid flow rate</li>
<li>Secondary fluid inlet and outlet temperatures</li>
<li>Secondary fluid flow rate</li>
<li>Fluid pressure (crucial in the case of gases)</li>
</ul>
<p><strong>Capacity</strong> is another important factor for the thermal sizing of the exchanger; however, if the other five data are available, capacity can be calculated from them.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11415" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN.jpg" alt="Image illustrating the essential and useful data for sizing heat exchangers." width="700" height="384" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN.jpg 1862w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-300x164.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-1024x561.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-768x421.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-1536x841.jpg 1536w" sizes="(max-width: 700px) 100vw, 700px" /></p>
<p>The other data listed under the heading &#8220;DATA FOR HEAT EXCHANGERS DESIGN AND CONSTRUCTION&#8221; are <strong>useful for a more precise and comprehensive design</strong> but are not essential for an initial thermal calculation:</p>
<ul>
<li>Fluid types</li>
<li>Max. operating temperature</li>
<li>Max. operating pressure</li>
<li>Oversizing % (margin)</li>
<li>Allowable pressure drops (primary and secondary)</li>
<li>Fluid viscosity</li>
<li>Fluid specific weight</li>
<li>Heat transfer coefficient</li>
<li>Fouling factor</li>
</ul>
<p>In summary, to begin the sizing process, it is <strong>essential to provide at least five of the listed thermal parameters</strong> &#8211; including <strong>pressure if a gas is involved</strong>. The remaining data help refine the unit&#8217;s design specifications but are not required at the initial stage. It is important to note that for <strong>special fluids</strong>, you must <a href="https://en.tempco.it/contacts/" target="_blank" rel="noopener"><strong>contact Tempco directly</strong></a>, as specified in the document.</p>
<p>FIVE FINGERS RULE<br />
<iframe loading="lazy" title="Conoscete la regola delle 5 dita?" width="750" height="422" src="https://www.youtube.com/embed/Tw3VHtWNgp4?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>&nbsp;</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11417" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1019" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-1056x1536.jpg 1056w" sizes="(max-width: 700px) 100vw, 700px" /> <img decoding="async" loading="lazy" class="aligncenter  wp-image-11419" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1018" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-1056x1536.jpg 1056w" sizes="(max-width: 700px) 100vw, 700px" /> <img decoding="async" loading="lazy" class="aligncenter  wp-image-11421" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1018" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-1056x1536.jpg 1056w" sizes="(max-width: 700px) 100vw, 700px" /> <img decoding="async" loading="lazy" class="aligncenter  wp-image-11423" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1018" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-1056x1536.jpg 1056w" sizes="(max-width: 700px) 100vw, 700px" /></p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8801/five-fingers-rule-and-heat-exchangers/" title="Permanent link to Five fingers rule and heat exchangers">Five fingers rule and heat exchangers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/" title="Permanent link to Tempco&#8217;s spare parts ordering guide for plate heat exchangers">Tempco&#8217;s spare parts ordering guide for plate heat exchangers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8550/preventive-maintenance-for-heat-exchangers-efficiency/" title="Permanent link to Preventive maintenance for heat exchangers efficiency">Preventive maintenance for heat exchangers efficiency</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8569/fluids-flow-in-heat-exchangers-counter-flow-vs-parallel-flow/" title="Permanent link to Fluid’s flow in heat exchangers, counter-flow vs. parallel-flow">Fluid’s flow in heat exchangers, counter-flow vs. parallel-flow</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8999/sustainability-and-heat-exchangers-a-whole-month-dedicated-to-renewables/" title="Permanent link to Sustainability and heat exchangers, a whole month dedicated to Renewables">Sustainability and heat exchangers, a whole month dedicated to Renewables</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11414/five-key-data-for-heat-exchangers-sizing/">Five key data for heat exchangers sizing</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN.jpg" medium="image">
			<media:title type="html">Tempco cinque dati necessari dimensionamento scambiatori EN</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1.jpg" medium="image">
			<media:title type="html">Tempco tutorial dati dimensionamento scambiatori 1</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1.jpg" medium="image">
			<media:title type="html">Tempco tutorial dati dimensionamento scambiatori 2</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1.jpg" medium="image">
			<media:title type="html">Tempco tutorial dati dimensionamento scambiatori 3</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1.jpg" medium="image">
			<media:title type="html">Tempco tutorial dati dimensionamento scambiatori 4</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>UL-certified temperature control unit for carbon fiber impregnation</title>
		<link>https://www.tempco.it/blog/en/11344/ul-certified-temperature-control-unit-for-carbon-fiber-impregnation/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 29 May 2026 10:06:19 +0000</pubDate>
				<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[Canada]]></category>
		<category><![CDATA[carbon fiber]]></category>
		<category><![CDATA[cavitation]]></category>
		<category><![CDATA[certifications]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[diathermic oil]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[impregnation]]></category>
		<category><![CDATA[magnetic drive pumps]]></category>
		<category><![CDATA[mechanical seals]]></category>
		<category><![CDATA[North American market]]></category>
		<category><![CDATA[regulations]]></category>
		<category><![CDATA[safety]]></category>
		<category><![CDATA[shell and tube]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[temperature control]]></category>
		<category><![CDATA[temperature control units]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<category><![CDATA[UL]]></category>
		<category><![CDATA[United States]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11344</guid>

					<description><![CDATA[<p>Special TCU diathermic oil temperature control unit, with maximum design temperature of 300° C and magnetic drive pump, with UL construction for carbon fiber impregnation.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11344/ul-certified-temperature-control-unit-for-carbon-fiber-impregnation/">UL-certified temperature control unit for carbon fiber impregnation</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>For an interesting customer application, involving the <strong>impregnation of <a href="https://www.tempco.it/blog/en/10387/strength-and-resistance-with-thermoregulation-in-carbon-fiber-production/">carbon fibers</a></strong> and other specialty fibers, Tempco has designed and delivered a special <strong><a href="https://www.tempco.it/blog/en/6172/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil/" target="_blank" rel="noopener">diathermic oil</a> <a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener">temperature control unit</a></strong> with a <strong>maximum design temperature of 300° C</strong>. The unit&#8217;s operating temperature is 250°C, with a heating power of 24 kW (12+12 UL).</p>
<p>An important feature of this TCU is its construction in <strong>compliance with <a href="https://www.tempco.it/blog/en/8197/mono-fluid-thermoregulation-in-pharmaceutical-industry/" target="_blank" rel="noopener">UL regulations</a></strong>, which establish safety standards for electrical and electronic equipment for use in the <strong>North American market</strong>. UL certification therefore allows our <strong>Tempco TREG units</strong> to be exported and installed for applications in the United States and Canada.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11345" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-UL-impregnazione-fibra-di-carbonio-1.jpg" alt="Image showing a Tempco diathermic oil temperature control unit for carbon fiber impregnation with UL construction." width="500" height="667" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-UL-impregnazione-fibra-di-carbonio-1.jpg 1276w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-UL-impregnazione-fibra-di-carbonio-1-225x300.jpg 225w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-UL-impregnazione-fibra-di-carbonio-1-768x1024.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-UL-impregnazione-fibra-di-carbonio-1-1152x1536.jpg 1152w" sizes="(max-width: 500px) 100vw, 500px" /></p>
<p>This particular thermoregulation unit has a cooling section using a <a href="https://en.tempco.it/solutions-en/heat-exchangers/shell-and-tube-heat-exchangers/" target="_blank" rel="noopener"><strong>shell and tube exchanger</strong></a> with stainless steel core. The TCU&#8217;s power supply is 575V-3Ph-60Hz-3Ph+T. The oil circuit is finally served by a UL 100 liter, 30 meter, 2.8 kW <a href="https://www.tempco.it/blog/en/8273/magnetic-drive-pumps-to-ensure-safety-in-thermoregulation/" target="_blank" rel="noopener"><strong>magnetic drive pump</strong></a>. The choice to use a magnetic drive pump, as an alternative to traditional mechanical seal pumps, is based on safety considerations.</p>
<p>Magnetic drive pumps eliminate any type of mechanical coupling, instead using a magnetic coupling between the motor shaft and the pressurized oil in the pump impeller. The <strong>exclusion of mechanical seals in the pumping circuit</strong> therefore eliminates any risk of possible leakage of diathermic oil at extremely high-temperature, ensuring overall safety of the equipment and eliminating the risk of <a href="https://www.tempco.it/blog/en/7819/how-to-prevent-cavitation-in-centrifugal-pumps/" target="_blank" rel="noopener">pump cavitation</a> due to air infiltration.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11347" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-olio-diatermico-UL-impregnazione-fibra-di-carbonio-1.jpg" alt="Image showing a Tempco TCU high-temperature diathermic oil temperature control unit for carbon fiber impregnation with UL construction." width="500" height="667" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-olio-diatermico-UL-impregnazione-fibra-di-carbonio-1.jpg 1276w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-olio-diatermico-UL-impregnazione-fibra-di-carbonio-1-225x300.jpg 225w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-olio-diatermico-UL-impregnazione-fibra-di-carbonio-1-768x1024.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-olio-diatermico-UL-impregnazione-fibra-di-carbonio-1-1152x1536.jpg 1152w" sizes="(max-width: 500px) 100vw, 500px" /></p>
<p>&nbsp;</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8273/magnetic-drive-pumps-to-ensure-safety-in-thermoregulation/" title="Permanent link to Magnetic drive pumps to ensure safety in thermoregulation">Magnetic drive pumps to ensure safety in thermoregulation</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" title="Permanent link to Temperature control units for reactors at -30° C in the pharma industry">Temperature control units for reactors at -30° C in the pharma industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11271/thermoregulation-for-custom-carbon-fiber-components/" title="Permanent link to Thermoregulation for custom carbon fiber components">Thermoregulation for custom carbon fiber components</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10387/strength-and-resistance-with-thermoregulation-in-carbon-fiber-production/" title="Permanent link to Strength and resistance with thermoregulation in carbon fiber production">Strength and resistance with thermoregulation in carbon fiber production</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10338/thermoregulation-units-what-determines-the-choice-of-carrier-fluids-in-tcu/" title="Permanent link to Thermoregulation units, what determines the choice of carrier fluids in TCU">Thermoregulation units, what determines the choice of carrier fluids in TCU</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11344/ul-certified-temperature-control-unit-for-carbon-fiber-impregnation/">UL-certified temperature control unit for carbon fiber impregnation</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-UL-impregnazione-fibra-di-carbonio-1-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-UL-impregnazione-fibra-di-carbonio-1.jpg" medium="image">
			<media:title type="html">Tempco centralina termoregolazione UL impregnazione fibra di carbonio</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-UL-impregnazione-fibra-di-carbonio-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-olio-diatermico-UL-impregnazione-fibra-di-carbonio-1.jpg" medium="image">
			<media:title type="html">Tempco centralina termoregolazione olio diatermico UL impregnazione fibra di carbonio</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-olio-diatermico-UL-impregnazione-fibra-di-carbonio-1-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Tempco&#8217;s spare parts ordering guide for plate heat exchangers</title>
		<link>https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 22 May 2026 09:50:22 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[Maintenance]]></category>
		<category><![CDATA[Manualistica]]></category>
		<category><![CDATA[Manutenzione]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[Service]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[assistance]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[exchangers]]></category>
		<category><![CDATA[gaskets]]></category>
		<category><![CDATA[guarnizioni]]></category>
		<category><![CDATA[heat transfer]]></category>
		<category><![CDATA[heat transfer plates]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[maintenance]]></category>
		<category><![CDATA[manuals]]></category>
		<category><![CDATA[manutenzione]]></category>
		<category><![CDATA[original spare parts]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[reconditioning]]></category>
		<category><![CDATA[revamping]]></category>
		<category><![CDATA[safety]]></category>
		<category><![CDATA[service]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[spare parts]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11313</guid>

					<description><![CDATA[<p>Tempco's manual for the correct selection of spare parts for heat transfer plates and gaskets in plate heat exchangers, essential in order to ensure maximum efficiency, operational safety, and longevity.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/">Tempco&#8217;s spare parts ordering guide for plate heat exchangers</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>To ensure high thermal performance and long-lasting durability, choosing<strong> original spare parts</strong> for <a href="https://en.tempco.it/solutions-en/heat-exchangers/" target="_blank" rel="noopener"><strong>plate heat exchangers</strong></a> is essential. To support users in the correct selection of original spare parts for <strong>plates and gaskets</strong>, Tempco has developed a dedicated Manual that allows customers to always ensure the highest levels of efficiency and operational safety for their thermal management plants.</p>
<p>The <a href="https://en.tempco.it/assistance/service-exchangers/" target="_blank" rel="noopener"><strong>Tempco Service</strong></a> team provides technical support for component identification, compatibility verification, and the supply of appropriate spare parts. First, it is necessary to <strong>identify the exchanger model</strong>, which is the basis for any spare parts request.</p>
<p>The <strong>exchanger model</strong> can be found from:</p>
<ul>
<li>Identification plate attached to the exchanger</li>
<li>Technical drawings or thermal calculation sheets</li>
<li>Tempco supply documents</li>
</ul>
<p>It is also helpful to provide:</p>
<ul>
<li>Number of plates installed</li>
<li>Gasket type</li>
<li>Year of supply or serial number</li>
</ul>
<p>The two tables below therefore offer valuable support when requesting <strong>spare parts for heat transfer plates and gaskets</strong>.</p>
<p><img decoding="async" loading="lazy" class="aligncenter wp-image-11314" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-scaled.jpg" alt="Image showing the diagram for selecting spare parts for heat exchange plates in plate heat exchangers." width="651" height="302" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-scaled.jpg 2560w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-300x139.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-1024x475.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-768x357.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-1536x713.jpg 1536w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-2048x951.jpg 2048w" sizes="(max-width: 651px) 100vw, 651px" /></p>
<p><img decoding="async" loading="lazy" class="aligncenter wp-image-11316" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-scaled.jpg" alt="Image showing the diagram for selecting spare parts for gaskets in plate heat exchangers." width="650" height="383" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-scaled.jpg 2560w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-300x177.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-1024x603.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-768x452.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-1536x904.jpg 1536w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-2048x1206.jpg 2048w" sizes="(max-width: 650px) 100vw, 650px" /></p>
<p>Finally, some helpful further tips:</p>
<ul>
<li>Send clear photos of the plates and gaskets for quick identification.</li>
<li>Indicate the process fluid and operating conditions.</li>
<li>Tempco can provide <a href="https://www.tempco.it/blog/en/10096/plate-heat-exchangers-revamping-in-steel-mill/" target="_blank" rel="noopener">plate reconditioning and regeneration</a> with leak testing.</li>
<li>Keeping a <strong>spare set of gaskets</strong> reduces system downtime.</li>
<li>Observe recommended tightening torque values when reassembling.</li>
</ul>
<p>&nbsp;</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11329" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1.jpg" alt="Image showing the Tempco Guide to selecting spare parts for plate heat exchangers." width="650" height="947" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1.jpg 1168w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1-703x1024.jpg 703w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1-1055x1536.jpg 1055w" sizes="(max-width: 650px) 100vw, 650px" /></p>
<p>&nbsp;</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11332" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1.jpg" alt="Image showing the Tempco Guide to selecting spare parts for plate heat exchangers, plates, and gaskets." width="650" height="585" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1.jpg 1168w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1-300x270.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1-1024x921.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1-768x691.jpg 768w" sizes="(max-width: 650px) 100vw, 650px" /></p>
<p>&nbsp;</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/10952/efficiency-and-operational-continuity-original-spare-parts-make-the-difference/" title="Permanent link to Efficiency and operational continuity: original spare parts make the difference">Efficiency and operational continuity: original spare parts make the difference</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10192/importance-of-maintenance-in-plate-heat-exchangers-and-replacement-of-gaskets/" title="Permanent link to Importance of maintenance in plate heat exchangers and replacement of gaskets">Importance of maintenance in plate heat exchangers and replacement of gaskets</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10729/ipe-new-website-for-thermoregulation-services-and-technologies-specialist/" title="Permanent link to IPE, new website for thermoregulation services and technologies specialist">IPE, new website for thermoregulation services and technologies specialist</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8691/service-efficiency-heat-exchangers-and-enjoy-august/" title="Permanent link to Service, efficiency, heat exchangers and… Enjoy August!">Service, efficiency, heat exchangers and… Enjoy August!</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8144/heat-exchangers-regeneration-it-is-not-always-necessary-to-replace-gaskets/" title="Permanent link to Heat exchangers regeneration, it is not always necessary to replace gaskets">Heat exchangers regeneration, it is not always necessary to replace gaskets</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/">Tempco&#8217;s spare parts ordering guide for plate heat exchangers</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-scaled.jpg" medium="image">
			<media:title type="html">Tempco richiesta ricambi scambiatori</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-piastre-scambiatori-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-scaled.jpg" medium="image">
			<media:title type="html">Tempco richiesta ricambi scambiatori guarnizioni</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-richiesta-ricambi-scambiatori-guarnizioni-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1.jpg" medium="image">
			<media:title type="html">Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-1-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1.jpg" medium="image">
			<media:title type="html">Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-manuale-ricambi-scambiatori-a-piastre-rev-2-1-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Modulating power temperature control unit for a pharma reactor</title>
		<link>https://www.tempco.it/blog/en/11296/modulating-power-temperature-control-unit-for-a-pharma-reactor/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 15 May 2026 09:20:45 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[diathermic oil]]></category>
		<category><![CDATA[energy efficiency]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[high temperature]]></category>
		<category><![CDATA[modulating power]]></category>
		<category><![CDATA[pharma]]></category>
		<category><![CDATA[pharmaceutical]]></category>
		<category><![CDATA[reactors]]></category>
		<category><![CDATA[SCR]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[temperature control]]></category>
		<category><![CDATA[temperature control units]]></category>
		<category><![CDATA[temperature regulation]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<category><![CDATA[thyristors]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11296</guid>

					<description><![CDATA[<p>High-temperature diathermic oil temperature control unit, with heating up to 300°C and power modulation using thyristors, for temperature regulation in a pharmaceutical reactor.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11296/modulating-power-temperature-control-unit-for-a-pharma-reactor/">Modulating power temperature control unit for a pharma reactor</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The photos below show a <a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener"><strong>temperature control unit</strong></a> (TCU) for <strong>high-temperature <a href="https://www.tempco.it/blog/en/10155/thermoregulation-unit-with-diathermic-oil-and-first-start-up-service-in-cosmetics/" target="_blank" rel="noopener">diathermic oil</a></strong>, which Tempco deployed and recently delivered to a customer for temperature control in a <a href="https://www.tempco.it/blog/en/10737/chillers-at-20c-for-custom-reactors-thermoregulation-in-pharmaceutical-industry/" target="_blank" rel="noopener"><strong>pharmaceutical reactor</strong></a>.</p>
<p>Precise control of heating and cooling temperature ramps is crucial to achieve the chemical reactions between ingredients in <strong>pharmaceutical production recipes</strong>, essential for the efficacy and quality of the finished products and <a href="https://www.tempco.it/blog/en/8254/thermostatation-of-reactors-in-apis-production/" target="_blank" rel="noopener">active ingredients</a>.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11297" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-1.jpg" alt="The image shows a high-temperature diathermic oil temperature control unit for temperature regulation in a pharmaceutical reactor." width="466" height="563" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-1.jpg 1191w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-1-248x300.jpg 248w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-1-848x1024.jpg 848w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-1-768x928.jpg 768w" sizes="(max-width: 466px) 100vw, 466px" /></p>
<p>This TCU specifically allows to reach a <strong>maximum operating temperature of 300°C</strong>, thanks to an installed heating power of 300 kW equipped with a water-cooled section. The system&#8217;s efficiency is ensured by <strong>modulating power control</strong> in the reactor&#8217;s temperature regulation, achieved thanks to <strong>SCR thyristors</strong>. The TCU is finally equipped with a remote expansion vessel with a capacity of 1,500 liters.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11299" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-olio-diatermico-1.jpg" alt="

The image shows a high-temperature diathermic oil temperature control unit with modulating power and heating up to 300°C for temperature regulation in a pharmaceutical reactor." width="465" height="620" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-olio-diatermico-1.jpg 1191w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-olio-diatermico-1-225x300.jpg 225w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-olio-diatermico-1-768x1023.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-olio-diatermico-1-1153x1536.jpg 1153w" sizes="(max-width: 465px) 100vw, 465px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" title="Permanent link to Temperature control units for reactors at -30° C in the pharma industry">Temperature control units for reactors at -30° C in the pharma industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11051/precise-thermal-control-in-pharmaceutical-research/" title="Permanent link to Precise thermal control in pharmaceutical research">Precise thermal control in pharmaceutical research</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11431/one-fluid-many-temperatures-how-to-regulate-the-temperature-of-a-glass-lined-reactor/" title="Permanent link to One fluid, many temperatures: how to regulate the temperature of a glass-lined reactor">One fluid, many temperatures: how to regulate the temperature of a glass-lined reactor</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11457/design-upon-batch-thermal-duty-changes-the-rules-in-pharma/" title="Permanent link to Design upon ‘batch’: thermal duty changes the rules in pharma">Design upon ‘batch’: thermal duty changes the rules in pharma</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10637/thermoregulation-in-research-and-development-in-pharma-labs/" title="Permanent link to Thermoregulation in research and development in pharma labs">Thermoregulation in research and development in pharma labs</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11296/modulating-power-temperature-control-unit-for-a-pharma-reactor/">Modulating power temperature control unit for a pharma reactor</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-1-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-1.jpg" medium="image">
			<media:title type="html">Tempco centralina termoregolazione TCU reattore farmaceutico</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-centralina-termoregolazione-TCU-reattore-farmaceutico-1-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>PCHE as gas turbine performance heater in oil &#038; gas applications</title>
		<link>https://www.tempco.it/blog/en/11281/pche-as-gas-turbine-performance-heater-in-oil-gas-applications/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 08 May 2026 09:42:49 +0000</pubDate>
				<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Energy Saving]]></category>
		<category><![CDATA[engine preheating]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[compact design]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[engineering]]></category>
		<category><![CDATA[EPC]]></category>
		<category><![CDATA[gas conditioning]]></category>
		<category><![CDATA[gas turbines]]></category>
		<category><![CDATA[H2]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heat recovery]]></category>
		<category><![CDATA[heater]]></category>
		<category><![CDATA[high pressure]]></category>
		<category><![CDATA[hydrogen]]></category>
		<category><![CDATA[intake air heating]]></category>
		<category><![CDATA[jacket water]]></category>
		<category><![CDATA[LNG]]></category>
		<category><![CDATA[OEM]]></category>
		<category><![CDATA[offshore]]></category>
		<category><![CDATA[oil & gas]]></category>
		<category><![CDATA[oil and gas]]></category>
		<category><![CDATA[PCHE]]></category>
		<category><![CDATA[power generation]]></category>
		<category><![CDATA[preheating]]></category>
		<category><![CDATA[pressure drop]]></category>
		<category><![CDATA[skid]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[temperature regulation]]></category>
		<category><![CDATA[thermal control]]></category>
		<category><![CDATA[waste heat recovery]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11281</guid>

					<description><![CDATA[<p>PCHE exchangers as gas turbine performance heater in oil and gas applications to increase performance while ensuring process stability and also leveraging heat recovery for maximum efficiency.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11281/pche-as-gas-turbine-performance-heater-in-oil-gas-applications/">PCHE as gas turbine performance heater in oil &#038; gas applications</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Printed circuit <a href="https://en.tempco.it/solutions-en/heat-exchangers/pche-exchangers/" target="_blank" rel="noopener"><strong>PCHE heat exchangers</strong></a> also find important applications in the <strong>oil and gas sector</strong>, serving as <strong>Gas Turbine Performance Heaters</strong>. This type of application also offers the opportunity to turn <strong>heat recovery into a performance lever</strong>.</p>
<p>Gas turbines are <strong>extremely sensitive to fluid conditions</strong>, in terms of temperature, fluid density, and thermal profile stability. In many industrial applications (power generation, oil and gas, LNG, <strong><a href="https://www.tempco.it/blog/en/10507/innovative-solutions-for-the-hydrogen-industry-from-production-to-storage-and-distribution/" target="_blank" rel="noopener">hydrogen-ready plants</a></strong>), precise control of gas temperature is essential to <strong>improve efficiency</strong>, <strong>reduce operational instabilities</strong>, and protect the equipment during transient conditions. This is where the Gas Turbine Performance Heater is involved.</p>
<p>A Gas Turbine Performance Heater is essentially a <strong>heat exchanger designed for gas preheating</strong> (air, fuel gas, process gas), with a controlled ΔT, high reliability, and often undergoing <strong>high pressure and continuous service</strong>. Typical applications include fuel gas conditioning, intake air heating, and <a href="https://www.tempco.it/blog/en/10163/free-flow-exchangers-for-thermal-energy-recovery-in-the-textile-industry/" target="_blank" rel="noopener"><strong>heat recovery systems</strong></a> from oil/hot water/waste heat recovery circuits.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11282" src="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-PCHE-scambiatori-gas-turbine-performance-heater-oil-ad-gas-1.jpg" alt="AI image illustrating the applications of PCHE exchangers in oil and gas plants as gas turbine performance heater, offering efficiency, compactness, greater operational stability, and increased performance." width="601" height="335" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-PCHE-scambiatori-gas-turbine-performance-heater-oil-ad-gas-1.jpg 1361w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-PCHE-scambiatori-gas-turbine-performance-heater-oil-ad-gas-1-300x167.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-PCHE-scambiatori-gas-turbine-performance-heater-oil-ad-gas-1-1024x571.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-PCHE-scambiatori-gas-turbine-performance-heater-oil-ad-gas-1-768x428.jpg 768w" sizes="(max-width: 601px) 100vw, 601px" /><br />
Tempco proposes <a href="https://pche.it/en/" target="_blank" rel="noopener"><strong>PCHE exchangers</strong></a> as particularly suited to this role, as they offer significant key advantages over traditional shell-and-tube solutions:</p>
<ul>
<li>Extremely compact</li>
<li>Resistance to high pressures (tens/hundreds of bar)</li>
<li>Perfect thermal stability even with rapid gradients</li>
<li>Minimal fluid accumulation → safety + fast response</li>
<li>Channel geometry optimizable upon the actual operating point</li>
</ul>
<p>In <strong>performance-driven turbine applications</strong>, this makes the difference.</p>
<p><em>PCHE + Turbine: a smart technical marriage</em><br />
As a performance heater, the PCHE allows:</p>
<ul>
<li>very precise control of the inlet gas temperature</li>
<li>low pressure drops (if properly designed)</li>
<li>easy integration into compact skids</li>
<li>reliable operation even in:<br />
◦ offshore environments<br />
◦ frequent start/stop cycles<br />
◦ severe conditions (H₂ blend, dry gases, LNG boil-off)</li>
</ul>
<p>When the focus is <strong>performance + reliability</strong>, the PCHE is often the most engineered choice, not just the most compact.</p>
<p>A double advantage is therefore achieved when <strong>increased performance is achieved by implementing a heat recovery system</strong>, and this is where the application becomes very interesting, when the PCHE is served by:</p>
<ul>
<li>heat recovery circuits</li>
<li>jacket water</li>
<li>hot oil</li>
<li>process waste heat</li>
</ul>
<p>The result is an <strong>increase in the overall efficiency of the system</strong>, a reduction in auxiliary consumption, and improved operational control of the turbine.</p>
<p>Tempco therefore positions itself as a strategic technology partner for the development and implementation of this type of application, providing not only the technology but also <strong>support for the engineering</strong>, in defining the actual duty cycle and <strong>verifying turbine-side pressure drops</strong> &#8211; a highly critical issue &#8211; and then ensuring the integration of PCHEs into complete skids and technical dialogue with EPCs and turbine OEMs. The PCHE is not a standard component, but a solution tailored to the plant.</p>
<p>In conclusion, the use of PCHEs as Gas Turbine Performance Heaters represents a natural, highly innovative evolution of high-performance applications in the oil and gas sector, effectively addressing the <strong>needs for compactness, safety, and control</strong>. Representing a perfect example of applied thermal engineering as a special and customized, non-standard solution.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9796/tempco-green-a-new-thermal-energy-for-a-solid-sustainability/" title="Permanent link to Tempco Green, a new thermal energy for a solid sustainability">Tempco Green, a new thermal energy for a solid sustainability</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/5791/cool-wishes-from-tempco/" title="Permanent link to Cool Wishes from Tempco!">Cool Wishes from Tempco!</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/6588/thermal-energy-and-industrial-processes-a-guide/" title="Permanent link to Thermal energy and industrial processes, a guide">Thermal energy and industrial processes, a guide</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8550/preventive-maintenance-for-heat-exchangers-efficiency/" title="Permanent link to Preventive maintenance for heat exchangers efficiency">Preventive maintenance for heat exchangers efficiency</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11281/pche-as-gas-turbine-performance-heater-in-oil-gas-applications/">PCHE as gas turbine performance heater in oil &#038; gas applications</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-PCHE-scambiatori-gas-turbine-performance-heater-oil-ad-gas-1-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-PCHE-scambiatori-gas-turbine-performance-heater-oil-ad-gas-1.jpg" medium="image">
			<media:title type="html">Tempco PCHE scambiatori gas turbine performance heater oil ad gas</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/05/Tempco-PCHE-scambiatori-gas-turbine-performance-heater-oil-ad-gas-1-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Thermoregulation for custom carbon fiber components</title>
		<link>https://www.tempco.it/blog/en/11271/thermoregulation-for-custom-carbon-fiber-components/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 30 Apr 2026 09:36:10 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[automotive]]></category>
		<category><![CDATA[carbon fiber]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[customization]]></category>
		<category><![CDATA[design for manufacturing]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[high performance cars]]></category>
		<category><![CDATA[mechanical resistance]]></category>
		<category><![CDATA[molding]]></category>
		<category><![CDATA[motorsport]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[supercar]]></category>
		<category><![CDATA[supercars]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[temperature control]]></category>
		<category><![CDATA[temperature control units]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11271</guid>

					<description><![CDATA[<p>Tempco temperature control unit for thermal control in the molding of carbon fiber parts for high-performance vehicles. Temperature regulation is essential for the material's properties.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11271/thermoregulation-for-custom-carbon-fiber-components/">Thermoregulation for custom carbon fiber components</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><a href="https://www.tempco.it/blog/en/10503/thermoregulation-in-carbon-fiber-composite-materials-molding/" target="_blank" rel="noopener">Carbon fiber parts</a> molding</strong> is a manufacturing process that involves special attention to temperature regulation, requiring high levels of <strong>precision and reliability in thermal control</strong> to ensure material quality and high mechanical and structural performances.</p>
<p>Tempco already has several applications of <a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener"><strong>temperature control units</strong></a> designed to meet the specific thermoregulation needs of molding carbon fiber components. The unit pictured below is a temperature control unit we recently supplied to a company in the province of Bergamo, specializing in the production of custom carbon fiber components for <a href="https://www.tempco.it/blog/en/9418/carbon-fiber-and-temperature-control-in-dallara-supercars/" target="_blank" rel="noopener"><strong>high-performance vehicles</strong></a> as well as other applications.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11272" src="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centralina-termoregolazione-TCU-stampaggio-fibra-di-carbonio-1.jpg" alt="Image showing a Tempco temperature control unit for thermal control in the molding of carbon fiber parts for high-performance vehicles." width="571" height="454" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centralina-termoregolazione-TCU-stampaggio-fibra-di-carbonio-1.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centralina-termoregolazione-TCU-stampaggio-fibra-di-carbonio-1-300x238.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centralina-termoregolazione-TCU-stampaggio-fibra-di-carbonio-1-768x610.jpg 768w" sizes="(max-width: 571px) 100vw, 571px" /></p>
<p>Tempco&#8217;s TCUs have a wide range of applications in the <strong>automotive sector</strong>, supporting our clients in defining the design and engineering process using a DFM (<strong>Design for Manufacturing</strong>) approach, aimed at achieving an ideal balance and harmony on both fronts. Maximizing aesthetic appeal while simultaneously <strong>enhancing the mechanical and structural performance</strong> of the components.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/10503/thermoregulation-in-carbon-fiber-composite-materials-molding/" title="Permanent link to Thermoregulation in carbon fiber composite materials molding">Thermoregulation in carbon fiber composite materials molding</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10387/strength-and-resistance-with-thermoregulation-in-carbon-fiber-production/" title="Permanent link to Strength and resistance with thermoregulation in carbon fiber production">Strength and resistance with thermoregulation in carbon fiber production</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9418/carbon-fiber-and-temperature-control-in-dallara-supercars/" title="Permanent link to Carbon fiber and temperature control in Dallara supercars">Carbon fiber and temperature control in Dallara supercars</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11344/ul-certified-temperature-control-unit-for-carbon-fiber-impregnation/" title="Permanent link to UL-certified temperature control unit for carbon fiber impregnation">UL-certified temperature control unit for carbon fiber impregnation</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" title="Permanent link to Temperature control units for reactors at -30° C in the pharma industry">Temperature control units for reactors at -30° C in the pharma industry</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11271/thermoregulation-for-custom-carbon-fiber-components/">Thermoregulation for custom carbon fiber components</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centralina-termoregolazione-TCU-stampaggio-fibra-di-carbonio-1-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centralina-termoregolazione-TCU-stampaggio-fibra-di-carbonio-1.jpg" medium="image">
			<media:title type="html">Tempco centralina termoregolazione TCU stampaggio fibra di carbonio</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centralina-termoregolazione-TCU-stampaggio-fibra-di-carbonio-1-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Temperature control units in high-efficiency combustion engine test benches</title>
		<link>https://www.tempco.it/blog/en/11236/temperature-control-units-in-high-efficiency-combustion-engine-test-benches/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 17 Apr 2026 10:21:19 +0000</pubDate>
				<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[engine preheating]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[automotive]]></category>
		<category><![CDATA[combustion]]></category>
		<category><![CDATA[combustion engines]]></category>
		<category><![CDATA[diesel]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[emissions reduction]]></category>
		<category><![CDATA[engines]]></category>
		<category><![CDATA[exchangers]]></category>
		<category><![CDATA[flow bench]]></category>
		<category><![CDATA[fuels]]></category>
		<category><![CDATA[gasoline]]></category>
		<category><![CDATA[Gasoline Compression Ignition]]></category>
		<category><![CDATA[GCI]]></category>
		<category><![CDATA[GDI]]></category>
		<category><![CDATA[Giacomo Silvagni]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[hydraulics]]></category>
		<category><![CDATA[industrial engineering]]></category>
		<category><![CDATA[injection systems]]></category>
		<category><![CDATA[injectors]]></category>
		<category><![CDATA[multijet]]></category>
		<category><![CDATA[research]]></category>
		<category><![CDATA[solid sustainability]]></category>
		<category><![CDATA[sustainable mobility]]></category>
		<category><![CDATA[synthetic fuels]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[Tempco Green]]></category>
		<category><![CDATA[temperature control units]]></category>
		<category><![CDATA[test benches]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<category><![CDATA[University of Bologna]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11236</guid>

					<description><![CDATA[<p>Tempco TREG temperature control units used in test benches built at the University of Bologna for the study of high-efficiency combustion techniques in traditional gasoline and diesel engines.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11236/temperature-control-units-in-high-efficiency-combustion-engine-test-benches/">Temperature control units in high-efficiency combustion engine test benches</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>We are pleased to present two important applications of our Tempco <a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener"><strong>TREG temperature control units</strong></a>, which we have supplied within the last years to the <strong>Department of Industrial Engineering at the University of Bologna</strong>. These units are used in <a href="https://www.tempco.it/blog/en/10462/diverse-and-various-applications-of-thermoregulating-units-in-test-benches/" target="_blank" rel="noopener"><strong>test benches</strong></a> as part of research and development to <strong>improve the efficiency of combustion techniques in traditional engines</strong>, with the aim of increasing the sustainability of internal combustion engines, especially looking forward at the growing use of <strong>new synthetic fuels</strong>.</p>
<p>These activities are crucial for the <strong>future of sustainable mobility</strong>, essential for the development of more sustainable technologies for the future of the automotive industry. We therefore extend our sincere thanks to <strong>Giacomo Silvagni</strong>, PhD Assistant Professor at Alma Mater Studiorum &#8211; University of Bologna, responsible for these projects at the University Department, who provided us with detailed information on two of the ongoing research projects.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11237" src="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-efficienza-motori-combustione-1.jpg" alt="Image showing Tempco TCU temperature control units for test bench applications" width="510" height="612" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-efficienza-motori-combustione-1.jpg 978w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-efficienza-motori-combustione-1-250x300.jpg 250w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-efficienza-motori-combustione-1-853x1024.jpg 853w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-efficienza-motori-combustione-1-768x922.jpg 768w" sizes="(max-width: 510px) 100vw, 510px" /></p>
<p>The first image, in the scheme below, shows the construction of a <strong>flow bench for experimental diesel and gasoline</strong> common rail GDI (Gasoline Direct Injection) <strong>injectors</strong>, aimed at hydraulic characterization of the injection system and the development of control-oriented models.</p>
<p>As Giacomo Silvagni explains, high-pressure injection systems are typically used in control strategies with multiple, closely spaced injections. These strategies generate <strong>dynamic pressure wave effects and electromagnetic interactions</strong> that induce deviations from the normal injector operation, causing <strong>imbalances in the torque</strong> delivered by the engine from cylinder to cylinder, resulting in reduced efficiency and increased pollutant emissions. Thanks to the flow bench, built within the laboratories of the Department of Industrial Engineering of the University of Bologna, it was possible to carry out ad hoc experimental campaigns to <strong>experimentally characterize the tested injection systems</strong>, both <strong>diesel</strong> (up to 1,800 bar) and <strong>gasoline</strong> (up to 700 bar), and to develop control-oriented physical models aimed at <strong>real-time compensation of these dynamic phenomena</strong> compatible with standard engine control units.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11239" src="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-iniettori-UniBo-1-1.jpg" alt="Image showing the construction scheme of a flow test bench with a Tempco TCU temperature control unit for the study of high-pressure injection systems for high-efficiency combustion engines." width="660" height="284" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-iniettori-UniBo-1-1.jpg 966w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-iniettori-UniBo-1-1-300x129.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-iniettori-UniBo-1-1-768x331.jpg 768w" sizes="(max-width: 660px) 100vw, 660px" /></p>
<p>For this first application, the Tempco temperature control unit was a central component of the test system, used to <strong>regulate the fuel temperature within the injection systems</strong>. The TCU therefore allowed for precise control of the fluid temperature, which is crucial for ensuring the <strong>repeatability of the experimental tests</strong>, and simultaneously verified the impact of different fuel temperatures on the system&#8217;s hydraulic dynamics.</p>
<p>The other two images below relate to the study for <strong>converting a 1.3-liter multijet diesel engine</strong> to operate on <strong>compression-ignition gasoline</strong>, aimed at studying high-efficiency combustion modes.</p>
<p>The study of <strong>innovative, high-efficiency, low-emission combustion methods</strong> is part of the ongoing development of internal combustion engines for high-efficiency, low-emission applications. Innovative combustion methods still represent one of the most promising solutions, especially considering the advent of <strong>synthetic and sustainable fuels</strong>. To verify the benefits of these technologies, a small 1.3-liter multijet internal combustion engine, originally designed for diesel compression ignition, was <strong>converted to GCI</strong> (Gasoline Compression Ignition) operation in the laboratories of the Department of Industrial Engineering at the University of Bologna. This activity allowed to verify the benefits of this combustion method, both in terms of efficiency and pollutant emissions, compared to traditional diesel operation. The entire engine operating range was replicated while <strong>maintaining all internal engine components in their stock production configuration</strong>, thus verifying their full applicability to off-the-shelf hardware already on the market.</p>
<p><img decoding="async" loading="lazy" class="aligncenter size-full wp-image-11241" src="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-UniBo-1.jpg" alt="Image showing the construction scheme of a test bench with a Tempco TCU temperature control unit for the study of innovative, high-efficiency combustion methods as alternatives to traditional diesel technologies." width="574" height="379" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-UniBo-1.jpg 574w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-UniBo-1-300x198.jpg 300w" sizes="(max-width: 574px) 100vw, 574px" /></p>
<p>The Tempco temperature control unit, as Silvagni further explains, was a central element of the test system as it was used to <strong>regulate the temperature of the air drawn into the engine</strong> during start-up. Thanks to the Tempco temperature control unit and the use of a <strong>dedicated air-oil <a href="https://en.tempco.it/solutions-en/heat-exchangers/" target="_blank" rel="noopener">heat exchanger</a></strong>, it was possible to increase the temperature of the air drawn into the engine before it entered the combustion chamber, thus promoting <strong>spontaneous ignition of the gasoline</strong>. The precise control achieved by the Tempco system also allowed to verify the <strong>impact of different combustion air temperatures on combustion stability and engine performance</strong> in terms of torque/power output and pollutant emissions.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11243" src="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-basse-emissioni-UniBo-1.jpg" alt="Image showing the test bench with a Tempco TREG temperature control unit built at the University of Bologna for the study of innovative, high-efficiency combustion methods as alternatives to traditional diesel technologies." width="551" height="412" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-basse-emissioni-UniBo-1.jpg 870w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-basse-emissioni-UniBo-1-300x224.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-basse-emissioni-UniBo-1-768x575.jpg 768w" sizes="(max-width: 551px) 100vw, 551px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11098/thermal-control-unit-for-radiators-test-bench-in-dallara-automobili/" title="Permanent link to Thermal control unit for radiators test bench in Dallara Automobili">Thermal control unit for radiators test bench in Dallara Automobili</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10426/treg-thermoregulation-units-in-automotive-and-ev-test-benches/" title="Permanent link to TREG thermoregulation units in automotive and EV test benches">TREG thermoregulation units in automotive and EV test benches</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/6325/thermoregulation-in-automotive-engines-test-bench-controls/" title="Permanent link to Thermoregulation in automotive engines test bench controls">Thermoregulation in automotive engines test bench controls</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" title="Permanent link to Temperature control units for reactors at -30° C in the pharma industry">Temperature control units for reactors at -30° C in the pharma industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11281/pche-as-gas-turbine-performance-heater-in-oil-gas-applications/" title="Permanent link to PCHE as gas turbine performance heater in oil &#038; gas applications">PCHE as gas turbine performance heater in oil &#038; gas applications</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11236/temperature-control-units-in-high-efficiency-combustion-engine-test-benches/">Temperature control units in high-efficiency combustion engine test benches</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-efficienza-motori-combustione-1-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-efficienza-motori-combustione-1.jpg" medium="image">
			<media:title type="html">Tempco centraline TREG banchi prova ricerca efficienza motori combustione</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-efficienza-motori-combustione-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-iniettori-UniBo-1-1.jpg" medium="image">
			<media:title type="html">Tempco centraline TREG banchi prova ricerca iniettori UniBo</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-iniettori-UniBo-1-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-UniBo-1.jpg" medium="image">
			<media:title type="html">Tempco centraline TREG banchi prova ricerca motori combustione alta efficienza UniBo</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-UniBo-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-basse-emissioni-UniBo-1.jpg" medium="image">
			<media:title type="html">Tempco centraline TREG banchi prova ricerca motori combustione alta efficienza basse emissioni UniBo</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-TREG-banchi-prova-ricerca-motori-combustione-alta-efficienza-basse-emissioni-UniBo-1-150x150.jpg" />
		</media:content>
	</item>
		<item>
		<title>Temperature control units for reactors at -30° C in the pharma industry</title>
		<link>https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 10 Apr 2026 09:45:27 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[API]]></category>
		<category><![CDATA[brazed plate]]></category>
		<category><![CDATA[chemical industry]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[exchangers]]></category>
		<category><![CDATA[low temperature]]></category>
		<category><![CDATA[magnetic drive pumps]]></category>
		<category><![CDATA[modulating power]]></category>
		<category><![CDATA[pharmaceutical]]></category>
		<category><![CDATA[reactors]]></category>
		<category><![CDATA[silicone fluids]]></category>
		<category><![CDATA[single-fluid]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[temperature control]]></category>
		<category><![CDATA[temperature control units]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<category><![CDATA[thermostating]]></category>
		<category><![CDATA[thyristors]]></category>
		<category><![CDATA[TREG]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11220</guid>

					<description><![CDATA[<p>Tempco single-fluid temperature control units for applications in the chemical and pharmaceutical industries, for thermostating glass-lined reactors with wide temperature ranges from -30 to +300°C.</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/">Temperature control units for reactors at -30° C in the pharma industry</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Within the last few months, Tempco have supplied several <a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener"><strong>TREG temperature control units</strong></a> and temperature control solutions for a variety of applications in the <a href="https://www.tempco.it/blog/en/8254/thermostatation-of-reactors-in-apis-production/" target="_blank" rel="noopener"><strong>chemical industry</strong></a>, specifically a <strong>-30° C chiller</strong> for temperature control in the production processes of new products, and in the <strong>pharmaceutical sector</strong>, with plate heat exchangers for <a href="https://www.tempco.it/blog/en/8542/high-precision-thermoregulation-in-mono-fluid-mode/" target="_blank" rel="noopener">mono-fluid thermostating</a> of several reactors at -25°C, for a major Italian API manufacturing group that already employs Tempco temperature control systems for the temperature recipes of its <a href="https://www.tempco.it/blog/en/8335/thermoregulating-units-for-reactors-in-the-usa/" target="_blank" rel="noopener"><strong>production reactors</strong></a>.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11221" src="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-1.jpg" alt="Image showing some Tempco TREG and TCU temperature control units supplied for mono-fluid thermostating of reactors in the chemical and pharmaceutical industries." width="530" height="397" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-1.jpg 1304w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-1-300x225.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-1-1024x768.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-1-768x576.jpg 768w" sizes="(max-width: 530px) 100vw, 530px" /></p>
<p>Also for pharmaceutical applications, we recently supplied three TREG temperature control units for <strong>silicone fluids in glass-lined reactors</strong>. This is a classic mono-fluid temperature control application, equipped with heating via electric resistors and a <strong>low-temperature cooling section</strong> (<strong>-30°C</strong>) using <a href="https://en.tempco.it/solutions-en/heat-exchangers/brazed-plate/" target="_blank" rel="noopener">brazed plate heat exchangers</a> and mixing valves.</p>
<p><img decoding="async" loading="lazy" class="aligncenter  wp-image-11223" src="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-reattori-smaltati-1.jpg" alt="AI image illustrating a typical application in the pharmaceutical industry of Tempco TREG temperature control units for mono-fluid thermostating of production reactors." width="530" height="708" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-reattori-smaltati-1.jpg 1020w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-reattori-smaltati-1-225x300.jpg 225w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-reattori-smaltati-1-767x1024.jpg 767w, https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-reattori-smaltati-1-768x1025.jpg 768w" sizes="(max-width: 530px) 100vw, 530px" /></p>
<p>Temperature ramps control is achieved through dedicated electronic thermoregulators and <strong>thyristors</strong> (SCR), which allow the customer to <strong>drive the heating elements with modulating power</strong>. Finally, the thermal control units work with special pumps, featuring magnetic drive technology and a very <strong>wide temperature range of -30/+300° C</strong>.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8542/high-precision-thermoregulation-in-mono-fluid-mode/" title="Permanent link to High precision thermoregulation in mono fluid mode">High precision thermoregulation in mono fluid mode</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10896/precision-and-hygiene-in-stainless-steel-for-pharma-and-food-thermoregulation/" title="Permanent link to Precision and hygiene in stainless steel for pharma and food thermoregulation">Precision and hygiene in stainless steel for pharma and food thermoregulation</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8335/thermoregulating-units-for-reactors-in-the-usa/" title="Permanent link to Thermoregulating units for reactors in the USA">Thermoregulating units for reactors in the USA</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/5984/temperature-control-in-pharmaceutical-preparers/" title="Permanent link to Temperature control in pharmaceutical preparers">Temperature control in pharmaceutical preparers</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/">Temperature control units for reactors at -30° C in the pharma industry</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-1-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-1.jpg" medium="image">
			<media:title type="html">Tempco centraline termoregolazione TCU farmaceutico</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-1-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-reattori-smaltati-1.jpg" medium="image">
			<media:title type="html">Tempco centraline termoregolazione TCU farmaceutico reattori smaltati</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2026/04/Tempco-centraline-termoregolazione-TCU-farmaceutico-reattori-smaltati-1-150x150.jpg" />
		</media:content>
	</item>
	</channel>
</rss>
