{"id":6803,"date":"2019-02-22T14:51:36","date_gmt":"2019-02-22T13:51:36","guid":{"rendered":"http:\/\/www.tempco.it\/blog\/?p=6803"},"modified":"2019-02-26T17:20:07","modified_gmt":"2019-02-26T16:20:07","slug":"mechanical-seal-troubleshooting-part-2","status":"publish","type":"post","link":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/","title":{"rendered":"Mechanical seal troubleshooting part 2"},"content":{"rendered":"<p>Chapter two on the topic of how to detect and recognize the causes of <strong>mechanical seal troubles<\/strong>, after the post dedicated to the <a href=\"https:\/\/www.tempco.it\/blog\/en\/6751\/mechanical-seal-troubleshooting\/\" target=\"_blank\" rel=\"noopener\">problems related to lubrication<\/a>. Mechanical seals can undergo a series of different kind of <strong>wear<\/strong>. An irregular wear can be the consequence of an excessive wear on bearings and in <strong>presence of vibrations<\/strong>.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-troubleshooting.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-6780\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-troubleshooting-1024x834.jpg\" alt=\"usura tenute meccaniche\" width=\"375\" height=\"305\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-troubleshooting-1024x834.jpg 1024w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-troubleshooting-300x244.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-troubleshooting-768x625.jpg 768w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-troubleshooting.jpg 1727w\" sizes=\"(max-width: 375px) 100vw, 375px\" \/><\/a><\/p>\n<p>Small amounts of tough particles in the fluids can also lead to <strong>corrosion on mechanical seals<\/strong>: by sedimenting on the seal&#8217;s surface, these particles act like cutting tools in a grinding machine, damaging contact surfaces. An <strong>intermittent spotted wear<\/strong> on the seal surface can also relate to an imperfect linearity of the seal surface itself, due to defective mechanical construction of the seal, or even due to a <strong>wrong mounting<\/strong>.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter  wp-image-6785\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche.jpg\" alt=\"usura faccia tenute meccaniche\" width=\"389\" height=\"305\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche.jpg 861w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-300x235.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-768x601.jpg 768w\" sizes=\"(max-width: 389px) 100vw, 389px\" \/><\/a><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-faccia-di-tenuta-1.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter  wp-image-6787\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-faccia-di-tenuta-1-1024x526.jpg\" alt=\"usura intermittente facce di tenuta\" width=\"498\" height=\"256\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-faccia-di-tenuta-1-1024x526.jpg 1024w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-faccia-di-tenuta-1-300x154.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-faccia-di-tenuta-1-768x394.jpg 768w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-faccia-di-tenuta-1.jpg 1083w\" sizes=\"(max-width: 498px) 100vw, 498px\" \/><\/a><\/p>\n<p><em><strong>Mismatched materials and fluids<\/strong><\/em><br \/>\nThe right <strong>choice of seal\u2019s materials<\/strong> is essential to ensure a long mechanical seal working lifetime, enabled by the compatibility between the seal\u2019s material and the pumped fluids. A wrong matching can lead to <strong>swelling problems in elastomers<\/strong>, boosted by the high temperatures and the long exposure periods involved. <strong>Corrosion on mechanical seals<\/strong> can also be provoked by the incompatibility between materials and fluids, deteriorating the seal surfaces.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/swelling-tenute-meccaniche.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter  wp-image-6789\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/swelling-tenute-meccaniche-1024x504.jpg\" alt=\"swelling elastomeri\" width=\"500\" height=\"246\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/swelling-tenute-meccaniche-1024x504.jpg 1024w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/swelling-tenute-meccaniche-300x148.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/swelling-tenute-meccaniche-768x378.jpg 768w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/swelling-tenute-meccaniche.jpg 1229w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/corrosione-tenute-meccaniche.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter  wp-image-6791\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/corrosione-tenute-meccaniche-1024x503.jpg\" alt=\"corrosione tenute meccaniche\" width=\"501\" height=\"246\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/corrosione-tenute-meccaniche-1024x503.jpg 1024w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/corrosione-tenute-meccaniche-300x147.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/corrosione-tenute-meccaniche-768x378.jpg 768w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/corrosione-tenute-meccaniche.jpg 1255w\" sizes=\"(max-width: 501px) 100vw, 501px\" \/><\/a><\/p>\n<p><em><strong>Installation and connections<\/strong><\/em><br \/>\nThe correct installation is also a key factor to preserve the conditions of a mechanical seal. Pictured here are two examples of damages related to a <strong>wrong installation of the seal<\/strong>, leading to <strong>cut or damaged OR<\/strong> and <strong>breakage of the seal ring<\/strong>.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-OR-danneggiati.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter  wp-image-6793\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-OR-danneggiati.jpg\" alt=\"OR danneggiati tenute meccaniche\" width=\"388\" height=\"306\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-OR-danneggiati.jpg 912w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-OR-danneggiati-300x237.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-OR-danneggiati-768x606.jpg 768w\" sizes=\"(max-width: 388px) 100vw, 388px\" \/><\/a><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/rottura-anello-di-tenuta.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter  wp-image-6795\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/rottura-anello-di-tenuta-1024x626.jpg\" alt=\"rottura anello di tenuta\" width=\"463\" height=\"283\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/rottura-anello-di-tenuta-1024x626.jpg 1024w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/rottura-anello-di-tenuta-300x183.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/rottura-anello-di-tenuta-768x469.jpg 768w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/rottura-anello-di-tenuta.jpg 1157w\" sizes=\"(max-width: 463px) 100vw, 463px\" \/><\/a><\/p>\n<p>Also the <strong>working pressure of the pump<\/strong> must be comprised in the range of design values of the mechanical seal. In case of <strong>excessive pressure<\/strong>, the seal can be damaged irreversibly. At last, pay attention to the <strong>rotation verse of the pump<\/strong>, to avoid a <strong>breakage of the spring<\/strong>. This breakages can happen with a wrong electrical connection of the engine, a pump installed in parallel without a check valve, or also with a return flow when the pump is off.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/pressione-elevata-rottura-tenute.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter  wp-image-6797\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/pressione-elevata-rottura-tenute-1024x529.jpg\" alt=\"danni da pressione tenute meccaniche\" width=\"491\" height=\"254\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/pressione-elevata-rottura-tenute-1024x529.jpg 1024w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/pressione-elevata-rottura-tenute-300x155.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/pressione-elevata-rottura-tenute-768x397.jpg 768w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/pressione-elevata-rottura-tenute.jpg 1179w\" sizes=\"(max-width: 491px) 100vw, 491px\" \/><\/a><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-molla-rotta.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter  wp-image-6799\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-molla-rotta.jpg\" alt=\"rottura molla tenute meccaniche\" width=\"417\" height=\"281\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-molla-rotta.jpg 844w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-molla-rotta-300x202.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/tenute-meccaniche-molla-rotta-768x518.jpg 768w\" sizes=\"(max-width: 417px) 100vw, 417px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>The <a href=\"https:\/\/en.tempco.it\/assistance\/\" target=\"_blank\" rel=\"noopener\"><strong>Tempco Service<\/strong><\/a> is at your disposal to solve any doubt or needs.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mechanical seal troubleshooting, wear, corrosion, breakages and deformation due to wrong installation or mismatching bewteen construction materials and pumped fluids. <\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[247,469,61,87,88,84],"tags":[1601,254,474,1600,800,1581,279,1599,1567,1563,1602,727,1604,356,1596,1569,1603,1576],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Mechanical seal troubleshooting part 2 - Tempco Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mechanical seal troubleshooting part 2 - Tempco Blog\" \/>\n<meta property=\"og:description\" content=\"Mechanical seal troubleshooting, wear, corrosion, breakages and deformation due to wrong installation or mismatching bewteen construction materials and pumped fluids.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Tempco Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tempco.srl\" \/>\n<meta property=\"article:published_time\" content=\"2019-02-22T13:51:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-02-26T16:20:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-troubleshooting-1024x834.jpg\" \/>\n<meta name=\"author\" content=\"Marco Zambelli\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:site\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marco Zambelli\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/\"},\"author\":{\"name\":\"Marco Zambelli\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec\"},\"headline\":\"Mechanical seal troubleshooting part 2\",\"datePublished\":\"2019-02-22T13:51:36+00:00\",\"dateModified\":\"2019-02-26T16:20:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/\"},\"wordCount\":345,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"keywords\":[\"breakage\",\"corrosion\",\"corrosione\",\"elastomers\",\"engines\",\"lubrication\",\"maintenance\",\"mechanical seals\",\"O-ring\",\"pressure\",\"problems resolution\",\"pumps\",\"seal ring\",\"service\",\"swelling\",\"troubleshooting\",\"vibrations\",\"wear\"],\"articleSection\":[\"corrosion\",\"Corrosione\",\"Energia Termica @en\",\"Maintenance\",\"Service\",\"thermal energy\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/\",\"name\":\"Mechanical seal troubleshooting part 2 - Tempco Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\"},\"datePublished\":\"2019-02-22T13:51:36+00:00\",\"dateModified\":\"2019-02-26T16:20:07+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tempco.it\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mechanical seal troubleshooting part 2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"name\":\"Tempco Blog\",\"description\":\"Solutions for the thermal energy\",\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tempco.it\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\",\"name\":\"Tempco Srl\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"contentUrl\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"width\":317,\"height\":317,\"caption\":\"Tempco Srl\"},\"image\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tempco.srl\",\"https:\/\/twitter.com\/Tempco_it\",\"https:\/\/www.youtube.com\/c\/TempcoItalia\",\"https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/\",\"https:\/\/www.instagram.com\/tempco_solidtemperature\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec\",\"name\":\"Marco Zambelli\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Mechanical seal troubleshooting part 2 - Tempco Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/","og_locale":"en_US","og_type":"article","og_title":"Mechanical seal troubleshooting part 2 - Tempco Blog","og_description":"Mechanical seal troubleshooting, wear, corrosion, breakages and deformation due to wrong installation or mismatching bewteen construction materials and pumped fluids.","og_url":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/","og_site_name":"Tempco Blog","article_publisher":"https:\/\/www.facebook.com\/tempco.srl","article_published_time":"2019-02-22T13:51:36+00:00","article_modified_time":"2019-02-26T16:20:07+00:00","og_image":[{"url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2019\/02\/usura-tenute-meccaniche-troubleshooting-1024x834.jpg"}],"author":"Marco Zambelli","twitter_card":"summary_large_image","twitter_creator":"@Tempco_it","twitter_site":"@Tempco_it","twitter_misc":{"Written by":"Marco Zambelli","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/#article","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/"},"author":{"name":"Marco Zambelli","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec"},"headline":"Mechanical seal troubleshooting part 2","datePublished":"2019-02-22T13:51:36+00:00","dateModified":"2019-02-26T16:20:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/"},"wordCount":345,"commentCount":0,"publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"keywords":["breakage","corrosion","corrosione","elastomers","engines","lubrication","maintenance","mechanical seals","O-ring","pressure","problems resolution","pumps","seal ring","service","swelling","troubleshooting","vibrations","wear"],"articleSection":["corrosion","Corrosione","Energia Termica @en","Maintenance","Service","thermal energy"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/","url":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/","name":"Mechanical seal troubleshooting part 2 - Tempco Blog","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/#website"},"datePublished":"2019-02-22T13:51:36+00:00","dateModified":"2019-02-26T16:20:07+00:00","breadcrumb":{"@id":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.tempco.it\/blog\/en\/6803\/mechanical-seal-troubleshooting-part-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tempco.it\/blog\/"},{"@type":"ListItem","position":2,"name":"Mechanical seal troubleshooting part 2"}]},{"@type":"WebSite","@id":"https:\/\/www.tempco.it\/blog\/#website","url":"https:\/\/www.tempco.it\/blog\/","name":"Tempco Blog","description":"Solutions for the thermal energy","publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tempco.it\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tempco.it\/blog\/#organization","name":"Tempco Srl","url":"https:\/\/www.tempco.it\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","contentUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","width":317,"height":317,"caption":"Tempco Srl"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tempco.srl","https:\/\/twitter.com\/Tempco_it","https:\/\/www.youtube.com\/c\/TempcoItalia","https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/","https:\/\/www.instagram.com\/tempco_solidtemperature\/"]},{"@type":"Person","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/888443da8bdce0582bcb917053553fec","name":"Marco Zambelli"}]}},"_links":{"self":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/6803"}],"collection":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/comments?post=6803"}],"version-history":[{"count":2,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/6803\/revisions"}],"predecessor-version":[{"id":6807,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/6803\/revisions\/6807"}],"wp:attachment":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/media?parent=6803"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/categories?post=6803"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/tags?post=6803"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}