<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:media="http://search.yahoo.com/mrss/"
	>

<channel>
	<title>cryogenic Archivi - Tempco Blog</title>
	<atom:link href="https://www.tempco.it/blog/en/category/cryogenic/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.tempco.it/blog/en/category/cryogenic/</link>
	<description>Solutions for the thermal energy</description>
	<lastBuildDate>Fri, 10 Feb 2017 14:21:32 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.8</generator>
	<item>
		<title>Chillers -30°C in pharma industry</title>
		<link>https://www.tempco.it/blog/en/5825/chillers-30c-in-pharma-industry/</link>
					<comments>https://www.tempco.it/blog/en/5825/chillers-30c-in-pharma-industry/#respond</comments>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 10 Feb 2017 14:21:32 +0000</pubDate>
				<category><![CDATA[Chiller]]></category>
		<category><![CDATA[Cooling]]></category>
		<category><![CDATA[cryogenic]]></category>
		<category><![CDATA[aerosol]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[compressors]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[extreme low temperatures]]></category>
		<category><![CDATA[insulation]]></category>
		<category><![CDATA[monitoring]]></category>
		<category><![CDATA[pharma]]></category>
		<category><![CDATA[pumps]]></category>
		<category><![CDATA[refrigeration]]></category>
		<category><![CDATA[remote control]]></category>
		<category><![CDATA[stainless steel]]></category>
		<category><![CDATA[Tempco]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/en/?p=5825</guid>

					<description><![CDATA[<p>Recently in Tempco we’ve developed a refrigeration solution for near-cryogenic temperatures supplied to a customer in the pharma sector, aimed [&#8230;]</p>
<p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/5825/chillers-30c-in-pharma-industry/">Chillers -30°C in pharma industry</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Recently in <a href="http://en.tempco.it/" target="_blank">Tempco</a> we’ve developed a <strong><a href="http://en.tempco.it/solutions-en/chillers/" target="_blank">refrigeration</a> solution for near-cryogenic temperatures</strong> supplied to a customer in the <a href="http://en.tempco.it/solutions-en/special-applications-en/chemistry-pharmaceutical/" target="_blank"><strong>pharma</strong></a> sector, aimed to cool down to -25°C the reactor employed in the production of the active ingredient of an innovative aerosol.</p>
<p><a href="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-pharma-chiller-30.jpg"><img decoding="async" loading="lazy" class="aligncenter size-full wp-image-5822" src="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-pharma-chiller-30.jpg" alt="chiller pharma Tempco" width="1134" height="864" srcset="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-pharma-chiller-30.jpg 1134w, https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-pharma-chiller-30-300x229.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-pharma-chiller-30-1024x780.jpg 1024w" sizes="(max-width: 1134px) 100vw, 1134px" /></a></p>
<p>After a careful evaluation of the overall process, we came with the proposition of two alternative solutions:</p>
<ul>
<li>A liquid nitrogen cooling system</li>
<li>A classic <strong>compressor <a href="http://en.tempco.it/solutions-en/chillers/" target="_blank">chillers</a></strong> solution</li>
</ul>
<p>The solution using chillers was the preferred one, due to its technical advantages and the easier management. We agreed with the customer to develop a system employing <strong>two chillers</strong> working in parallel, each one achieving 75% of the total duty required.<br />
The <strong>cooling capacity of each chiller is -30°C</strong>, and an automatic regulation system of the condensation ensures the best process efficiency in every season, an essential requirement because the plant is always operating.</p>
<p><a href="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-chiller-pharma-30.jpg"><img decoding="async" loading="lazy" class="aligncenter size-full wp-image-5823" src="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-chiller-pharma-30.jpg" alt="chiller Tempco pharma -30" width="1417" height="1063" srcset="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-chiller-pharma-30.jpg 1417w, https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-chiller-pharma-30-300x225.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-chiller-pharma-30-1024x768.jpg 1024w" sizes="(max-width: 1417px) 100vw, 1417px" /></a></p>
<p>The full stainless realization steel has a special <strong>insulation for extreme low temperatures</strong>. A storage and distributing skid was built inside the building of the customer, providing the reactor the non-freezing solution, and equipped with:</p>
<ul>
<li>Storage tanks</li>
<li>Redundant pumps</li>
<li><strong>Monitoring and management</strong> centralized system</li>
</ul>
<p>The remote management from a control-room allows monitoring and piloting of both chillers and pumps, with the possibility to manage alarms in order to ensure maximum productivity and to avoid expensive downtimes.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/7898/near-cryogenic-cooling-in-pharma-production/" title="Permanent link to Near-cryogenic cooling in pharma production">Near-cryogenic cooling in pharma production</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/5984/temperature-control-in-pharmaceutical-preparers/" title="Permanent link to Temperature control in pharmaceutical preparers">Temperature control in pharmaceutical preparers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10449/chiller-at-30-c-for-high-precision-cooling-in-pharma-production/" title="Permanent link to Chiller at -30° C for high precision cooling in pharma production">Chiller at -30° C for high precision cooling in pharma production</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8156/monofluid-thermoregulation-in-pharma-group-for-api-production/" title="Permanent link to Monofluid thermoregulation in pharma Group for API production">Monofluid thermoregulation in pharma Group for API production</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10792/custom-thermoregulation-units-for-oems-in-the-food-pharma-sectors/" title="Permanent link to Custom thermoregulation units for OEMs in the food &#038; pharma sectors">Custom thermoregulation units for OEMs in the food &#038; pharma sectors</a>  </li>
</ol></div><p>L'articolo <a rel="nofollow" href="https://www.tempco.it/blog/en/5825/chillers-30c-in-pharma-industry/">Chillers -30°C in pharma industry</a> proviene da <a rel="nofollow" href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.tempco.it/blog/en/5825/chillers-30c-in-pharma-industry/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		
		<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-pharma-chiller-30-150x150.jpg" />
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-pharma-chiller-30.jpg" medium="image">
			<media:title type="html">Tempco pharma chiller -30</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-pharma-chiller-30-150x150.jpg" />
		</media:content>
		<media:content url="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-chiller-pharma-30.jpg" medium="image">
			<media:title type="html">Tempco chiller pharma -30</media:title>
			<media:thumbnail url="https://www.tempco.it/blog/wp-content/uploads/2017/02/Tempco-chiller-pharma-30-150x150.jpg" />
		</media:content>
	</item>
	</channel>
</rss>