{"id":219,"date":"2008-02-22T18:41:12","date_gmt":"2008-02-22T16:41:12","guid":{"rendered":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/"},"modified":"2008-02-22T18:41:12","modified_gmt":"2008-02-22T16:41:12","slug":"fouling-factor-fattore-di-sporcamento","status":"publish","type":"post","link":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/","title":{"rendered":"Fouling factor, fattore di sporcamento"},"content":{"rendered":"<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2008\/02\/dscf2276.JPG\" title=\"Scambiatore di calore intasato\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2008\/02\/dscf2276.thumbnail.JPG\" alt=\"Scambiatore di calore intasato\" \/><\/a><\/p>\n<p>Il <a href=\"http:\/\/en.wikipedia.org\/wiki\/Fouling\">fouling factor o fattore di sporcamento<\/a> \u00e8 un coefficiente molto importante nel dimensionamento delle macchine termiche.<\/p>\n<p>Infatti in funzione di tale coefficiente, gli scambiatori di calore risulteranno pi\u00f9 o meno sovradimensionati (pi\u00f9 grandi o meno grandi) rispetto ai dati nominali di progetto.<\/p>\n<p>Il fattore di sporcamento \u00e8 funzione:<\/p>\n<ul>\n<li>del tipo di fluido utilizzato per il trasferimento del calore<\/li>\n<li>del tipo di apparecchiatura (scambiatore di calore)<\/li>\n<\/ul>\n<p><!--more-->Infatti senel primo caso \u00e8 logico capirne le cause, acqua pi\u00f9 o meno sporca, particelle in sospensione ecc&#8230;, nel caso del tipo di scambiatore, dipende da diversi fattori quali:<\/p>\n<ul>\n<li>velocit\u00e0 del fluido (numero di reynolds)<\/li>\n<li>tipo di moto (laminare o turbolento)<\/li>\n<li>sforzi di taglio<\/li>\n<li>design termico<\/li>\n<\/ul>\n<p>A questo link potete trovare una semplice tabella con i valori di <a href=\"http:\/\/www.tempco.it\/static\/images\/pdf\/Fattori%20di%20sporcamento.pdf\" class=\"broken_link\">fouling factor tipici per i fluidi pi\u00f9 comunemente utilizzati<\/a>.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2008\/02\/mvc-692x.JPG\" title=\"Scambiatore di calore pulito\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2008\/02\/mvc-692x.thumbnail.JPG\" alt=\"Scambiatore di calore pulito\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Il fouling factor o fattore di sporcamento \u00e8 un coefficiente molto importante nel dimensionamento delle macchine termiche. Infatti in funzione [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,13,4,5,9],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Fouling factor, fattore di sporcamento - Tempco Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fouling factor, fattore di sporcamento - Tempco Blog\" \/>\n<meta property=\"og:description\" content=\"Il fouling factor o fattore di sporcamento \u00e8 un coefficiente molto importante nel dimensionamento delle macchine termiche. Infatti in funzione [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/\" \/>\n<meta property=\"og:site_name\" content=\"Tempco Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tempco.srl\" \/>\n<meta property=\"article:published_time\" content=\"2008-02-22T16:41:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2008\/02\/dscf2276.thumbnail.JPG\" \/>\n<meta name=\"author\" content=\"Valter Biolchi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:site\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Valter Biolchi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/\"},\"author\":{\"name\":\"Valter Biolchi\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1\"},\"headline\":\"Fouling factor, fattore di sporcamento\",\"datePublished\":\"2008-02-22T16:41:12+00:00\",\"dateModified\":\"2008-02-22T16:41:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/\"},\"wordCount\":135,\"commentCount\":5,\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"articleSection\":[\"Energia Termica\",\"Manutenzione\",\"Raffreddamento\",\"Riscaldamento\",\"Scambiatori di calore\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/\",\"name\":\"Fouling factor, fattore di sporcamento - Tempco Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\"},\"datePublished\":\"2008-02-22T16:41:12+00:00\",\"dateModified\":\"2008-02-22T16:41:12+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tempco.it\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fouling factor, fattore di sporcamento\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"name\":\"Tempco Blog\",\"description\":\"Soluzioni per l&#039;energia termica\",\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tempco.it\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\",\"name\":\"Tempco Srl\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"contentUrl\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"width\":317,\"height\":317,\"caption\":\"Tempco Srl\"},\"image\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tempco.srl\",\"https:\/\/twitter.com\/Tempco_it\",\"https:\/\/www.youtube.com\/c\/TempcoItalia\",\"https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/\",\"https:\/\/www.instagram.com\/tempco_solidtemperature\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1\",\"name\":\"Valter Biolchi\",\"sameAs\":[\"http:\/\/www.tempco.it\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fouling factor, fattore di sporcamento - Tempco Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/","og_locale":"it_IT","og_type":"article","og_title":"Fouling factor, fattore di sporcamento - Tempco Blog","og_description":"Il fouling factor o fattore di sporcamento \u00e8 un coefficiente molto importante nel dimensionamento delle macchine termiche. Infatti in funzione [&hellip;]","og_url":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/","og_site_name":"Tempco Blog","article_publisher":"https:\/\/www.facebook.com\/tempco.srl","article_published_time":"2008-02-22T16:41:12+00:00","og_image":[{"url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2008\/02\/dscf2276.thumbnail.JPG"}],"author":"Valter Biolchi","twitter_card":"summary_large_image","twitter_creator":"@Tempco_it","twitter_site":"@Tempco_it","twitter_misc":{"Scritto da":"Valter Biolchi","Tempo di lettura stimato":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/#article","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/"},"author":{"name":"Valter Biolchi","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1"},"headline":"Fouling factor, fattore di sporcamento","datePublished":"2008-02-22T16:41:12+00:00","dateModified":"2008-02-22T16:41:12+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/"},"wordCount":135,"commentCount":5,"publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"articleSection":["Energia Termica","Manutenzione","Raffreddamento","Riscaldamento","Scambiatori di calore"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/","url":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/","name":"Fouling factor, fattore di sporcamento - Tempco Blog","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/#website"},"datePublished":"2008-02-22T16:41:12+00:00","dateModified":"2008-02-22T16:41:12+00:00","breadcrumb":{"@id":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.tempco.it\/blog\/219\/fouling-factor-fattore-di-sporcamento\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tempco.it\/blog\/"},{"@type":"ListItem","position":2,"name":"Fouling factor, fattore di sporcamento"}]},{"@type":"WebSite","@id":"https:\/\/www.tempco.it\/blog\/#website","url":"https:\/\/www.tempco.it\/blog\/","name":"Tempco Blog","description":"Soluzioni per l&#039;energia termica","publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tempco.it\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/www.tempco.it\/blog\/#organization","name":"Tempco Srl","url":"https:\/\/www.tempco.it\/blog\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","contentUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","width":317,"height":317,"caption":"Tempco Srl"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tempco.srl","https:\/\/twitter.com\/Tempco_it","https:\/\/www.youtube.com\/c\/TempcoItalia","https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/","https:\/\/www.instagram.com\/tempco_solidtemperature\/"]},{"@type":"Person","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1","name":"Valter Biolchi","sameAs":["http:\/\/www.tempco.it"]}]}},"_links":{"self":[{"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/posts\/219"}],"collection":[{"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/comments?post=219"}],"version-history":[{"count":0,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/posts\/219\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/media?parent=219"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/categories?post=219"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/tags?post=219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}