{"id":11620,"date":"2026-11-19T12:00:21","date_gmt":"2026-11-19T11:00:21","guid":{"rendered":"https:\/\/www.tempco.it\/blog\/?p=11620"},"modified":"2026-11-19T12:00:21","modified_gmt":"2026-11-19T11:00:21","slug":"injection-molding-and-heating-element-failure-in-temperature-control-units-tcus","status":"publish","type":"post","link":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/","title":{"rendered":"Injection molding and heating element failure in temperature control units (TCUs)"},"content":{"rendered":"<p>In precision temperature control, the correct <strong>sizing of <a href=\"https:\/\/en.tempco.it\/solutions-en\/heat-exchangers\/\" target=\"_blank\" rel=\"noopener\">heat exchangers<\/a><\/strong> is more important than having an excess of power. In fact, an oversized heat exchanger was the root cause of <strong>heating element failure in a <a href=\"https:\/\/en.tempco.it\/solutions-en\/thermo-regulating-units\/\" target=\"_blank\" rel=\"noopener\">temperature control unit<\/a><\/strong> (TCU) used for the <a href=\"https:\/\/www.tempco.it\/blog\/en\/10503\/thermoregulation-in-carbon-fiber-composite-materials-molding\/\" target=\"_blank\" rel=\"noopener\"><strong>injection molding<\/strong><\/a> of a PP-based composite material. The client\u2014an overseas company\u2014contacted Tempco to investigate the underlying cause of the malfunction.<\/p>\n<p>Our first step was to <strong>collect process data<\/strong> during an on-site visit conducted by the Tempco partner:<\/p>\n<ul>\n<li>a steel mold weighing ~12 tons, with a throughput of ~60 kg\/h;<\/li>\n<li>4 temperature control zones, managed by 3 TCU operating at 60, 80, and 100 \u00b0C;<\/li>\n<li>cooling water available at 15 \u00b0C;<\/li>\n<li>the material is heated up to ~250 \u00b0C for injection and subsequently cooled down to ~80 \u00b0C;<\/li>\n<li>actual cooling load required: \u0394T 170 \u00b0C \u00d7 60 kg\/h \u00d7 specific heat capacity (Cs) 0.45 \u2248 5.3 kW net;<\/li>\n<li>highly stable process temperature.<\/li>\n<\/ul>\n<p>As previously mentioned, the client\u2019s issue involved the <strong>failure of the heating elements<\/strong> within their temperature control units (TCUs). A joint analysis conducted by Tempco and our local partner identified the likely cause: thermal shock resulting from a significantly <strong>oversized plate heat exchanger<\/strong>\u201460 kW capacity, compared to an actual cooling duty required of only ~5.3 kW. With such an oversized exchanger, combined with an on\/off cooling solenoid valve, every activation delivers a <strong>sudden, disproportionate cooling &#8216;jolt&#8217;<\/strong>. This causes sharp thermal fluctuations in the process water, leading the heating elements to develop cracks and eventually fail. This is a classic example of how over-sizing the capacity of a heat exchanger does not enhance operational reliability.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter  wp-image-11621\" src=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg\" alt=\"Image illustrating a temperature control unit TCU for the injection molding of composite materials.\" width=\"685\" height=\"382\" srcset=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg 1376w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1-300x167.jpg 300w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1-1024x572.jpg 1024w, https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1-768x429.jpg 768w\" sizes=\"auto, (max-width: 685px) 100vw, 685px\" \/><\/p>\n<p><em>Solutions proposed by Tempco<\/em><br \/>\nBasically, our preferred solution would have been to replace the on\/off solenoid valve with a \u00bd&#8221; or \u00be&#8221; <strong>proportional\/modulating valve<\/strong>, allowing for gradual cooling control. However, the ASCON temperature controller installed in the client\u2019s TCU does not support a modulating valve, and retrofitting one would be highly invasive.<br \/>\nThe practical, immediately implementable solution was to install a <strong>manual valve on the cooling water inlet<\/strong> to throttle the flow to a minimum, paired with a solenoid valve properly sized upon this reduced flow rate.<br \/>\nFor future units, it is therefore advisable to install a <strong>heat exchanger sized according to the actual power requirements<\/strong>, equipped with a solenoid valve matched to the minimum necessary flow rate.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Failure of heating elements in a temperature control unit (TCU) used for the injection molding of composite materials; an analysis conducted by Tempco identified the root cause as the oversizing of the plate heat exchanger.<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[64,63,66,87,472,113,473,88,710,76],"tags":[226,127,4900,4897,4893,138,137,4894,2688,4896,123,4895,3456,4898,1543,4271,235,4458,4899,817,1579,128],"class_list":["post-11620","post","type-post","status-publish","format-standard","hentry","category-cooling","category-heat-exchangers","category-heating","category-maintenance","category-manutenzione-en","category-plate-heat-exchanger","category-scambiatori-a-piastre-en","category-service","category-temperature-control-unit","category-thermoregulation-unit","tag-composites","tag-cooling-2","tag-cracking","tag-failure-of-heating-elements","tag-heat-exchanger-calculation","tag-heat-exchangers-2","tag-heating-2","tag-heating-elements","tag-molding","tag-oversizing","tag-plate-heat-exchangers","tag-proportional-valves","tag-sizing","tag-solenoid-valves","tag-solid-temperature","tag-tcu-en","tag-temperature-control","tag-temperature-control-units","tag-temperature-controllers","tag-temperature-regulation","tag-thermal-shock","tag-thermoregulation"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Injection molding and heating element failure in temperature control units (TCUs) - Tempco Blog<\/title>\n<meta name=\"description\" content=\"Failure of heating elements in a temperature control unit (TCU) used for the injection molding of composite materials.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Injection molding and heating element failure in temperature control units (TCUs) - Tempco Blog\" \/>\n<meta property=\"og:description\" content=\"Failure of heating elements in a temperature control unit (TCU) used for the injection molding of composite materials.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/\" \/>\n<meta property=\"og:site_name\" content=\"Tempco Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tempco.srl\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-19T11:00:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1376\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Marco Zambelli\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:site\" content=\"@Tempco_it\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marco Zambelli\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/\"},\"author\":{\"name\":\"Marco Zambelli\",\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/#\\\/schema\\\/person\\\/7b9316f2ae038cf675b9efcabca742f4\"},\"headline\":\"Injection molding and heating element failure in temperature control units (TCUs)\",\"datePublished\":\"2026-11-19T11:00:21+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/\"},\"wordCount\":385,\"publisher\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg\",\"keywords\":[\"composites\",\"cooling\",\"cracking\",\"failure of heating elements\",\"heat exchanger calculation\",\"heat exchangers\",\"heating\",\"heating elements\",\"molding\",\"oversizing\",\"plate heat exchangers\",\"proportional valves\",\"sizing\",\"solenoid valves\",\"solid temperature\",\"TCU\",\"temperature control\",\"temperature control units\",\"temperature controllers\",\"temperature regulation\",\"thermal shock\",\"thermoregulation\"],\"articleSection\":[\"Cooling\",\"Heat exchangers\",\"Heating\",\"Maintenance\",\"Manutenzione\",\"plate heat exchanger\",\"Scambiatori a piastre\",\"Service\",\"temperature control unit\",\"Thermoregulation Unit\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/\",\"url\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/\",\"name\":\"Injection molding and heating element failure in temperature control units (TCUs) - Tempco Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg\",\"datePublished\":\"2026-11-19T11:00:21+00:00\",\"description\":\"Failure of heating elements in a temperature control unit (TCU) used for the injection molding of composite materials.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/en\\\/11620\\\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Injection molding and heating element failure in temperature control units (TCUs)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/\",\"name\":\"Tempco Blog\",\"description\":\"Solutions for the thermal energy\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/#organization\",\"name\":\"Tempco Srl\",\"url\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/tempco-seo-696.jpg\",\"contentUrl\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/tempco-seo-696.jpg\",\"width\":696,\"height\":696,\"caption\":\"Tempco Srl\"},\"image\":{\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/tempco.srl\",\"https:\\\/\\\/x.com\\\/Tempco_it\",\"https:\\\/\\\/www.youtube.com\\\/c\\\/TempcoItalia\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/tempcoitaly\\\/about\\\/\",\"https:\\\/\\\/www.instagram.com\\\/tempco_solidtemperature\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.tempco.it\\\/blog\\\/#\\\/schema\\\/person\\\/7b9316f2ae038cf675b9efcabca742f4\",\"name\":\"Marco Zambelli\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Injection molding and heating element failure in temperature control units (TCUs) - Tempco Blog","description":"Failure of heating elements in a temperature control unit (TCU) used for the injection molding of composite materials.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/","og_locale":"en_US","og_type":"article","og_title":"Injection molding and heating element failure in temperature control units (TCUs) - Tempco Blog","og_description":"Failure of heating elements in a temperature control unit (TCU) used for the injection molding of composite materials.","og_url":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/","og_site_name":"Tempco Blog","article_publisher":"https:\/\/www.facebook.com\/tempco.srl","article_published_time":"2026-11-19T11:00:21+00:00","og_image":[{"width":1376,"height":768,"url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg","type":"image\/jpeg"}],"author":"Marco Zambelli","twitter_card":"summary_large_image","twitter_creator":"@Tempco_it","twitter_site":"@Tempco_it","twitter_misc":{"Written by":"Marco Zambelli","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/#article","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/"},"author":{"name":"Marco Zambelli","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/7b9316f2ae038cf675b9efcabca742f4"},"headline":"Injection molding and heating element failure in temperature control units (TCUs)","datePublished":"2026-11-19T11:00:21+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/"},"wordCount":385,"publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg","keywords":["composites","cooling","cracking","failure of heating elements","heat exchanger calculation","heat exchangers","heating","heating elements","molding","oversizing","plate heat exchangers","proportional valves","sizing","solenoid valves","solid temperature","TCU","temperature control","temperature control units","temperature controllers","temperature regulation","thermal shock","thermoregulation"],"articleSection":["Cooling","Heat exchangers","Heating","Maintenance","Manutenzione","plate heat exchanger","Scambiatori a piastre","Service","temperature control unit","Thermoregulation Unit"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/","url":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/","name":"Injection molding and heating element failure in temperature control units (TCUs) - Tempco Blog","isPartOf":{"@id":"https:\/\/www.tempco.it\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/#primaryimage"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg","datePublished":"2026-11-19T11:00:21+00:00","description":"Failure of heating elements in a temperature control unit (TCU) used for the injection molding of composite materials.","breadcrumb":{"@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/#primaryimage","url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg","contentUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/11\/Tempco-TREG-stampaggio-compositi-rottura-resistenze-1.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.tempco.it\/blog\/en\/11620\/injection-molding-and-heating-element-failure-in-temperature-control-units-tcus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tempco.it\/blog\/"},{"@type":"ListItem","position":2,"name":"Injection molding and heating element failure in temperature control units (TCUs)"}]},{"@type":"WebSite","@id":"https:\/\/www.tempco.it\/blog\/#website","url":"https:\/\/www.tempco.it\/blog\/","name":"Tempco Blog","description":"Solutions for the thermal energy","publisher":{"@id":"https:\/\/www.tempco.it\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tempco.it\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.tempco.it\/blog\/#organization","name":"Tempco Srl","url":"https:\/\/www.tempco.it\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/10\/tempco-seo-696.jpg","contentUrl":"https:\/\/www.tempco.it\/blog\/wp-content\/uploads\/2026\/10\/tempco-seo-696.jpg","width":696,"height":696,"caption":"Tempco Srl"},"image":{"@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tempco.srl","https:\/\/x.com\/Tempco_it","https:\/\/www.youtube.com\/c\/TempcoItalia","https:\/\/www.linkedin.com\/company\/tempcoitaly\/about\/","https:\/\/www.instagram.com\/tempco_solidtemperature\/"]},{"@type":"Person","@id":"https:\/\/www.tempco.it\/blog\/#\/schema\/person\/7b9316f2ae038cf675b9efcabca742f4","name":"Marco Zambelli"}]}},"_links":{"self":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/11620","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/comments?post=11620"}],"version-history":[{"count":1,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/11620\/revisions"}],"predecessor-version":[{"id":11623,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/posts\/11620\/revisions\/11623"}],"wp:attachment":[{"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/media?parent=11620"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/categories?post=11620"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tempco.it\/blog\/en\/wp-json\/wp\/v2\/tags?post=11620"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}