{"id":6172,"date":"2018-01-25T14:15:31","date_gmt":"2018-01-25T13:15:31","guid":{"rendered":"https:\/\/www.tempco.it\/blog\/?p=6172\/"},"modified":"2018-01-25T11:18:27","modified_gmt":"2018-01-25T10:18:27","slug":"the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil","status":"publish","type":"post","link":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/","title":{"rendered":"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil"},"content":{"rendered":"<p>1. Check safety and control devices: for correct installation and functioning, be sure that the range settings are proper for the operation. Manually activate and test the instruments and apply all tests necessary to assure the right functioning.<br \/>\n2. Check for leakage.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2018\/01\/iStock-616899444.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-large wp-image-6169\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2018\/01\/iStock-616899444-1024x691.jpg\" alt=\"\" width=\"750\" height=\"506\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2018\/01\/iStock-616899444-1024x691.jpg 1024w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2018\/01\/iStock-616899444-300x202.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2018\/01\/iStock-616899444-768x518.jpg 768w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/a><\/p>\n<p>3. Remove moisture from the system, using dry compressed air or other suitable means.<br \/>\n4. Fill the system with heat transfer fluid.<br \/>\nFill the system with heat transfer fluid, with all vents to the expansion tank or atmosphere open for air removal. Fill the expansion tank to low level. Where needed (in low temperature environment), have the steam tracing system switched on.<br \/>\nOpen all valves, then start the main circulating pump in accordance with the manufacturer\u2019s recommendations. Observe the liquid level in the expansion tank, refilling as necessary until the system has been filled. The expansion tank should be adjusted to 70%\u201375% full when the hot operating temperature is reached.<br \/>\nSuggested start-up procedure for new systems circulate the heat transfer fluid through the system for about 4 hours to eliminate air pockets and to assure complete system fill. Before firing the heater, be sure that the heat transfer fluid is circulating freely through the entire system.<\/p>\n<p>5. Start the heater. Bring the system up to temperature very slowly\u2014about 35\u00b0C per hour. This should prevent thermal shock to heater tubes, tube\/heater joints, refractory materials, etc., and will allow operators to check the functioning of instruments and controls. The slow heat-up also will allow moisture trapped in all sections of the system to escape as a vapor.Hold the temperature above 100\u00b0C until no signs of moisture remain (e.g., knocking or rattling of pipes, moisture from vents, etc.).<\/p>\n","protected":false},"excerpt":{"rendered":"<p>1. Check safety and control devices: for correct installation and functioning, be sure that the range settings are proper for [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[63,66,710,84,76],"tags":[392,234,128],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil - Tempco Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil - Tempco Blog\" \/>\n<meta property=\"og:description\" content=\"1. Check safety and control devices: for correct installation and functioning, be sure that the range settings are proper for [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/\" \/>\n<meta property=\"og:site_name\" content=\"Tempco Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tempco.srl\" \/>\n<meta property=\"article:published_time\" content=\"2018-01-25T13:15:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2018-01-25T10:18:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2018\/01\/iStock-616899444-1024x691.jpg\" \/>\n<meta name=\"author\" content=\"Valter Biolchi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:site\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Valter Biolchi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/\"},\"author\":{\"name\":\"Valter Biolchi\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1\"},\"headline\":\"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil\",\"datePublished\":\"2018-01-25T13:15:31+00:00\",\"dateModified\":\"2018-01-25T10:18:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/\"},\"wordCount\":288,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"keywords\":[\"diathermic oil\",\"thermoregulating units\",\"thermoregulation\"],\"articleSection\":[\"Heat exchangers\",\"Heating\",\"temperature control unit\",\"thermal energy\",\"Thermoregulation Unit\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/\",\"name\":\"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil - Tempco Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\"},\"datePublished\":\"2018-01-25T13:15:31+00:00\",\"dateModified\":\"2018-01-25T10:18:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tempco.it\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"name\":\"Tempco Blog\",\"description\":\"Solutions for the thermal energy\",\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tempco.it\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\",\"name\":\"Tempco Srl\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"contentUrl\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"width\":317,\"height\":317,\"caption\":\"Tempco Srl\"},\"image\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tempco.srl\",\"https:\/\/twitter.com\/Tempco_it\",\"https:\/\/www.youtube.com\/c\/TempcoItalia\",\"https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/\",\"https:\/\/www.instagram.com\/tempco_solidtemperature\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1\",\"name\":\"Valter Biolchi\",\"sameAs\":[\"http:\/\/www.tempco.it\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil - Tempco Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/","og_locale":"en_US","og_type":"article","og_title":"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil - Tempco Blog","og_description":"1. Check safety and control devices: for correct installation and functioning, be sure that the range settings are proper for [&hellip;]","og_url":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/","og_site_name":"Tempco Blog","article_publisher":"https:\/\/www.facebook.com\/tempco.srl","article_published_time":"2018-01-25T13:15:31+00:00","article_modified_time":"2018-01-25T10:18:27+00:00","og_image":[{"url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2018\/01\/iStock-616899444-1024x691.jpg"}],"author":"Valter Biolchi","twitter_card":"summary_large_image","twitter_creator":"@Tempco_it","twitter_site":"@Tempco_it","twitter_misc":{"Written by":"Valter Biolchi","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/#article","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/"},"author":{"name":"Valter Biolchi","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1"},"headline":"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil","datePublished":"2018-01-25T13:15:31+00:00","dateModified":"2018-01-25T10:18:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/"},"wordCount":288,"commentCount":0,"publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"keywords":["diathermic oil","thermoregulating units","thermoregulation"],"articleSection":["Heat exchangers","Heating","temperature control unit","thermal energy","Thermoregulation Unit"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/","url":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/","name":"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil - Tempco Blog","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/#website"},"datePublished":"2018-01-25T13:15:31+00:00","dateModified":"2018-01-25T10:18:27+00:00","breadcrumb":{"@id":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.tempco.it\/blog\/en\/6172\/the-5-must-to-do-point-to-start-up-treg-hce-hcst-o-oh-diathermic-oil\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tempco.it\/blog\/"},{"@type":"ListItem","position":2,"name":"The 5 must to-do point to start-up TREG HCE\/HCST O\/OH diathermic oil"}]},{"@type":"WebSite","@id":"https:\/\/www.tempco.it\/blog\/#website","url":"https:\/\/www.tempco.it\/blog\/","name":"Tempco Blog","description":"Solutions for the thermal energy","publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tempco.it\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tempco.it\/blog\/#organization","name":"Tempco Srl","url":"https:\/\/www.tempco.it\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","contentUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","width":317,"height":317,"caption":"Tempco Srl"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tempco.srl","https:\/\/twitter.com\/Tempco_it","https:\/\/www.youtube.com\/c\/TempcoItalia","https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/","https:\/\/www.instagram.com\/tempco_solidtemperature\/"]},{"@type":"Person","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1","name":"Valter Biolchi","sameAs":["http:\/\/www.tempco.it"]}]}},"_links":{"self":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/6172"}],"collection":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/comments?post=6172"}],"version-history":[{"count":2,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/6172\/revisions"}],"predecessor-version":[{"id":6174,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/6172\/revisions\/6174"}],"wp:attachment":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/media?parent=6172"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/categories?post=6172"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/tags?post=6172"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}