{"id":135,"date":"2007-11-22T11:04:41","date_gmt":"2007-11-22T09:04:41","guid":{"rendered":"https:\/\/www.tempco.it\/blog\/135\/meglio-uno-grande-o-due-tre-quattro-piu-piccoli\/"},"modified":"2011-03-03T15:54:38","modified_gmt":"2011-03-03T13:54:38","slug":"chiller-grande-piccolo","status":"publish","type":"post","link":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/","title":{"rendered":"Meglio un refrigeratore grande o due (tre, quattro&#8230;), pi\u00f9 piccoli?"},"content":{"rendered":"<p><a title=\"Chiller refrigeratori 2\" href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/dscf0758.JPG\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/dscf0758.thumbnail.JPG\" alt=\"Chiller refrigeratori 2\" \/><\/a><\/p>\n<p>Meglio uno grande o due (tre, quattro&#8230;), pi\u00f9 piccoli?<\/p>\n<p>Mi riferisco ovviamente alle macchine frigorifere che raffreddano un processo industriale.<\/p>\n<p>In pratica spesso i clienti mi rivolgono questa fatidica domanda:<\/p>\n<blockquote><p>\u00e8 meglio avere un unico chiller, torre evaporative, scambiatore&#8230;che soddisfa la duty al 100%, oppure meglio scegliere una soluzione di due macchine al 50%?<\/p><\/blockquote>\n<p>La risposta \u00e8 soggettiva e dipende anche dalla tipologia di impianto.<\/p>\n<p>Quando si parla di<strong> impianti per processi industriali,<\/strong> che assolutamente <strong>non devono mai fermarsi<\/strong> \u00e8 <strong>tassativo <\/strong>a mio parere <strong>scegliere la soluzione con macchine pi\u00f9 piccole in parallelo<\/strong>.<\/p>\n<p>I clienti di questi impianti, solitamente si assicurano con scelte che prevedono gi\u00e0 in partenza una <strong>ridondanza <\/strong>di sicurezza, ma anche in queto caso una scelta piutosto che un&#8217;altra, hanno dei risvolti che meritano di essere analizzati.<\/p>\n<p><a title=\"serbatoi chiller\" href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/serbatoi-chiller-1.JPG\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/serbatoi-chiller-1.thumbnail.JPG\" alt=\"serbatoi chiller\" \/><\/a><\/p>\n<p>Facciamo un caso specifico:<\/p>\n<ul>\n<li><strong>problema<\/strong>: impianto di processo che deve smaltire 1000 KW di potenza termica.<\/li>\n<li><strong>schema termico del servizio di raffreddamento<\/strong>: acqua a 18\u00b0C con salto termico di 10\u00b0C<\/li>\n<li><strong>zona di installazione<\/strong>: nord Italia, temperatura ambiente di progetto estiva 35\u00b0C, temperatura ambiente invernale 0+5\u00b0C<\/li>\n<li><strong>soluzione<\/strong>:  gruppo frigorifero condensato ad aria, asservito da sistema di free cooling, con relativo serbatoio di accumulo e gruppi di pompaggio.<\/li>\n<\/ul>\n<p><!--more--><a title=\"Chiller refrigeratori 3\" href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/verniciatura_03.jpg\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/verniciatura_03.thumbnail.jpg\" alt=\"Chiller refrigeratori 3\" \/><\/a><br \/>\n<em> Le temperature<\/em> non permettono di utilizzare torri di raffreddamento, quindi per f<em>orza di cose bisogna andare su dei refrigeratori<\/em>. Vista la <em>latitudine<\/em>, risulta di <em>interesse economico<\/em>, l&#8217;implementazione di un sistema di <em>free cooling<\/em>, per consentire un <strong>notevole risparmio energetico durante la stagione fredda<\/strong> e comunque poter parzializzare l&#8217;uso del chiller nella media stagione.<\/p>\n<p><a title=\"chiller free cooler 1\" href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/freecooling_chillers.jpg\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/freecooling_chillers.thumbnail.jpg\" alt=\"chiller free cooler 1\" \/><\/a><\/p>\n<p>Dal punto di vista del gruppo frigorifero, la cosa si pu\u00f2 risolvere facilmente con <strong>un chiller da 1000 KW termici<\/strong>, condensato ad aria, con compressore a vite o centrifugo.<\/p>\n<p><em>Soluzione semplice, ma senza scampo<\/em>, <strong>in caso malaugurato di avaria, tutto l&#8217;impianto \u00e8 fermo<\/strong>.<\/p>\n<p>Certamente si pu\u00f2 suggerire al cliente di installare <em>due gruppi, di cui uno in stand by al 100%<\/em>&#8230;<em>in pratica suggeriamo al cliente di raddoppiare <\/em><em>l&#8217;investimento<\/em> (o quasi).<\/p>\n<p><strong>Come dicevo sopra, la soluzione ideale \u00e8 quella di due gruppi frigoriferi di met\u00e0 potenza (500KW) , magari multicompressore<\/strong>.<\/p>\n<p><em>L&#8217;obiezione spontanea \u00e8 quella che comunque non c&#8217;\u00e8 uno &#8220;spare&#8221;.<\/em><\/p>\n<p><a title=\"Chiller refrigeratori 1\" href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/dscf0163.JPG\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/dscf0163.thumbnail.JPG\" alt=\"Chiller refrigeratori 1\" \/><\/a><\/p>\n<p>La soluzione \u00e8 quella di installare <strong>due gruppi frigoriferi a 4 circuiti cadauno<\/strong>,  di <em><strong>potenzialit\u00e0 leggermente superiore, magari 600 KW<\/strong><\/em> cadauno, in questo modo, <strong><em>anche in caso di avaria di uno degli otto<\/em><\/strong><\/p>\n<p><strong><em> compressori<\/em><\/strong>, il cliente ha comunque la <em><strong>piena potenza richiesta in fase di progetto<\/strong><\/em>.<\/p>\n<p><em>Certamente dei gruppi frigoriferi di questo tipo sono pi\u00f9 cari rispetto a gruppi monocompressore<\/em>, <strong>ma consentono di godere dei seguenti innegabili vantaggi:<\/strong><\/p>\n<ol>\n<li><strong>maggiore flessibilit\u00e0<\/strong><\/li>\n<li><strong>manutenzione specializzata, ma sicuramente pi\u00f9 alla portata del semplice frigorista, che magari gi\u00e0 bazzica gli impianti in azienda.<\/strong><\/li>\n<li><strong>in ottica del lungo periodo minori consumi energetici (quando si parzializza i compressori si spengono totalmente) <\/strong><\/li>\n<\/ol>\n<p>Allo stesso modo possiamo ragionare con le torri evaporative, con i radiatori (la nostra linea TCFC \u00e8 sviluppata proprio in maniera modulare sul numero dei ventilatori), sugli scambiatori di calore a piastre, sulle pompe dei gruppi di pompaggio, ecc&#8230;<\/p>\n<p>E&#8217; evidente che a volte ci sono limiti che vanno valutati, inoltre soluzioni di questo genere, non sono chiaramente applicabili ad impianti di piccola potenzialit\u00e0, dove per\u00f2 anche le criticit\u00e0 di fermi macchina, sono meno stringenti, e comunque il raddoppio di investimento in caso di necessit\u00e0 di ridondanza,  risulta meno oneroso.<\/p>\n<p><a title=\"Chiller refrigeratori 4\" href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/dscf0696.JPG\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/dscf0696.thumbnail.JPG\" alt=\"Chiller refrigeratori 4\" \/><\/a><a title=\"Chiller refrigeratori 6\" href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/lca_03.jpg\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/lca_03.thumbnail.jpg\" alt=\"Chiller refrigeratori 6\" \/><\/a><a title=\"Chiller refrigeratori scambiatore 1\" href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/nuovacoroxal_1.jpg\"><img decoding=\"async\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/nuovacoroxal_1.thumbnail.jpg\" alt=\"Chiller refrigeratori scambiatore 1\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Meglio uno grande o due (tre, quattro&#8230;), pi\u00f9 piccoli? Mi riferisco ovviamente alle macchine frigorifere che raffreddano un processo industriale. [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,6,12,9,7],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Meglio un refrigeratore grande o due (tre, quattro...), pi\u00f9 piccoli? - Tempco Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Meglio un refrigeratore grande o due (tre, quattro...), pi\u00f9 piccoli? - Tempco Blog\" \/>\n<meta property=\"og:description\" content=\"Meglio uno grande o due (tre, quattro&#8230;), pi\u00f9 piccoli? Mi riferisco ovviamente alle macchine frigorifere che raffreddano un processo industriale. [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/\" \/>\n<meta property=\"og:site_name\" content=\"Tempco Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tempco.srl\" \/>\n<meta property=\"article:published_time\" content=\"2007-11-22T09:04:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2011-03-03T13:54:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/dscf0758.thumbnail.JPG\" \/>\n<meta name=\"author\" content=\"Valter Biolchi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:site\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Valter Biolchi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/\"},\"author\":{\"name\":\"Valter Biolchi\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1\"},\"headline\":\"Meglio un refrigeratore grande o due (tre, quattro&#8230;), pi\u00f9 piccoli?\",\"datePublished\":\"2007-11-22T09:04:41+00:00\",\"dateModified\":\"2011-03-03T13:54:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/\"},\"wordCount\":538,\"commentCount\":2,\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"articleSection\":[\"Energia Termica\",\"Free cooling\",\"Refrigeratori\",\"Scambiatori di calore\",\"Torri Evaporative\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/\",\"name\":\"Meglio un refrigeratore grande o due (tre, quattro...), pi\u00f9 piccoli? - Tempco Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\"},\"datePublished\":\"2007-11-22T09:04:41+00:00\",\"dateModified\":\"2011-03-03T13:54:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tempco.it\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Meglio un refrigeratore grande o due (tre, quattro&#8230;), pi\u00f9 piccoli?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"name\":\"Tempco Blog\",\"description\":\"Soluzioni per l&#039;energia termica\",\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tempco.it\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\",\"name\":\"Tempco Srl\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"contentUrl\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"width\":317,\"height\":317,\"caption\":\"Tempco Srl\"},\"image\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tempco.srl\",\"https:\/\/twitter.com\/Tempco_it\",\"https:\/\/www.youtube.com\/c\/TempcoItalia\",\"https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/\",\"https:\/\/www.instagram.com\/tempco_solidtemperature\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1\",\"name\":\"Valter Biolchi\",\"sameAs\":[\"http:\/\/www.tempco.it\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Meglio un refrigeratore grande o due (tre, quattro...), pi\u00f9 piccoli? - Tempco Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/","og_locale":"it_IT","og_type":"article","og_title":"Meglio un refrigeratore grande o due (tre, quattro...), pi\u00f9 piccoli? - Tempco Blog","og_description":"Meglio uno grande o due (tre, quattro&#8230;), pi\u00f9 piccoli? Mi riferisco ovviamente alle macchine frigorifere che raffreddano un processo industriale. [&hellip;]","og_url":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/","og_site_name":"Tempco Blog","article_publisher":"https:\/\/www.facebook.com\/tempco.srl","article_published_time":"2007-11-22T09:04:41+00:00","article_modified_time":"2011-03-03T13:54:38+00:00","og_image":[{"url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2007\/11\/dscf0758.thumbnail.JPG"}],"author":"Valter Biolchi","twitter_card":"summary_large_image","twitter_creator":"@Tempco_it","twitter_site":"@Tempco_it","twitter_misc":{"Scritto da":"Valter Biolchi","Tempo di lettura stimato":"3 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/#article","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/"},"author":{"name":"Valter Biolchi","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1"},"headline":"Meglio un refrigeratore grande o due (tre, quattro&#8230;), pi\u00f9 piccoli?","datePublished":"2007-11-22T09:04:41+00:00","dateModified":"2011-03-03T13:54:38+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/"},"wordCount":538,"commentCount":2,"publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"articleSection":["Energia Termica","Free cooling","Refrigeratori","Scambiatori di calore","Torri Evaporative"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/","url":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/","name":"Meglio un refrigeratore grande o due (tre, quattro...), pi\u00f9 piccoli? - Tempco Blog","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/#website"},"datePublished":"2007-11-22T09:04:41+00:00","dateModified":"2011-03-03T13:54:38+00:00","breadcrumb":{"@id":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.tempco.it\/blog\/135\/chiller-grande-piccolo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tempco.it\/blog\/"},{"@type":"ListItem","position":2,"name":"Meglio un refrigeratore grande o due (tre, quattro&#8230;), pi\u00f9 piccoli?"}]},{"@type":"WebSite","@id":"https:\/\/www.tempco.it\/blog\/#website","url":"https:\/\/www.tempco.it\/blog\/","name":"Tempco Blog","description":"Soluzioni per l&#039;energia termica","publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tempco.it\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/www.tempco.it\/blog\/#organization","name":"Tempco Srl","url":"https:\/\/www.tempco.it\/blog\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","contentUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","width":317,"height":317,"caption":"Tempco Srl"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tempco.srl","https:\/\/twitter.com\/Tempco_it","https:\/\/www.youtube.com\/c\/TempcoItalia","https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/","https:\/\/www.instagram.com\/tempco_solidtemperature\/"]},{"@type":"Person","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1","name":"Valter Biolchi","sameAs":["http:\/\/www.tempco.it"]}]}},"_links":{"self":[{"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/posts\/135"}],"collection":[{"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/comments?post=135"}],"version-history":[{"count":3,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/posts\/135\/revisions"}],"predecessor-version":[{"id":2929,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/posts\/135\/revisions\/2929"}],"wp:attachment":[{"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/media?parent=135"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/categories?post=135"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/wp-json\/wp\/v2\/tags?post=135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}