{"id":7858,"date":"2020-11-13T12:21:51","date_gmt":"2020-11-13T11:21:51","guid":{"rendered":"https:\/\/www.tempco.it\/blog\/?p=7858"},"modified":"2020-11-13T12:21:51","modified_gmt":"2020-11-13T11:21:51","slug":"cooling-towers-in-high-power-converter-testing","status":"publish","type":"post","link":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/","title":{"rendered":"Cooling towers in high power converter testing"},"content":{"rendered":"<p>Pictured here is a cooling system we deployed for a <strong>testing chamber for power converters<\/strong> we\u2019ve just supplied to a customer. The company is a manufacturer of IGBT, thyristors and diode type <strong>high power converters<\/strong>, that employ advanced electronics and digital regulation solutions.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-7849\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Torre-evaporativa-test-convertitori.jpg\" alt=\"Torre evaporativa test convertitori\" width=\"650\" height=\"641\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Torre-evaporativa-test-convertitori.jpg 850w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Torre-evaporativa-test-convertitori-300x296.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Torre-evaporativa-test-convertitori-768x758.jpg 768w\" sizes=\"(max-width: 650px) 100vw, 650px\" \/><\/p>\n<p>The dissipation system dedicated to the testing of power converters we have supplied is a prefabricated skid package solution, that includes:<\/p>\n<p>&#8211; <a href=\"https:\/\/en.tempco.it\/solutions-en\/cooling-towers\/\" target=\"_blank\" rel=\"noopener\"><strong>Evaporative tower<\/strong><\/a><br \/>\n&#8211; Pumping group<br \/>\n&#8211; <a href=\"https:\/\/en.tempco.it\/solutions-en\/heat-exchangers\/\" target=\"_blank\" rel=\"noopener\"><strong>Plate heat exchanger<\/strong><\/a><br \/>\n&#8211; <a href=\"https:\/\/en.tempco.it\/assistance\/water-treatment\/\" target=\"_blank\" rel=\"noopener\">Water softening and dosing system<\/a><br \/>\n&#8211; Electrical control cabinet with <strong>inverter<\/strong> on tower fans<\/p>\n<p>In particular, in inverter allows to adjust the speed of fans based on external ambient air temperatures, ensuring the maximum cooling efficiency with the lowest power consumption possible.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-7851\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Scambiatore-test-power-converters.jpg\" alt=\"Scambiatore test power converters\" width=\"650\" height=\"867\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Scambiatore-test-power-converters.jpg 680w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Scambiatore-test-power-converters-225x300.jpg 225w\" sizes=\"(max-width: 650px) 100vw, 650px\" \/><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-7853\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Tempco-scambiatori-test-convertitori.jpg\" alt=\"Tempco scambiatori test convertitori\" width=\"650\" height=\"867\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Tempco-scambiatori-test-convertitori.jpg 680w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Tempco-scambiatori-test-convertitori-225x300.jpg 225w\" sizes=\"(max-width: 650px) 100vw, 650px\" \/><\/p>\n<p>The <strong>cooling in test operations for power equipments<\/strong> is a very well consolidated field of application for Tempco, thanks to the expertise and know-how built in several projects developed. Not too long ago, we\u2019ve indeed already talked about a quite identical application for <a href=\"https:\/\/www.tempco.it\/blog\/en\/7130\/free-cooling-for-heat-dissipation-in-inverter-testing\/\" target=\"_blank\" rel=\"noopener\">heat dissipation in the testing of inverters<\/a>, made with a <a href=\"https:\/\/en.tempco.it\/solutions-en\/industrial-coolers-electroradiators\/\" target=\"_blank\" rel=\"noopener\"><strong>dry-cooler<\/strong><\/a> for lower power capacities.<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-7855\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Tempco-test-convertitori.jpg\" alt=\"Tempco test convertitori\" width=\"651\" height=\"488\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Tempco-test-convertitori.jpg 907w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Tempco-test-convertitori-300x225.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Tempco-test-convertitori-768x576.jpg 768w\" sizes=\"(max-width: 651px) 100vw, 651px\" \/><\/p>\n<p>Subscribe here to our <strong><a href=\"https:\/\/en.tempco.it\/newsletter-solid-temperature\/\" target=\"_blank\" rel=\"noopener\">Tempco Newsletter &#8211; Solid Temperature<\/a><\/strong>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Cooling tower for heat dissipation in testing of high power converters, the inverter on fans allows smart adjustment of power consumption required for ventilation. <\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[64,65,63,113],"tags":[127,178,258,74,430,138,71,123,2087,1101,2592,2591,1543,1098,1374],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Cooling towers in high power converter testing - Tempco Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cooling towers in high power converter testing - Tempco Blog\" \/>\n<meta property=\"og:description\" content=\"Cooling tower for heat dissipation in testing of high power converters, the inverter on fans allows smart adjustment of power consumption required for ventilation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"Tempco Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tempco.srl\" \/>\n<meta property=\"article:published_time\" content=\"2020-11-13T11:21:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Torre-evaporativa-test-convertitori.jpg\" \/>\n<meta name=\"author\" content=\"Marco Zambelli\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:site\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marco Zambelli\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/\"},\"author\":{\"name\":\"Marco Zambelli\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec\"},\"headline\":\"Cooling towers in high power converter testing\",\"datePublished\":\"2020-11-13T11:21:51+00:00\",\"dateModified\":\"2020-11-13T11:21:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/\"},\"wordCount\":194,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"keywords\":[\"cooling\",\"cooling tower\",\"dry cooler\",\"energy saving\",\"evaporative towers\",\"heat exchangers\",\"inverter\",\"plate heat exchangers\",\"power consumption\",\"power converters\",\"power equipment\",\"pumping circuit\",\"solid temperature\",\"testing\",\"water treatment\"],\"articleSection\":[\"Cooling\",\"Evaporative Towers\",\"Heat exchangers\",\"plate heat exchanger\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/\",\"name\":\"Cooling towers in high power converter testing - Tempco Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\"},\"datePublished\":\"2020-11-13T11:21:51+00:00\",\"dateModified\":\"2020-11-13T11:21:51+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tempco.it\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cooling towers in high power converter testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"name\":\"Tempco Blog\",\"description\":\"Solutions for the thermal energy\",\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tempco.it\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\",\"name\":\"Tempco Srl\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"contentUrl\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"width\":317,\"height\":317,\"caption\":\"Tempco Srl\"},\"image\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tempco.srl\",\"https:\/\/twitter.com\/Tempco_it\",\"https:\/\/www.youtube.com\/c\/TempcoItalia\",\"https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/\",\"https:\/\/www.instagram.com\/tempco_solidtemperature\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec\",\"name\":\"Marco Zambelli\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cooling towers in high power converter testing - Tempco Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/","og_locale":"en_US","og_type":"article","og_title":"Cooling towers in high power converter testing - Tempco Blog","og_description":"Cooling tower for heat dissipation in testing of high power converters, the inverter on fans allows smart adjustment of power consumption required for ventilation.","og_url":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/","og_site_name":"Tempco Blog","article_publisher":"https:\/\/www.facebook.com\/tempco.srl","article_published_time":"2020-11-13T11:21:51+00:00","og_image":[{"url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2020\/11\/Torre-evaporativa-test-convertitori.jpg"}],"author":"Marco Zambelli","twitter_card":"summary_large_image","twitter_creator":"@Tempco_it","twitter_site":"@Tempco_it","twitter_misc":{"Written by":"Marco Zambelli","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/#article","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/"},"author":{"name":"Marco Zambelli","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec"},"headline":"Cooling towers in high power converter testing","datePublished":"2020-11-13T11:21:51+00:00","dateModified":"2020-11-13T11:21:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/"},"wordCount":194,"commentCount":0,"publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"keywords":["cooling","cooling tower","dry cooler","energy saving","evaporative towers","heat exchangers","inverter","plate heat exchangers","power consumption","power converters","power equipment","pumping circuit","solid temperature","testing","water treatment"],"articleSection":["Cooling","Evaporative Towers","Heat exchangers","plate heat exchanger"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/","url":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/","name":"Cooling towers in high power converter testing - Tempco Blog","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/#website"},"datePublished":"2020-11-13T11:21:51+00:00","dateModified":"2020-11-13T11:21:51+00:00","breadcrumb":{"@id":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.tempco.it\/blog\/en\/7858\/cooling-towers-in-high-power-converter-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tempco.it\/blog\/"},{"@type":"ListItem","position":2,"name":"Cooling towers in high power converter testing"}]},{"@type":"WebSite","@id":"https:\/\/www.tempco.it\/blog\/#website","url":"https:\/\/www.tempco.it\/blog\/","name":"Tempco Blog","description":"Solutions for the thermal energy","publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tempco.it\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tempco.it\/blog\/#organization","name":"Tempco Srl","url":"https:\/\/www.tempco.it\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","contentUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","width":317,"height":317,"caption":"Tempco Srl"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tempco.srl","https:\/\/twitter.com\/Tempco_it","https:\/\/www.youtube.com\/c\/TempcoItalia","https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/","https:\/\/www.instagram.com\/tempco_solidtemperature\/"]},{"@type":"Person","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec","name":"Marco Zambelli"}]}},"_links":{"self":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/7858"}],"collection":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/comments?post=7858"}],"version-history":[{"count":1,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/7858\/revisions"}],"predecessor-version":[{"id":7859,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/7858\/revisions\/7859"}],"wp:attachment":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/media?parent=7858"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/categories?post=7858"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/tags?post=7858"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}