{"id":4512,"date":"2013-11-25T10:13:06","date_gmt":"2013-11-25T08:13:06","guid":{"rendered":"https:\/\/www.tempco.it\/blog\/?p=4512"},"modified":"2023-03-16T13:06:22","modified_gmt":"2023-03-16T12:06:22","slug":"data-center-cooling-can-save-energy","status":"publish","type":"post","link":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/","title":{"rendered":"Data center cooling can save energy"},"content":{"rendered":"<p>Only a few years ago, data centres were synonymous with major\u00a0<a href=\"http:\/\/en.tempco.it\/solutions\/chillers\/\">HVAC plant installation<\/a>,\u00a0needed to keep computer rooms at low and controlled temperatures.<\/p>\n<p>Even today it is necessary to \u00a0<a href=\"http:\/\/en.tempco.it\/solutions\/industrial-coolers-electroradiators\/\"><strong>dissipate the heat generated<\/strong><\/a>\u00a0by hundreds or thousands of computers working tirelessly in a data centre &#8230; every time I enter the room where our small LAN server is housed, even with the heating turned off, even in winter, the air conditioning system is turned on.<\/p>\n<p>The great leap forward made in recent years, is linked to\u00a0<strong> working temperatures<\/strong>\u00a0 currently endured by these computers.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/iStock_000024498518Large.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/iStock_000024498518Large-300x153.jpg\" alt=\"Blue and red binary code floating in data center hall leading to light\" width=\"300\" height=\"153\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>Let me explain. Initially, to provide air conditioning to a computer room, cooling systems that provided chilled water at the classic temperature of 7\u00b0C, with a temperature difference of 5\u00b0C (the classic 7\/12\u00b0C) had to be installed<\/p>\n<p>Current systems require water for direct cooling at considerably higher temperatures around 15\/20\u00b0C and, as such, they are more efficient, needing to dissipate less thermal energy.<\/p>\n<p>If thermal energy savings are easily understood, 100 KW is less than 120 KW, it is however more complex to understand and, for technicians, it is linked to the temperature.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/iStock_000028754418Large.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/iStock_000028754418Large-300x199.jpg\" alt=\"iStock_000028754418Large\" width=\"300\" height=\"199\" \/><\/a><\/p>\n<p>In my ebook &#8220;<a href=\"http:\/\/www.lulu.com\/shop\/valter-biolchi\/energia-termica-e-processi-industriali\/paperback\/product-21138446.html\">Energia termica e processi industriali<\/a>&#8221; (at the moment only in italian language) i explain:<\/p>\n<p>chiller capacity increase and energy consumption decrease, if they produce chilled water at higher temperature, 15\u00b0C instead of 7\u00b0C.<\/p>\n<p>This is surely a very important aspect in managing data centres. This upward shift in temperature allows you to make assessments involving choices that are definitely more green and less energy intensive.<\/p>\n<p>As demonstrated by the choices made \u200b\u200bfor the latest data centre installations, these complexes tend to be built in areas that provide &#8220;water at naturally low temperatures&#8221;, fjords, rivers in cold areas, icy seas, mines or the like, or in areas with harsh climates, \u00a0so that so-called free cooling can be exploited.<\/p>\n<p>It is precisely these applications which are becoming the key to saving energy for data centres.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2012\/03\/IM0011301.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2012\/03\/IM0011301-300x225.jpg\" alt=\"Free cooling plant to cool down big data center\" width=\"300\" height=\"225\" \/><\/a><\/p>\n<p><a href=\"http:\/\/www.tempco.it\/soluzioni\/scambiatori-calore\/ispezionabili\/\">Plate heat exchangers TPLATE<\/a>,\u00a0<a href=\"http:\/\/www.tempco.it\/soluzioni\/raffreddatori-industriali-elettroradiatori\/t-fin-iq\/\">free coolers TFIN<\/a>\u00a0are the products that we have studied and are improving to meet these new and more interesting applications.<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/iStock_000017774404Medium.jpg\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/iStock_000017774404Medium-208x300.jpg\" alt=\"iStock_000017774404Medium\" width=\"208\" height=\"300\" \/><\/a><\/p>\n<p>\u00a0<a href=\"http:\/\/www.tempco.it\/soluzioni\/scambiatori-calore\/immersione\/\" class=\"broken_link\"><strong>Immersion heat exchangers TCOIL<\/strong><\/a>\u00a0represent the\u00a0<strong>new frontier in free cooling driven by data centres<\/strong>.<\/p>\n<p>A heat exchange system, which combines management costs reduced to a minimum, high quality with unparalleled constructive flexibility. All this combined with the zero cost for main pumping.<\/p>\n<p><a href=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/DSCF3362.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/DSCF3362-224x300.jpg\" alt=\"TCOIL heat exchanger energy saving\" width=\"224\" height=\"300\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><em>note:<\/em><\/p>\n<p><em>1. In essence, with the downward variance of the water temperature required, a cooling system sees its thermal efficiency reduce. Or, we can say that a cooling system that needs to dissipate a defined quantity of thermal energy, at a higher temperature, consumes less than another system that needs to dissipate the same amount of thermal energy but at a lower temperature.<\/em><\/p>\n<p><em>For example: 100,000 Kcal\/h of water at 5\u00b0C costs more than 100,000 Kcal\/h at 15\u00b0C.<\/em><\/p>\n<p><em>\u00a0<\/em><\/p>\n<p><em>2. A cooling system yields more under conditions of low environmental temperature (within certain limits), compared to an installation in a warmer environment.\u00a0<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Only a few years ago, data centres were synonymous with major\u00a0HVAC plant installation,\u00a0needed to keep computer rooms at low and [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[61],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Data center cooling can save energy - Tempco Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Data center cooling can save energy - Tempco Blog\" \/>\n<meta property=\"og:description\" content=\"Only a few years ago, data centres were synonymous with major\u00a0HVAC plant installation,\u00a0needed to keep computer rooms at low and [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/\" \/>\n<meta property=\"og:site_name\" content=\"Tempco Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tempco.srl\" \/>\n<meta property=\"article:published_time\" content=\"2013-11-25T08:13:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-16T12:06:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/iStock_000024498518Large-300x153.jpg\" \/>\n<meta name=\"author\" content=\"Valter Biolchi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:site\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Valter Biolchi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/\"},\"author\":{\"name\":\"Valter Biolchi\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1\"},\"headline\":\"Data center cooling can save energy\",\"datePublished\":\"2013-11-25T08:13:06+00:00\",\"dateModified\":\"2023-03-16T12:06:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/\"},\"wordCount\":496,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"articleSection\":[\"Energia Termica @en\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/\",\"name\":\"Data center cooling can save energy - Tempco Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\"},\"datePublished\":\"2013-11-25T08:13:06+00:00\",\"dateModified\":\"2023-03-16T12:06:22+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tempco.it\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Data center cooling can save energy\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#website\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"name\":\"Tempco Blog\",\"description\":\"Solutions for the thermal energy\",\"publisher\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tempco.it\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#organization\",\"name\":\"Tempco Srl\",\"url\":\"https:\/\/www.tempco.it\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"contentUrl\":\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg\",\"width\":317,\"height\":317,\"caption\":\"Tempco Srl\"},\"image\":{\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tempco.srl\",\"https:\/\/twitter.com\/Tempco_it\",\"https:\/\/www.youtube.com\/c\/TempcoItalia\",\"https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/\",\"https:\/\/www.instagram.com\/tempco_solidtemperature\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1\",\"name\":\"Valter Biolchi\",\"sameAs\":[\"http:\/\/www.tempco.it\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Data center cooling can save energy - Tempco Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/","og_locale":"en_US","og_type":"article","og_title":"Data center cooling can save energy - Tempco Blog","og_description":"Only a few years ago, data centres were synonymous with major\u00a0HVAC plant installation,\u00a0needed to keep computer rooms at low and [&hellip;]","og_url":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/","og_site_name":"Tempco Blog","article_publisher":"https:\/\/www.facebook.com\/tempco.srl","article_published_time":"2013-11-25T08:13:06+00:00","article_modified_time":"2023-03-16T12:06:22+00:00","og_image":[{"url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2013\/11\/iStock_000024498518Large-300x153.jpg"}],"author":"Valter Biolchi","twitter_card":"summary_large_image","twitter_creator":"@Tempco_it","twitter_site":"@Tempco_it","twitter_misc":{"Written by":"Valter Biolchi","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/#article","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/"},"author":{"name":"Valter Biolchi","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1"},"headline":"Data center cooling can save energy","datePublished":"2013-11-25T08:13:06+00:00","dateModified":"2023-03-16T12:06:22+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/"},"wordCount":496,"commentCount":0,"publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"articleSection":["Energia Termica @en"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/","url":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/","name":"Data center cooling can save energy - Tempco Blog","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/#website"},"datePublished":"2013-11-25T08:13:06+00:00","dateModified":"2023-03-16T12:06:22+00:00","breadcrumb":{"@id":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.tempco.it\/blog\/en\/4512\/data-center-cooling-can-save-energy\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tempco.it\/blog\/"},{"@type":"ListItem","position":2,"name":"Data center cooling can save energy"}]},{"@type":"WebSite","@id":"https:\/\/www.tempco.it\/blog\/#website","url":"https:\/\/www.tempco.it\/blog\/","name":"Tempco Blog","description":"Solutions for the thermal energy","publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tempco.it\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tempco.it\/blog\/#organization","name":"Tempco Srl","url":"https:\/\/www.tempco.it\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","contentUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2022\/12\/logo_big.jpg","width":317,"height":317,"caption":"Tempco Srl"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tempco.srl","https:\/\/twitter.com\/Tempco_it","https:\/\/www.youtube.com\/c\/TempcoItalia","https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/","https:\/\/www.instagram.com\/tempco_solidtemperature\/"]},{"@type":"Person","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/a045f83b14a8426456a4051d110eb9c1","name":"Valter Biolchi","sameAs":["http:\/\/www.tempco.it"]}]}},"_links":{"self":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/4512"}],"collection":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/comments?post=4512"}],"version-history":[{"count":8,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/4512\/revisions"}],"predecessor-version":[{"id":9108,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/4512\/revisions\/9108"}],"wp:attachment":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/media?parent=4512"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/categories?post=4512"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/tags?post=4512"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}