{"id":9511,"date":"2023-07-28T11:23:41","date_gmt":"2023-07-28T09:23:41","guid":{"rendered":"https:\/\/www.tempco.it\/blog\/?p=9511"},"modified":"2023-07-28T14:55:55","modified_gmt":"2023-07-28T12:55:55","slug":"fouling-factor-each-type-of-exchanger-has-his-own","status":"publish","type":"post","link":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/","title":{"rendered":"Fouling factor, each type of exchanger has its own"},"content":{"rendered":"<p>The <a href=\"https:\/\/www.tempco.it\/blog\/en\/7002\/fouling-factor-in-heat-exchangers\/\"><strong>Fouling Factor<\/strong><\/a> is a subject that periodically comes back into the spotlight, a subject that we\u2019ve indeed already treated in other videos in our <a href=\"https:\/\/www.youtube.com\/@TempcoItalia\" target=\"_blank\" rel=\"noopener\">Tempco YouTube channel<\/a> and from the pages of this blog. Fouling Factor in <a href=\"https:\/\/en.tempco.it\/solutions-en\/heat-exchangers\/\" target=\"_blank\" rel=\"noopener\"><strong>plate heat exchangers<\/strong><\/a> is in fact a crucial element to determine the sizing of the exchanger upon the conditions of a certain application.<\/p>\n<p>The occasion to go back on it was given by a recent experience for an application made for a customer, who requested a fouling factor with a value usually related to <a href=\"https:\/\/en.tempco.it\/solutions-en\/heat-exchangers\/shell-and-tube-heat-exchangers\/\" target=\"_blank\" rel=\"noopener\">shell and tube exchangers<\/a>. The results were utterly deadly, because sizing the exchanger using fouling factor values suitable for a shell and tube exchanger led to a <strong>slowdown of the speeds of fluids<\/strong> inside the exchanger and therefore to an increase of the fouling, drastically <strong>reducing the efficiency of the thermal transfer rate<\/strong>.<\/p>\n<p>The solution to the problem has been to <strong>remove 30% of the plates from the exchanger<\/strong>, getting back to a fouling factor value more suitable for a plate heat exchanger.<\/p>\n<p><iframe loading=\"lazy\" title=\"FOULING DUE THE REVENGE\" width=\"750\" height=\"422\" src=\"https:\/\/www.youtube.com\/embed\/Q3aw0RabfYQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe><\/p>\n<p>Stay updated on the latest <strong>applications of thermal energy management<\/strong> by subscribing our monthly <strong><a href=\"https:\/\/en.tempco.it\/newsletter-solid-temperature\/\" target=\"_blank\" rel=\"noopener\">Tempco Newsletter &#8211; Solid Temperature<\/a><\/strong>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Fouling Factor is a crucial element to evaluate for the sizing of plate heat exchangers upon the conditions of a certain thermal application, in order to ensure the best flow rate of the fluids inside the exchangers and maximizing the thermal transfer efficiency. <\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[470,63,66,113,473],"tags":[486,495,1534,3825,483,138,123,129,3456,1543,125],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Fouling factor, each type of exchanger has its own - Tempco Blog<\/title>\n<meta name=\"description\" content=\"Fouling Factor is a crucial element to evaluate for the sizing of plate heat exchangers upon the conditions of a certain thermal application.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fouling factor, each type of exchanger has its own - Tempco Blog\" \/>\n<meta property=\"og:description\" content=\"Fouling Factor is a crucial element to evaluate for the sizing of plate heat exchangers upon the conditions of a certain thermal application.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/\" \/>\n<meta property=\"og:site_name\" content=\"Tempco Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tempco.srl\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-28T09:23:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-28T12:55:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"317\" \/>\n\t<meta property=\"og:image:height\" content=\"317\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Marco Zambelli\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:site\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marco Zambelli\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/\"},\"author\":{\"name\":\"Marco Zambelli\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec\"},\"headline\":\"Fouling factor, each type of exchanger has its own\",\"datePublished\":\"2023-07-28T09:23:41+00:00\",\"dateModified\":\"2023-07-28T12:55:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/\"},\"wordCount\":209,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"keywords\":[\"efficiency\",\"exchangers\",\"flow rate\",\"fluid's speed\",\"fouling factor\",\"heat exchangers\",\"plate heat exchangers\",\"shell and tube\",\"sizing\",\"solid temperature\",\"thermal transfer\"],\"articleSection\":[\"Fouling factor\",\"Heat exchangers\",\"Heating\",\"plate heat exchanger\",\"Scambiatori a piastre\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/\",\"name\":\"Fouling factor, each type of exchanger has its own - Tempco Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\"},\"datePublished\":\"2023-07-28T09:23:41+00:00\",\"dateModified\":\"2023-07-28T12:55:55+00:00\",\"description\":\"Fouling Factor is a crucial element to evaluate for the sizing of plate heat exchangers upon the conditions of a certain thermal application.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tempco.it\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fouling factor, each type of exchanger has its own\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"name\":\"Tempco Blog\",\"description\":\"Solutions for the thermal energy\",\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tempco.it\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\",\"name\":\"Tempco Srl\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"contentUrl\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"width\":317,\"height\":317,\"caption\":\"Tempco Srl\"},\"image\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tempco.srl\",\"https:\/\/twitter.com\/Tempco_it\",\"https:\/\/www.youtube.com\/c\/TempcoItalia\",\"https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/\",\"https:\/\/www.instagram.com\/tempco_solidtemperature\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec\",\"name\":\"Marco Zambelli\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fouling factor, each type of exchanger has its own - Tempco Blog","description":"Fouling Factor is a crucial element to evaluate for the sizing of plate heat exchangers upon the conditions of a certain thermal application.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/","og_locale":"en_US","og_type":"article","og_title":"Fouling factor, each type of exchanger has its own - Tempco Blog","og_description":"Fouling Factor is a crucial element to evaluate for the sizing of plate heat exchangers upon the conditions of a certain thermal application.","og_url":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/","og_site_name":"Tempco Blog","article_publisher":"https:\/\/www.facebook.com\/tempco.srl","article_published_time":"2023-07-28T09:23:41+00:00","article_modified_time":"2023-07-28T12:55:55+00:00","og_image":[{"width":317,"height":317,"url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","type":"image\/jpeg"}],"author":"Marco Zambelli","twitter_card":"summary_large_image","twitter_creator":"@Tempco_it","twitter_site":"@Tempco_it","twitter_misc":{"Written by":"Marco Zambelli","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/#article","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/"},"author":{"name":"Marco Zambelli","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec"},"headline":"Fouling factor, each type of exchanger has its own","datePublished":"2023-07-28T09:23:41+00:00","dateModified":"2023-07-28T12:55:55+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/"},"wordCount":209,"commentCount":0,"publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"keywords":["efficiency","exchangers","flow rate","fluid's speed","fouling factor","heat exchangers","plate heat exchangers","shell and tube","sizing","solid temperature","thermal transfer"],"articleSection":["Fouling factor","Heat exchangers","Heating","plate heat exchanger","Scambiatori a piastre"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/","url":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/","name":"Fouling factor, each type of exchanger has its own - Tempco Blog","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/#website"},"datePublished":"2023-07-28T09:23:41+00:00","dateModified":"2023-07-28T12:55:55+00:00","description":"Fouling Factor is a crucial element to evaluate for the sizing of plate heat exchangers upon the conditions of a certain thermal application.","breadcrumb":{"@id":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.tempco.it\/blog\/en\/9511\/fouling-factor-each-type-of-exchanger-has-his-own\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tempco.it\/blog\/"},{"@type":"ListItem","position":2,"name":"Fouling factor, each type of exchanger has its own"}]},{"@type":"WebSite","@id":"https:\/\/www.tempco.it\/blog\/#website","url":"https:\/\/www.tempco.it\/blog\/","name":"Tempco Blog","description":"Solutions for the thermal energy","publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tempco.it\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tempco.it\/blog\/#organization","name":"Tempco Srl","url":"https:\/\/www.tempco.it\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","contentUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","width":317,"height":317,"caption":"Tempco Srl"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tempco.srl","https:\/\/twitter.com\/Tempco_it","https:\/\/www.youtube.com\/c\/TempcoItalia","https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/","https:\/\/www.instagram.com\/tempco_solidtemperature\/"]},{"@type":"Person","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec","name":"Marco Zambelli"}]}},"_links":{"self":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/9511"}],"collection":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/comments?post=9511"}],"version-history":[{"count":2,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/9511\/revisions"}],"predecessor-version":[{"id":9513,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/9511\/revisions\/9513"}],"wp:attachment":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/media?parent=9511"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/categories?post=9511"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/tags?post=9511"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}