<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>plate heat exchanger Archivi - Tempco Blog</title>
	<atom:link href="https://www.tempco.it/blog/en/category/plate-heat-exchanger/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.tempco.it/blog/en/category/plate-heat-exchanger/</link>
	<description>Solutions for the thermal energy</description>
	<lastBuildDate>Fri, 23 Oct 2026 09:14:48 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>
	<item>
		<title>Liquid cooling and high efficiency heat recovery in data centers</title>
		<link>https://www.tempco.it/blog/en/11570/liquid-cooling-and-high-efficiency-heat-recovery-in-data-centers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 23 Oct 2026 09:14:48 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Energy Saving]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heat recovery]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[AI]]></category>
		<category><![CDATA[artificial intelligence]]></category>
		<category><![CDATA[BPHE]]></category>
		<category><![CDATA[brazed plate]]></category>
		<category><![CDATA[brazed plate heat exchangers]]></category>
		<category><![CDATA[chip]]></category>
		<category><![CDATA[circular economy]]></category>
		<category><![CDATA[cloud computing]]></category>
		<category><![CDATA[cold plates]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[CPU]]></category>
		<category><![CDATA[data center]]></category>
		<category><![CDATA[energy efficiency]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heat recovery]]></category>
		<category><![CDATA[HPC]]></category>
		<category><![CDATA[immersion cooling]]></category>
		<category><![CDATA[liquid cooling]]></category>
		<category><![CDATA[PUE]]></category>
		<category><![CDATA[server]]></category>
		<category><![CDATA[skid]]></category>
		<category><![CDATA[solid sustainability]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[steam]]></category>
		<category><![CDATA[Tempco Green]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11570</guid>

					<description><![CDATA[<p>Liquid cooling and heat recovery systems enhance efficiency and energy savings within data center cooling ecosystems, as higher outlet temperatures make cold plates and immersion cooling even more attractive options.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11570/liquid-cooling-and-high-efficiency-heat-recovery-in-data-centers/">Liquid cooling and high efficiency heat recovery in data centers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><a href="https://www.tempco.it/blog/en/11504/brazed-plate-heat-exchangers-for-liquid-cooling-high-efficiency-computing-density-in-data-centers/" target="_blank" rel="noopener">Liquid cooling</a> in modern data centers</strong> serves as an alternative to traditional air-based cooling. The latter is indeed no longer sufficient to manage and dissipate the vast amounts of heat generated by chips, servers, and CPUs—heat resulting from the increasingly high computing densities required by <strong>cloud computing and artificial intelligence</strong> applications. As a cooling medium, liquid offers a <strong>superior heat transfer coefficient</strong> compared to air, allowing for more efficient and rapid heat removal, while consuming less energy than air-conditioning systems.</p>
<p>Another compelling aspect that further enhances the <strong>energy efficiency of liquid cooling solutions in <a href="https://www.tempco.it/blog/en/11354/brazed-plate-heat-exchangers-for-cdus-in-liquid-cooling-for-data-centers/" target="_blank" rel="noopener">data centers</a></strong> is the potential for implementing <strong><a href="https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/" target="_blank" rel="noopener">heat recovery</a> systems</strong>. Because liquid absorbs heat more efficiently and in a more concentrated manner than air, the temperatures at the cooling system&#8217;s outlet are higher than those achieved with conventional air-based methods. This facilitates the adoption of <strong>highly advantageous energy recovery solutions</strong>, enabling the reused thermal energy to be applied to a variety of purposes—ranging from district heating and <a href="https://www.tempco.it/blog/en/9012/renewables-geothermal-heat-pumps-and-tcoil-exchangers/" target="_blank" rel="noopener"><strong>heat pumps</strong></a> to the heating of domestic hot water or the <strong>preheating of process fluids</strong>. In this way, the energy consumed by data centers—which would otherwise be dissipated as waste heat—is repurposed in line with circular economy principles, thanks to liquid cooling.</p>
<p><img fetchpriority="high" decoding="async" class="aligncenter  wp-image-11571" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-liquid-cooling-data-center-recupero-di-calore-1.jpg" alt="An image illustrating liquid cooling solutions for data centers, where the implementation of heat recovery systems further boosts efficiency and energy saving." width="745" height="505" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-liquid-cooling-data-center-recupero-di-calore-1.jpg 1134w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-liquid-cooling-data-center-recupero-di-calore-1-300x203.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-liquid-cooling-data-center-recupero-di-calore-1-1024x694.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-liquid-cooling-data-center-recupero-di-calore-1-768x520.jpg 768w" sizes="(max-width: 745px) 100vw, 745px" /></p>
<p><strong>Tempco</strong> acts as a qualified system integrator for the implementation of <strong>liquid cooling skids for data centers</strong>, featuring <a href="https://en.tempco.it/solutions-en/heat-exchangers/brazed-plate/" target="_blank" rel="noopener"><strong>brazed plate heat exchangers</strong></a> (BPHEs) as their technological core. There are various possible architectures for liquid cooling ecosystems in data centers (that often can also include <a href="https://en.tempco.it/solutions-en/chillers/" target="_blank" rel="noopener"><strong>chillers</strong></a>, <a href="https://en.tempco.it/solutions-en/industrial-coolers-electroradiators/" target="_blank" rel="noopener"><strong>free cooling</strong></a> and <a href="https://en.tempco.it/solutions-en/cooling-towers/" target="_blank" rel="noopener"><strong>evaporative towers</strong></a>), and for each type, Tempco’s range of BPHEs offers the ideal solution to ensure maximum cooling efficiency and reduced energy consumption, thereby <strong>lowering the Power Usage Effectiveness</strong> (PUE) of computing facilities.</p>
<p>It is therefore worth examining the advantages—as well as some related drawbacks—associated with different liquid cooling options for servers and chips. Whether using <strong>cold plates</strong> (conductive metal plates placed in contact with electronic components to remove generated heat via a coolant circulating through microchannels) or <strong>direct immersion cooling</strong> (where servers are submerged in <a href="https://www.tempco.it/blog/en/10415/dielectric-fluids-in-data-center-and-electronics-components-cooling/" target="_blank" rel="noopener"><strong>dielectric fluids</strong></a>), there are two primary operating modes for the thermal cycle: <strong>single-phase</strong> liquid cooling and <strong>two-phase</strong> liquid cooling. The former involves no phase change of the coolant—which could, for instance, be a 75% water-glycol mixture—offering the advantage of a simpler system design.</p>
<p>In two-phase liquid cooling, the coolant boils either within cold plates or upon direct contact with components submerged in cooling tanks. The <strong>transition to a vapor phase</strong> necessitates a more complex system to manage the vapor, requiring the inclusion of condensers as well as precise control over pressure and temperature levels. Conversely, two-phase liquid cooling enables the removal of large quantities of heat with <strong>significantly higher efficiency</strong> than single-phase methods.</p>
<p>Another aspect involves the <strong>comparison between cold plates and immersion liquid cooling</strong>. The use of cold plates requires <strong>pumping systems and piping to deliver coolant</strong> to the plates positioned on the components, which introduces a risk of leaks that must be carefully monitored. Immersion liquid cooling, by contrast, offers a more streamlined system architecture; it facilitates more uniform cooling and <strong>simplifies inspection and maintenance</strong>—essentially requiring only that the level of the coolant or dielectric fluid in the cooling tank be kept sufficient. On the other hand, despite its simpler system layout, immersion liquid cooling entails <strong>higher initial costs</strong>, driven by the high price of the specialized dielectric fluids required and the need for <strong>custom-built hardware</strong>, which must be constructed using materials compatible with immersion in special cooling liquids (requiring, for instance, careful selection of appropriate adhesives and gaskets).</p>
<p>&nbsp;</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8408/solid-wishes-from-tempco/" title="Permanent link to Solid wishes from Tempco!">Solid wishes from Tempco!</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10952/efficiency-and-operational-continuity-original-spare-parts-make-the-difference/" title="Permanent link to Efficiency and operational continuity: original spare parts make the difference">Efficiency and operational continuity: original spare parts make the difference</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/5843/tempco-100-green-energy/" title="Permanent link to Tempco, 100% Green Energy">Tempco, 100% Green Energy</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/5791/cool-wishes-from-tempco/" title="Permanent link to Cool Wishes from Tempco!">Cool Wishes from Tempco!</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11570/liquid-cooling-and-high-efficiency-heat-recovery-in-data-centers/">Liquid cooling and high efficiency heat recovery in data centers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Pre-tested skid-mounted temperature control units (TCUs) for pharma production</title>
		<link>https://www.tempco.it/blog/en/11558/pre-tested-skid-mounted-temperature-control-units-tcus-for-pharma-production/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 15 Oct 2026 09:38:57 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[3D design]]></category>
		<category><![CDATA[commissioning]]></category>
		<category><![CDATA[compact design]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[Factory Acceptance Test]]></category>
		<category><![CDATA[FAT]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[pharma]]></category>
		<category><![CDATA[pharmaceutical production]]></category>
		<category><![CDATA[plug & play]]></category>
		<category><![CDATA[reactors]]></category>
		<category><![CDATA[revamping]]></category>
		<category><![CDATA[single-fluid system]]></category>
		<category><![CDATA[skid]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[temperature regulation]]></category>
		<category><![CDATA[testing]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11558</guid>

					<description><![CDATA[<p>Temperature Control Units (TCUs) pre-assembled and factory-tested to ensure rapid commissioning for revamping projects in pharma production. These units offer a "plug &#038; play" solution with a compact design, ideal for environments where space is limited.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11558/pre-tested-skid-mounted-temperature-control-units-tcus-for-pharma-production/">Pre-tested skid-mounted temperature control units (TCUs) for pharma production</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>In <strong>pharmaceutical revamping</strong> projects involving <a href="https://en.tempco.it/solutions-en/thermo-regulating-units/heating-cooling-and-thermoregulation-package-units-in-industrial-processes/" target="_blank" rel="noopener"><strong>temperature control units</strong></a> (TCUs)—where space is extremely limited—assembling a unit piece-by-piece on-site represents a significant risk. The solution is a <strong>pre-assembled and pre-tested temperature control skid</strong>.</p>
<p>Such applications in <a href="https://www.tempco.it/blog/en/11457/design-upon-batch-thermal-duty-changes-the-rules-in-pharma/" target="_blank" rel="noopener"><strong>pharma productions</strong></a> highlight the added value of a pre-tested temperature control skid, starting with its compact design. Each TCU is <strong>engineered in 3D to maximize every available centimeter</strong>, with tolerances down to the millimeter.</p>
<p><img decoding="async" class="aligncenter  wp-image-11560" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-skid-termoregolazione-TCU-pharma-1.jpg" alt="The image shows a glass-lined reactor used in pharmaceutical production, paired with a pre-assembled and factory-tested TCU skid, ensuring &quot;plug &amp; play&quot; installation and quick commissioning." width="580" height="387" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-skid-termoregolazione-TCU-pharma-1.jpg 1300w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-skid-termoregolazione-TCU-pharma-1-300x200.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-skid-termoregolazione-TCU-pharma-1-1024x683.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-skid-termoregolazione-TCU-pharma-1-768x512.jpg 768w" sizes="(max-width: 580px) 100vw, 580px" /></p>
<p>Another major advantage is the <strong>&#8220;plug-and-play&#8221; quality achieved in the workshop</strong>: welding, wiring, and testing of the TCU are all performed in a controlled environment—rather than in the chaotic setting of a construction site or a potentially hazardous (ATEX) area. This ensures that on-site installation and commissioning of the TCU proceed without any unexpected issues.</p>
<p>This is ensured by the <strong>Factory Acceptance Test (FAT) of the TCU skid</strong>, through which the unit is tested at the workshop and therefore shipped in full working order. Once it arrives at the customer’s facility, only the connections to the utility lines (‘border line’ connections) are required; the system is then ready to start up within a few hours, eliminating downtime and last-minute unforeseen issues.</p>
<p><iframe title="TREG Freddo raffreddamento monofluido" width="750" height="422" src="https://www.youtube.com/embed/cKjY6Fgptlw?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" title="Permanent link to Temperature control units for reactors at -30° C in the pharma industry">Temperature control units for reactors at -30° C in the pharma industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11485/atex-zone-tcu-temperature-control-units-maximum-efficiency-with-control-panel-in-safe-area/" title="Permanent link to ATEX zone TCU temperature control units, maximum efficiency with control panel in safe area">ATEX zone TCU temperature control units, maximum efficiency with control panel in safe area</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10426/treg-thermoregulation-units-in-automotive-and-ev-test-benches/" title="Permanent link to TREG thermoregulation units in automotive and EV test benches">TREG thermoregulation units in automotive and EV test benches</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11457/design-upon-batch-thermal-duty-changes-the-rules-in-pharma/" title="Permanent link to Design upon ‘batch’: thermal duty changes the rules in pharma">Design upon ‘batch’: thermal duty changes the rules in pharma</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11558/pre-tested-skid-mounted-temperature-control-units-tcus-for-pharma-production/">Pre-tested skid-mounted temperature control units (TCUs) for pharma production</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>All-stainless steel brazed plate heat exchangers for high water purity</title>
		<link>https://www.tempco.it/blog/en/11536/all-stainless-steel-brazed-plate-heat-exchangers-for-high-water-purity/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 09 Oct 2026 09:48:35 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[corrosion]]></category>
		<category><![CDATA[Corrosione]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[all-stainless steel]]></category>
		<category><![CDATA[brazed plate heat exchangers]]></category>
		<category><![CDATA[chemical industry]]></category>
		<category><![CDATA[contamination]]></category>
		<category><![CDATA[corrosione]]></category>
		<category><![CDATA[deionized water]]></category>
		<category><![CDATA[demineralized water]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[electrolyzers]]></category>
		<category><![CDATA[energy]]></category>
		<category><![CDATA[food industry]]></category>
		<category><![CDATA[fuel cells]]></category>
		<category><![CDATA[Full inox]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[hydrogen]]></category>
		<category><![CDATA[Kaori]]></category>
		<category><![CDATA[leaching]]></category>
		<category><![CDATA[pharmaceutical]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[semiconductors]]></category>
		<category><![CDATA[solid temperature]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11536</guid>

					<description><![CDATA[<p>Tempco TCBS series all-stainless steel brazed plate exchangers for applications requiring high water purity and corrosion resistance—handling demineralized water in the hydrogen industry (fuel cells and electrolyzers), semiconductor manufacturing, and the food, chemical and pharma. </p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11536/all-stainless-steel-brazed-plate-heat-exchangers-for-high-water-purity/">All-stainless steel brazed plate heat exchangers for high water purity</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Using copper in <a href="https://en.tempco.it/solutions-en/heat-exchangers/brazed-plate/" target="_blank" rel="noopener"><strong>brazed plate heat exchangers</strong></a> for deionized and demineralized water applications can lead to fluid contamination and damage to the exchanger itself. For heating and cooling applications requiring <strong>high water purity and exceptional corrosion resistance</strong>, the solution is to choose all-stainless steel brazed plate heat exchangers.</p>
<p>To meet this need, Tempco offers the new <strong>TCBS series of brazed plate heat exchangers made entirely of stainless steel</strong> and featuring brazing with a copper-free stainless steel alloy. These exchangers are therefore the ideal choice for a wide range of applications—from the <a href="https://www.tempco.it/blog/en/11151/brazed-plate-exchangers-for-hydrogen-applications-electrolysis-and-fuel-cells/" target="_blank" rel="noopener"><strong>hydrogen industry</strong></a> in <a href="https://www.tempco.it/blog/en/9951/heat-exchangers-hydrogen-cooling-and-fuel-cells/" target="_blank" rel="noopener"><strong>fuel cells</strong></a> and electrolyzers, to <strong>semiconductor</strong> manufacturing, the<strong> food industry</strong>, the <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" target="_blank" rel="noopener"><strong>chemical and pharmaceutical</strong></a> sectors, and any processes requiring the handling of pure or demineralized water.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11537" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1.jpg" alt="Image showing the Tempco TCBS all-stainless steel brazed plate heat exchangers series for applications requiring high water purity." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-1-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /></p>
<p>The absence of copper in the brazing of these heat exchangers <strong>eliminates the risk of copper ion contamination</strong>; such ions can be released upon contact with demineralized water through a process known as <strong>leaching</strong>, which can eventually lead to perforation of the heat exchanger. Compared to traditional gasketed plate heat exchangers, brazed models allow for <strong>stable operating pressures</strong>—standard <strong>versions rated at 10 bar</strong> (A) or <strong>20 bar</strong> (B)—along with a wide operating temperature range and superior corrosion resistance. These factors contribute to high heat transfer efficiency, long service life, and an excellent cost-to-performance ratio. Their greater compactness compared to shell-and-tube solutions also makes the TCBS <strong>ideal for applications with limited space</strong>.</p>
<p>The Tempco TCBS series of all-stainless steel brazed plate heat exchangers is <strong>available in seven sizes</strong> to meet diverse production needs, ranging from low to high flow rates. <strong>Custom configurations and connection options</strong> are also available upon request. The TCBS series corresponds to the &#8220;S &#8211; All Stainless BPHE&#8221; series manufactured by Kaori Heat Treatment Co., Ltd. (Taiwan).</p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="wp-image-11539 aligncenter" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1.jpg" alt="Image showing the Tempco TCBS all-stainless steel brazed plate heat exchanger series for applications requiring high water purity, specifically involving deionized and demineralized water." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-2-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /><br />
<img loading="lazy" decoding="async" class="aligncenter  wp-image-11541" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1.jpg" alt="Image showing the Tempco TCBS all-stainless steel brazed plate heat exchanger series for applications requiring high water purity and high corrosion resistance." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-3-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /><br />
<img loading="lazy" decoding="async" class="aligncenter  wp-image-11543" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1.jpg" alt="Image showing the models and sizes of the Tempco TCBS all-stainless steel brazed plate heat exchanger series for applications requiring high water purity and high corrosion resistance." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-4-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /></p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11545" src="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1.jpg" alt="Image showing the application sectors for the Tempco TCBS all-stainless steel brazed plate heat exchanger series, designed for applications requiring high water purity and high corrosion resistance." width="628" height="888" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1.jpg 962w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1-212x300.jpg 212w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1-724x1024.jpg 724w, https://www.tempco.it/blog/wp-content/uploads/2026/10/Tempco-TCBS-scambiatori-saldobrasati-full-inox-5-1-768x1087.jpg 768w" sizes="auto, (max-width: 628px) 100vw, 628px" /></p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8581/special-plate-heat-exchangers-for-oilgas-applications/" title="Permanent link to Special plate heat exchangers for oil&#038;gas applications">Special plate heat exchangers for oil&#038;gas applications</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/7833/fouling-factor-in-heat-exchangers-and-nanocoatings/" title="Permanent link to Fouling factor in heat exchangers and nanocoatings">Fouling factor in heat exchangers and nanocoatings</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11182/brazed-plate-heat-exchangers-in-hydraulic-power-plants/" title="Permanent link to Brazed plate heat exchangers in hydraulic power plants">Brazed plate heat exchangers in hydraulic power plants</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10896/precision-and-hygiene-in-stainless-steel-for-pharma-and-food-thermoregulation/" title="Permanent link to Precision and hygiene in stainless steel for pharma and food thermoregulation">Precision and hygiene in stainless steel for pharma and food thermoregulation</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9827/chillers-exchangers-and-separators-for-biogas-treatment/" title="Permanent link to Chillers, exchangers and separators for biogas treatment">Chillers, exchangers and separators for biogas treatment</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11536/all-stainless-steel-brazed-plate-heat-exchangers-for-high-water-purity/">All-stainless steel brazed plate heat exchangers for high water purity</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Brazed plate heat exchangers for liquid cooling: high-efficiency computing density in data centers</title>
		<link>https://www.tempco.it/blog/en/11504/brazed-plate-heat-exchangers-for-liquid-cooling-high-efficiency-computing-density-in-data-centers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 24 Sep 2026 14:37:26 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Energy Saving]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[AI]]></category>
		<category><![CDATA[BPHE]]></category>
		<category><![CDATA[CDU]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[chip]]></category>
		<category><![CDATA[cold plates]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[data center]]></category>
		<category><![CDATA[dielectric fluids]]></category>
		<category><![CDATA[direct to chip]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[energy saving]]></category>
		<category><![CDATA[evaporation]]></category>
		<category><![CDATA[free cooling]]></category>
		<category><![CDATA[GPU]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heat transfer]]></category>
		<category><![CDATA[HPC]]></category>
		<category><![CDATA[immersion cooling]]></category>
		<category><![CDATA[in rack]]></category>
		<category><![CDATA[in row]]></category>
		<category><![CDATA[liquid cooling]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[PUE]]></category>
		<category><![CDATA[server]]></category>
		<category><![CDATA[solid sustainability]]></category>
		<category><![CDATA[sustainability]]></category>
		<category><![CDATA[Tempco Green]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11504</guid>

					<description><![CDATA[<p>Tempco brazed plate heat exchangers (BPHEs) in CDUs used for liquid cooling, employing cold plates technology or direct hardware immersion in dielectric fluids, for the sustainable cooling of high-power-density data centers.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11504/brazed-plate-heat-exchangers-for-liquid-cooling-high-efficiency-computing-density-in-data-centers/">Brazed plate heat exchangers for liquid cooling: high-efficiency computing density in data centers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>In <a href="https://www.tempco.it/blog/en/11110/high-efficiency-exchangers-for-liquid-cooling-in-ai-hpc-data-centers/" target="_blank" rel="noopener"><strong>data centers</strong></a>, the shift from air cooling to <strong>liquid cooling</strong> techniques offers significant advantages regarding energy savings and superior cooling efficiency. It enables increased computing density and, overall, improves the sustainability of large-scale high-performance computing infrastructures.</p>
<p>Today, the rapid and continuous rise in heat amounts from chips renders traditional air-conditioning systems inadequate. <strong>Tempco BPHE</strong> <a href="https://en.tempco.it/solutions-en/heat-exchangers/brazed-plate/" target="_blank" rel="noopener"><strong>brazed plate heat exchangers</strong></a>—also available in an all-stainless-steel version—are the technological heart of this shift to liquid cooling; they act as a key technological enabler that brings sustainability to data centers by <strong>reducing PUE (Power Usage Effectiveness)</strong> while simultaneously allowing for increased rack density.</p>
<p>The superior performance of liquid cooling stems primarily from the fact that liquids are more efficient than air at transferring heat, allowing for <strong>more effective heat dissipation and lower energy consumption</strong> for the same amounts of heat removed. This makes it possible to reliably manage the higher power densities typical of AI and HPC applications—delivering high performance in a more eco-friendly manner. Furthermore, liquid cooling allows for highly targeted and precise cooling, as liquids are easier to direct toward specific components than air. The cooling ecosystem is completed by <a href="https://en.tempco.it/solutions-en/industrial-coolers-electroradiators/" target="_blank" rel="noopener"><strong>free-cooling</strong></a> systems and <a href="https://en.tempco.it/solutions-en/chillers/" target="_blank" rel="noopener"><strong>chillers</strong></a> located outside the data center; these dissipate the heat extracted from the servers and conveyed outdoors via the BPHE exchangers.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-11505" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1.jpg" alt="Image illustrating the applications of Tempco BPHE (brazed plate heat exchangers) in CDUs for liquid cooling in high-power-density data centers." width="721" height="721" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1.jpg 1361w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1-300x300.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1-1024x1024.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1-150x150.jpg 150w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-di-calore-saldobrasati-liquid-cooling-CDU-data-center-1-768x768.jpg 768w" sizes="auto, (max-width: 721px) 100vw, 721px" /></p>
<p>Tempco supplies brazed plate heat exchangers (BPHEs) for <strong>data center liquid cooling</strong>, offering models and versions suitable for every type of liquid cooling method, regardless of the system architecture. Their highly compact design allows for easy integration into the <a href="https://www.tempco.it/blog/en/11354/brazed-plate-heat-exchangers-for-cdus-in-liquid-cooling-for-data-centers/" target="_blank" rel="noopener"><strong>Coolant Distribution Units (CDUs)</strong></a> found in liquid cooling systems, thereby saving space within the installation. Tempco’s process expertise and capability to manufacture integrated solutions—such as complete skid systems—offer a further advantage to data center manufacturers and operators, enabling the creation of compact, comprehensive solutions that are easy to install and integrate into computing infrastructures.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11507" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1.jpg" alt="" width="761" height="431" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1.jpg 1701w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1-300x170.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1-1024x580.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1-768x435.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-architettura-in-row-1-1536x870.jpg 1536w" sizes="auto, (max-width: 761px) 100vw, 761px" /></p>
<p>Tempco’s brazed plate exchangers are suitable for use in both <strong>cold plates and immersion cooling systems</strong>—the two main liquid cooling methods used in data centers. The product range covers a wide power spectrum, offering models from 5 to 200 kW for in-rack CDUs and units capable of handling 500 kW to 3 MW for stand-alone in-row CDUs.</p>
<p>Tempco’s range of brazed plate heat exchangers includes models designed for <strong>Direct-to-Chip (DTC) liquid cooling architectures</strong> that utilize <strong>cold plates</strong>. Cold plates technology employs conductive metal plates applied directly to high-power electronic components, such as GPUs and CPUs. The generated heat is absorbed by a coolant circulating through microchannel structures within the cold plates. In this liquid cooling system, the <strong>CDU acts as a hydraulic safety barrier</strong>: here, the overheated fluid arriving from the cold plates flows to the BPHE; once cooled, it is recirculated into the loop, remaining isolated from the external cooling water circuit (free cooler, chiller, and evaporative towers) and thereby protecting the IT equipment from potential contamination.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11509" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-scaled.jpg" alt="Image illustrating in-row and in-rack CDU liquid cooling architectures for data centers, showing the integrated placement of the Tempco BPHE brazed plate heat exchanger." width="760" height="407" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-scaled.jpg 2560w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-300x161.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-1024x548.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-768x411.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-1536x822.jpg 1536w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-data-center-liquid-cooling-architettura-in-row-CDU-in-rack-1-2048x1096.jpg 2048w" sizes="auto, (max-width: 760px) 100vw, 760px" /></p>
<p>Tempco offers brazed plate heat exchangers for CDUs in liquid cooling solutions using cold plates for both <strong>&#8220;in-rack&#8221; architectures</strong>—where the exchangers&#8217; compact size allows for easy CDU integration within server cabinets—and <strong>&#8220;in-row&#8221; setups</strong>, featuring standalone CDU cabinets separate from individual IT racks that can serve up to 10 servers simultaneously.</p>
<p>The product range also includes brazed plate heat exchangers (BPHEs) for <strong>immersion liquid cooling solutions</strong>. Unlike cold plates—which are applied directly to high-power chips and components, typically requiring hybrid solutions that rely on air cooling for other parts of the computing infrastructure—immersion liquid cooling involves submerging all hardware in dedicated tanks containing special <a href="https://www.tempco.it/blog/en/9628/liquid-cooling-and-immersion-exchangers-in-data-centers/" target="_blank" rel="noopener"><strong>dielectric fluids</strong></a>. This ensures uniform cooling across all components, thereby eliminating hot spots.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11511" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1.jpg" alt="Image illustrating an immersion liquid cooling architecture for data centers featuring Tempco BPHE brazed plate heat exchangers.
" width="760" height="427" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1.jpg 1701w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1-300x169.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1-1024x576.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1-768x432.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-BPHE-CDU-data-center-liquid-cooling-immersione-1-1536x863.jpg 1536w" sizes="auto, (max-width: 760px) 100vw, 760px" /></p>
<p>Finally, whether used with cold plates or immersion cooling,Tempco offers brazed plate exchangers optimized for <strong>single-phase liquid cooling</strong> systems, where the coolant (often a water-glycol mixture) remains in the liquid phase throughout the thermal cycle, as well as for <strong>two-phase cooling systems</strong>, where the coolant boils upon contact with the cold plate or the overheated servers. This two-phase approach offers superior cooling efficiency, making it ideal for high workloads and ultra-high-density racks; however, it requires a more complex cooling circuit to manage evaporation phases and ensure precise pressure and temperature control.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11354/brazed-plate-heat-exchangers-for-cdus-in-liquid-cooling-for-data-centers/" title="Permanent link to Brazed plate heat exchangers for CDUs in liquid cooling for data centers">Brazed plate heat exchangers for CDUs in liquid cooling for data centers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10747/pche-heat-exchangers-for-the-energy-transition-market/" title="Permanent link to PCHE heat exchangers for the energy transition market">PCHE heat exchangers for the energy transition market</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9796/tempco-green-a-new-thermal-energy-for-a-solid-sustainability/" title="Permanent link to Tempco Green, a new thermal energy for a solid sustainability">Tempco Green, a new thermal energy for a solid sustainability</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9404/present-and-future-of-thermal-energy-in-the-second-e-book-tempco/" title="Permanent link to Present and future of thermal energy in the second e-book Tempco">Present and future of thermal energy in the second e-book Tempco</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11504/brazed-plate-heat-exchangers-for-liquid-cooling-high-efficiency-computing-density-in-data-centers/">Brazed plate heat exchangers for liquid cooling: high-efficiency computing density in data centers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ATEX zone TCU temperature control units, maximum efficiency with control panel in safe area</title>
		<link>https://www.tempco.it/blog/en/11485/atex-zone-tcu-temperature-control-units-maximum-efficiency-with-control-panel-in-safe-area/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 17 Sep 2026 09:24:51 +0000</pubDate>
				<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[Maintenance]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[Atex]]></category>
		<category><![CDATA[cloud]]></category>
		<category><![CDATA[control panel]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[electronics]]></category>
		<category><![CDATA[explosion proof]]></category>
		<category><![CDATA[explosion risk]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[HMI]]></category>
		<category><![CDATA[monitoring]]></category>
		<category><![CDATA[PID]]></category>
		<category><![CDATA[plc]]></category>
		<category><![CDATA[reliability]]></category>
		<category><![CDATA[remote control]]></category>
		<category><![CDATA[safety]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[TCU]]></category>
		<category><![CDATA[temperature control]]></category>
		<category><![CDATA[temperature control units]]></category>
		<category><![CDATA[temperature regulation]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11485</guid>

					<description><![CDATA[<p>For ATEX-zone temperature control units (TCU), maximum temperature control efficiency can be achieved through a dual configuration: by installing the control panel in a safe zone, advanced electronics can be used without the constraints imposed by ATEX regulations.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11485/atex-zone-tcu-temperature-control-units-maximum-efficiency-with-control-panel-in-safe-area/">ATEX zone TCU temperature control units, maximum efficiency with control panel in safe area</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The highest level of safety for <a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener"><strong>temperature control units</strong></a> (TCU) in <a href="https://www.tempco.it/blog/en/7371/thermoregulating-units-for-hazardous-area-ratings-in-usa/" target="_blank" rel="noopener"><strong>ATEX zones</strong></a> is achieved by installing the control panel outside the explosive hazard area, adopting a dual-configuration approach.</p>
<p>In a <a href="https://www.tempco.it/blog/en/10534/safe-reliable-and-efficient-thermoregulation-in-atex-zone/" target="_blank" rel="noopener"><strong>previous post</strong></a>, we explored the challenges and solutions regarding <strong>temperature control in ATEX environments</strong>, focusing on the design of safe and efficient thermoregulation units. As previously mentioned, one of the most effective strategies for optimizing temperature control in these applications is to <strong>separate the control panel from the hazardous area</strong> by installing it in a safe zone. This configuration offers numerous advantages in terms of safety, reliability, and operational management.</p>
<p><strong>Dual-configuration approach</strong>: ATEX TCU + Remote control<br />
To ensure optimal temperature control in explosive hazard zones, temperature control units (TCUs) are frequently designed as two separate units:</p>
<ul>
<li>The TCU itself, installed within the ATEX area</li>
<li>A remote control panel, positioned in a safe zone</li>
</ul>
<p>This solution <strong>eliminates the need for complex electronic devices within the ATEX area</strong>, thereby reducing the risk of failure and simplifying maintenance.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-11486" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-centralina-termoregolazione-TCU-Atex-doppia-configurazione-1.jpg" alt="Image showing a temperature control unit (TCU); for ATEX zone installations, a dual configuration with a separate control panel in a safe zone allows to use advanced electronics to ensure maximum efficiency and reliability." width="620" height="700" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-centralina-termoregolazione-TCU-Atex-doppia-configurazione-1.jpg 1064w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-centralina-termoregolazione-TCU-Atex-doppia-configurazione-1-266x300.jpg 266w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-centralina-termoregolazione-TCU-Atex-doppia-configurazione-1-906x1024.jpg 906w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-centralina-termoregolazione-TCU-Atex-doppia-configurazione-1-768x868.jpg 768w" sizes="auto, (max-width: 620px) 100vw, 620px" /></p>
<p>The dual-configuration solution therefore comprises several key components:</p>
<ol>
<li><strong>Temperature Control Unit (TCU) in the ATEX zone</strong><br />
The unit installed in the ATEX zone houses all components involved in the temperature control process, designed with appropriate protection measures:<br />
• <a href="https://en.tempco.it/solutions-en/heat-exchangers/" target="_blank" rel="noopener"><strong>Heat exchangers</strong></a> and thermal circuits constructed using materials and configurations compliant with ATEX standards.<br />
• Explosion-proof electric heating elements.<br />
• Intrinsically safe certified temperature sensors (PT100, thermocouples).<br />
• Actuators and valves with Ex d or Ex i protection for thermal flow control.<br />
• Special shielded and insulated wiring to prevent overheating and leakage.</li>
<li><strong>Control panel in the safe zone</strong><br />
The heart of the temperature control system is located in a non-hazardous area, allowing for the implementation of <strong>advanced electronics without ATEX constraints</strong>:• Industrial PLC for temperature management featuring advanced PID control.<br />
• Touchscreen HMI for monitoring and manually adjusting TCU parameters.<br />
• Data logging and reporting capabilities for thermal performance analysis.<br />
• Remote management via connection to SCADA or cloud systems.</li>
</ol>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Image showing a temperature control unit (TCU); for ATEX zone installations, a dual configuration with a separate control panel in a safe zone allows for the use of advanced electronics to ensure maximum efficiency and reliability.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/10426/treg-thermoregulation-units-in-automotive-and-ev-test-benches/" title="Permanent link to TREG thermoregulation units in automotive and EV test benches">TREG thermoregulation units in automotive and EV test benches</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" title="Permanent link to Temperature control units for reactors at -30° C in the pharma industry">Temperature control units for reactors at -30° C in the pharma industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10952/efficiency-and-operational-continuity-original-spare-parts-make-the-difference/" title="Permanent link to Efficiency and operational continuity: original spare parts make the difference">Efficiency and operational continuity: original spare parts make the difference</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10387/strength-and-resistance-with-thermoregulation-in-carbon-fiber-production/" title="Permanent link to Strength and resistance with thermoregulation in carbon fiber production">Strength and resistance with thermoregulation in carbon fiber production</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11485/atex-zone-tcu-temperature-control-units-maximum-efficiency-with-control-panel-in-safe-area/">ATEX zone TCU temperature control units, maximum efficiency with control panel in safe area</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Brazed plate heat exchangers: when immediate availability makes the difference</title>
		<link>https://www.tempco.it/blog/en/11476/brazed-plate-heat-exchangers-when-immediate-availability-makes-the-difference/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 10 Sep 2026 09:19:07 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[Maintenance]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[Service]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[brazed plate]]></category>
		<category><![CDATA[compact footprint]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[exchangers]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heat transfer]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[immediate delivery]]></category>
		<category><![CDATA[plant downtime]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[stainless steel]]></category>
		<category><![CDATA[stock]]></category>
		<category><![CDATA[warehouse]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11476</guid>

					<description><![CDATA[<p>Brazed plate heat exchangers available for immediate delivery from Tempco to meet urgent needs and replacement requirements; the Italian warehouse stock of over 1,000 units is crucial for preventing plant and production downtime.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11476/brazed-plate-heat-exchangers-when-immediate-availability-makes-the-difference/">Brazed plate heat exchangers: when immediate availability makes the difference</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Market lead times for the delivery of <a href="https://en.tempco.it/solutions-en/heat-exchangers/brazed-plate/" target="_blank" rel="noopener"><strong>brazed plate heat exchangers</strong></a> have recently increased significantly, often stretching into weeks or months. At <strong>Tempco</strong>, we have taken a different approach: we <strong>stock over 1,000 brazed plate heat exchangers in Italy</strong>, ready for immediate shipment, to meet the majority of common requests without delay.</p>
<p><a href="https://www.tempco.it/blog/en/11182/brazed-plate-heat-exchangers-in-hydraulic-power-plants/" target="_blank" rel="noopener"><strong>Brazed plate heat exchangers</strong></a> consist of stainless steel plates joined via <strong>copper or nickel brazing</strong>. They offer maximum heat transfer efficiency within a <strong>compact footprint</strong>, making them ideal for heat transfer where space is limited. Furthermore, the brazing process creates a plate pack with superior mechanical strength, enabling operation at <strong>higher pressures</strong> and across <strong>wider temperature ranges</strong>.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11477" src="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-pronta-consegna-1.jpg" alt="Image showing a range of brazed plate heat exchangers—a type of unit Tempco offers for immediate delivery, thanks to an Italian warehouse stock of over 1,000 units." width="551" height="550" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-pronta-consegna-1.jpg 610w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-pronta-consegna-1-300x300.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/09/Tempco-scambiatori-saldobrasati-pronta-consegna-1-150x150.jpg 150w" sizes="auto, (max-width: 551px) 100vw, 551px" /></p>
<p>Immediate availability applies to models with standard connections and ports up to 2&#8243;. By focusing on the most common sizes and configurations, Tempco can <strong>respond promptly to urgent needs, replacement requests, and equipment downtime</strong>. In such situations, the quick delivery of a heat exchanger makes the difference between getting a system back up and running immediately vs suffering costly shutdowns.</p>
<p>Let’s discuss your needs<br />
If you have a system to complete, a machine that is down, or wish to get ahead of market price increases, please <strong><a href="https://en.tempco.it/contacts/" target="_blank" rel="noopener">contact us</a> with the required size and connection specifications</strong>; we will check immediate availability and shipping times together.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8691/service-efficiency-heat-exchangers-and-enjoy-august/" title="Permanent link to Service, efficiency, heat exchangers and… Enjoy August!">Service, efficiency, heat exchangers and… Enjoy August!</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8550/preventive-maintenance-for-heat-exchangers-efficiency/" title="Permanent link to Preventive maintenance for heat exchangers efficiency">Preventive maintenance for heat exchangers efficiency</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10192/importance-of-maintenance-in-plate-heat-exchangers-and-replacement-of-gaskets/" title="Permanent link to Importance of maintenance in plate heat exchangers and replacement of gaskets">Importance of maintenance in plate heat exchangers and replacement of gaskets</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/" title="Permanent link to Tempco&#8217;s spare parts ordering guide for plate heat exchangers">Tempco&#8217;s spare parts ordering guide for plate heat exchangers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8449/mechanical-and-engineering-advantages-of-plate-exchangers-in-hydraulics/" title="Permanent link to Mechanical and engineering advantages of plate exchangers in hydraulics">Mechanical and engineering advantages of plate exchangers in hydraulics</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11476/brazed-plate-heat-exchangers-when-immediate-availability-makes-the-difference/">Brazed plate heat exchangers: when immediate availability makes the difference</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cutting oil cooling with immersion heat exchangers</title>
		<link>https://www.tempco.it/blog/en/11467/cutting-oil-cooling-with-immersion-heat-exchangers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Thu, 03 Sep 2026 10:45:15 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Corrosione]]></category>
		<category><![CDATA[Evaporative Towers]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Immerged heat exchangers]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[cutting oil]]></category>
		<category><![CDATA[evaporative towers]]></category>
		<category><![CDATA[gear manufacturing]]></category>
		<category><![CDATA[gears]]></category>
		<category><![CDATA[harsh environments]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[immersion heat exchangers]]></category>
		<category><![CDATA[machine shops]]></category>
		<category><![CDATA[machine tools]]></category>
		<category><![CDATA[machining]]></category>
		<category><![CDATA[precision]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[stainless steel]]></category>
		<category><![CDATA[tcoil]]></category>
		<category><![CDATA[thermal duty]]></category>
		<category><![CDATA[tolerances]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11467</guid>

					<description><![CDATA[<p>TCOIL immersion heat exchangers for cutting oil cooling in gear manufacturing; minimal installation and maximum efficiency achieved through heat transfer with direct contact with the fluid via immersion in the oil collection tank.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11467/cutting-oil-cooling-with-immersion-heat-exchangers/">Cutting oil cooling with immersion heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>In precision machining workshops, <strong>cutting oil</strong> in the collection tank heats up during the work shift, negatively affecting machining operations and tooling, specifically impacting <strong>machining precision and tolerances</strong>. A Tempco <strong>gear-manufacturing</strong> customer reported an issue with a tank that would exceed 45°C within just a few hours due to the lack of a dedicated cooling circuit.</p>
<p>The simplest and least intrusive solution for this specific application was a <strong>stainless steel <a href="https://en.tempco.it/solutions-en/heat-exchangers/dimple-jacket/" target="_blank" rel="noopener">TCOIL heat exchanger</a></strong> immersed directly into the cutting oil tank. This solution required no machine modifications, allows for <strong>direct heat transfer with the oil</strong>, and can be supplied with water from a <a href="https://en.tempco.it/solutions-en/cooling-towers/" target="_blank" rel="noopener">cooling tower</a>, <a href="https://en.tempco.it/solutions-en/chillers/" target="_blank" rel="noopener">chiller</a>, or well.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-11468" src="https://www.tempco.it/blog/wp-content/uploads/2026/08/Tempco-raffreddamento-olio-da-taglio-scambiatore-TCOIL-a-immersione-1.jpg" alt="Image illustrating a TCOIL immersion heat exchanger for cooling cutting oil in a machining workshop; it offers minimal installation requirements and direct heat transfer with the oil through direct immersion in the collection tank." width="660" height="369" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/08/Tempco-raffreddamento-olio-da-taglio-scambiatore-TCOIL-a-immersione-1.jpg 1304w, https://www.tempco.it/blog/wp-content/uploads/2026/08/Tempco-raffreddamento-olio-da-taglio-scambiatore-TCOIL-a-immersione-1-300x167.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/08/Tempco-raffreddamento-olio-da-taglio-scambiatore-TCOIL-a-immersione-1-1024x572.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/08/Tempco-raffreddamento-olio-da-taglio-scambiatore-TCOIL-a-immersione-1-768x429.jpg 768w" sizes="auto, (max-width: 660px) 100vw, 660px" /></p>
<p>The solution proposed by Tempco therefore offers <strong>several advantages for this application</strong>:</p>
<ul>
<li>Minimal installation: the <a href="https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/" target="_blank" rel="noopener">TCOIL immersion heat exchanger</a> is placed directly into the cutting oil tank, requiring no machine modifications or additional process piping.</li>
<li><strong>Direct fluid contact</strong>: heat exchange occurs directly within the oil, eliminating the need for pumps or secondary circuits on the process side.</li>
<li><strong>Customized materials</strong>: <strong>AISI 304/316 stainless steel</strong> to withstand oil, emulsions, and harsh environments.</li>
<li><strong>Flexible supply</strong>: the coil can be fed with cooling tower water, chiller water, or well water; knowing the cooling water temperature and availability is crucial for sizing the unit.</li>
</ul>
<p>Finally, the secret to a successful solution—ensuring maximum cooling effectiveness and efficiency—lies in the initial stage: <strong>measuring the actual thermal duty</strong> (volume, ΔT, operating hours) and sizing the system accordingly. To this end, before developing a proposal, Tempco’s technical team always conducts a site visit at the customer&#8217;s facility.</p>
<p>&nbsp;</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8266/tcoil-plate-exchangers-in-galvanic-baths/" title="Permanent link to TCOIL plate exchangers in galvanic baths">TCOIL plate exchangers in galvanic baths</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8024/special-materials-in-anodic-oxidation-bath-cooling/" title="Permanent link to Special materials in anodic oxidation bath cooling">Special materials in anodic oxidation bath cooling</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8514/immersion-cooling-and-towers-in-die-casting-foundry/" title="Permanent link to Immersion cooling and towers in die casting foundry">Immersion cooling and towers in die casting foundry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9733/hydrogen-and-thermal-management-for-the-green-energy-industry/" title="Permanent link to Hydrogen and thermal management for the Green Energy Industry">Hydrogen and thermal management for the Green Energy Industry</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11467/cutting-oil-cooling-with-immersion-heat-exchangers/">Cutting oil cooling with immersion heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Wastewater heat recovery with custom immersion plate heat exchangers</title>
		<link>https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 24 Jul 2026 10:27:22 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[corrosion]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Energy Saving]]></category>
		<category><![CDATA[Fouling factor]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heat recovery]]></category>
		<category><![CDATA[Immerged heat exchangers]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[AISI 316L]]></category>
		<category><![CDATA[beverage]]></category>
		<category><![CDATA[chemical]]></category>
		<category><![CDATA[custom]]></category>
		<category><![CDATA[energy efficiency]]></category>
		<category><![CDATA[energy saving]]></category>
		<category><![CDATA[food]]></category>
		<category><![CDATA[fouling]]></category>
		<category><![CDATA[fouling factor]]></category>
		<category><![CDATA[heat recovery]]></category>
		<category><![CDATA[heat transfer]]></category>
		<category><![CDATA[immersion plate heat exchangers]]></category>
		<category><![CDATA[parboiled rice]]></category>
		<category><![CDATA[parboiling]]></category>
		<category><![CDATA[pharmaceutical]]></category>
		<category><![CDATA[plate heat exchangers]]></category>
		<category><![CDATA[preheating]]></category>
		<category><![CDATA[purification]]></category>
		<category><![CDATA[retrofit]]></category>
		<category><![CDATA[rice production]]></category>
		<category><![CDATA[solid sustainability]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[sustainability]]></category>
		<category><![CDATA[Tempco Green]]></category>
		<category><![CDATA[turbulent flow]]></category>
		<category><![CDATA[wastewater]]></category>
		<category><![CDATA[water treatment]]></category>
		<category><![CDATA[well water]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11443</guid>

					<description><![CDATA[<p>Tempco custom immersion plate heat exchangers arrays designed for energy-saving applications—specifically heat recovery from wastewater used for well-water preheating—installed in an equalization tank for parboiled rice production.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/">Wastewater heat recovery with custom immersion plate heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Tempco</strong> has implemented an interesting new energy-saving application using <strong>custom <a href="https://en.tempco.it/solutions-en/heat-exchangers/dimple-jacket/" target="_blank" rel="noopener">immersion plate heat exchangers</a></strong> for a client in the <strong>parboiled rice production</strong> sector. Specifically, for this project, Tempco manufactured and supplied t<strong>wo arrays of custom immersion heat exchangers</strong>—each consisting of 20 plates measuring 2500 x 500 mm, made of <strong>AISI 316L stainless steel</strong> with a 100 mm plate spacing. This custom application is of significant interest to energy managers and technical specialists across various industries, as it is ideally suited for other <a href="https://www.tempco.it/blog/en/10896/precision-and-hygiene-in-stainless-steel-for-pharma-and-food-thermoregulation/" target="_blank" rel="noopener"><strong>food and beverage</strong></a> production processes, as well as the <a href="https://www.tempco.it/blog/en/5453/dimple-plate-jacket-from-chemical-and-beyond/" target="_blank" rel="noopener"><strong>chemical</strong></a> and <a href="https://www.tempco.it/blog/en/8156/monofluid-thermoregulation-in-pharma-group-for-api-production/" target="_blank" rel="noopener"><strong>pharmaceutical</strong></a> sectors.</p>
<p>In this specific case, the <a href="https://www.tempco.it/blog/en/8796/energy-recovery-with-immersion-exchangers-in-industrial-laundries/" target="_blank" rel="noopener"><strong>immersion plate heat exchanger</strong></a> arrays have been installed in the <strong>equalization tank</strong>, which receives the <strong>wastewater generated by the parboiling process</strong>—consisting primarily of water used to soak the paddy rice. The purpose of the custom immersion plate heat exchanger is to <strong>recover heat from the wastewater</strong>, yielding a dual benefit: first, the recovered heat preheats well water circulating within the plates to the highest possible temperature, resulting in significant <strong>energy savings by reducing steam consumption</strong>. Second, the heat transfer process cools the wastewater before it is sent to the purification plant, providing a substantial advantage for the biological treatment processes taking place there.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-11444" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1.jpg" alt="Image showing arrays of custom immersion plate heat exchangers in an equalization tank, designed for energy saving through heat recovery from wastewater generated during rice production." width="701" height="419" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1.jpg 1284w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1-300x179.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1-1024x612.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-scambiatori-a-immersione-vasca-equalizzazione-coltura-riso-1-768x459.jpg 768w" sizes="auto, (max-width: 701px) 100vw, 701px" /></p>
<p>The system was implemented as <strong>custom and in retrofit</strong>, utilizing existing structures within the client’s equalization tank. Specifically, the <strong>existing agitators</strong> were leveraged to maintain a fluid velocity of ≥0.1 m/s, generating turbulence that enhances heat transfer efficiency. Furthermore, the immersion heat exchanger arrays were installed by anchoring them to decommissioned aeration pipes (2.0 x 2.6 m).</p>
<p>Overall, the system will enable significant energy savings for the client, <strong>recovering approximately 174 kW of heat</strong> (150,000 kcal/h) and saving 1,500–1,700 tonnes of steam per year. Material selection for the heat exchanger plates was also critical; <strong>AISI 316L stainless steel</strong> was chosen to ensure <a href="https://www.tempco.it/blog/en/10552/revamping-and-corrosion-protection-of-cooling-radiators-in-marine-installation/" target="_blank" rel="noopener"><strong>corrosion resistance</strong></a> (handling wastewater with a pH of 3.7–3.9 with no critical chloride levels). <a href="https://www.tempco.it/blog/en/9511/fouling-factor-each-type-of-exchanger-has-his-own/" target="_blank" rel="noopener"><strong>Fouling</strong></a> caused by starches in the wastewater was accounted for using a conservative fouling factor (4E-4 m²K/W). Finally, given the intermittent nature of the wastewater flow—process wastewater is discharged every two hours, though a minimum volume is always maintained in the tank—performance was calculated at 70% of the theoretical maximum to determine the system&#8217;s ROI.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9796/tempco-green-a-new-thermal-energy-for-a-solid-sustainability/" title="Permanent link to Tempco Green, a new thermal energy for a solid sustainability">Tempco Green, a new thermal energy for a solid sustainability</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/9733/hydrogen-and-thermal-management-for-the-green-energy-industry/" title="Permanent link to Hydrogen and thermal management for the Green Energy Industry">Hydrogen and thermal management for the Green Energy Industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8999/sustainability-and-heat-exchangers-a-whole-month-dedicated-to-renewables/" title="Permanent link to Sustainability and heat exchangers, a whole month dedicated to Renewables">Sustainability and heat exchangers, a whole month dedicated to Renewables</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8550/preventive-maintenance-for-heat-exchangers-efficiency/" title="Permanent link to Preventive maintenance for heat exchangers efficiency">Preventive maintenance for heat exchangers efficiency</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11443/wastewater-heat-recovery-with-custom-immersion-plate-heat-exchangers/">Wastewater heat recovery with custom immersion plate heat exchangers</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Five key data for heat exchangers sizing</title>
		<link>https://www.tempco.it/blog/en/11414/five-key-data-for-heat-exchangers-sizing/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 10 Jul 2026 09:34:55 +0000</pubDate>
				<category><![CDATA[Cooling]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[Heating]]></category>
		<category><![CDATA[Manualistica]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[Scambiatori a piastre]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[efficiency]]></category>
		<category><![CDATA[engineering]]></category>
		<category><![CDATA[exchangers]]></category>
		<category><![CDATA[flow rate]]></category>
		<category><![CDATA[fouling]]></category>
		<category><![CDATA[gas]]></category>
		<category><![CDATA[heat exchangers]]></category>
		<category><![CDATA[heating]]></category>
		<category><![CDATA[pressure]]></category>
		<category><![CDATA[pressure drop]]></category>
		<category><![CDATA[sizing]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[Tempco]]></category>
		<category><![CDATA[temperature]]></category>
		<category><![CDATA[thermal calculation]]></category>
		<category><![CDATA[tutorial]]></category>
		<category><![CDATA[viscosity]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11414</guid>

					<description><![CDATA[<p>Five thermal calculation parameters required to size heat exchangers, including fluid inlet and outlet temperatures, flow rates, and fluid pressure - the latter being critical for gases.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11414/five-key-data-for-heat-exchangers-sizing/">Five key data for heat exchangers sizing</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Tempco</strong> has created a clear, concise tutorial to simplify the selection of <strong>data needed to size <a href="https://en.tempco.it/solutions-en/heat-exchangers/" target="_blank" rel="noopener">heat exchangers</a></strong>. When performing <a href="https://www.tempco.it/blog/en/8801/five-fingers-rule-and-heat-exchangers/" target="_blank" rel="noopener">thermal calculations for heat exchangers</a>, it is not necessary to provide every data point listed in the document for completeness &#8211; only a specific subset is required.</p>
<p>In fact, as indicated in the documentation, just <strong>five of the listed data are necessary</strong> and sufficient: the &#8216;must-have&#8217; data &#8211; essential for initiating the sizing process- are those required for the <strong>thermal calculation</strong>:</p>
<ul>
<li>Primary fluid inlet and outlet temperatures</li>
<li>Primary fluid flow rate</li>
<li>Secondary fluid inlet and outlet temperatures</li>
<li>Secondary fluid flow rate</li>
<li>Fluid pressure (crucial in the case of gases)</li>
</ul>
<p><strong>Capacity</strong> is another important factor for the thermal sizing of the exchanger; however, if the other five data are available, capacity can be calculated from them.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11415" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN.jpg" alt="Image illustrating the essential and useful data for sizing heat exchangers." width="700" height="384" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN.jpg 1862w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-300x164.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-1024x561.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-768x421.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-cinque-dati-necessari-dimensionamento-scambiatori-EN-1536x841.jpg 1536w" sizes="auto, (max-width: 700px) 100vw, 700px" /></p>
<p>The other data listed under the heading &#8220;DATA FOR HEAT EXCHANGERS DESIGN AND CONSTRUCTION&#8221; are <strong>useful for a more precise and comprehensive design</strong> but are not essential for an initial thermal calculation:</p>
<ul>
<li>Fluid types</li>
<li>Max. operating temperature</li>
<li>Max. operating pressure</li>
<li>Oversizing % (margin)</li>
<li>Allowable pressure drops (primary and secondary)</li>
<li>Fluid viscosity</li>
<li>Fluid specific weight</li>
<li>Heat transfer coefficient</li>
<li>Fouling factor</li>
</ul>
<p>In summary, to begin the sizing process, it is <strong>essential to provide at least five of the listed thermal parameters</strong> &#8211; including <strong>pressure if a gas is involved</strong>. The remaining data help refine the unit&#8217;s design specifications but are not required at the initial stage. It is important to note that for <strong>special fluids</strong>, you must <a href="https://en.tempco.it/contacts/" target="_blank" rel="noopener"><strong>contact Tempco directly</strong></a>, as specified in the document.</p>
<p>FIVE FINGERS RULE<br />
<iframe loading="lazy" title="Conoscete la regola delle 5 dita?" width="750" height="422" src="https://www.youtube.com/embed/Tw3VHtWNgp4?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11417" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1019" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-1-1-1056x1536.jpg 1056w" sizes="auto, (max-width: 700px) 100vw, 700px" /> <img loading="lazy" decoding="async" class="aligncenter  wp-image-11419" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1018" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-2-1-1056x1536.jpg 1056w" sizes="auto, (max-width: 700px) 100vw, 700px" /> <img loading="lazy" decoding="async" class="aligncenter  wp-image-11421" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1018" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-3-1-1056x1536.jpg 1056w" sizes="auto, (max-width: 700px) 100vw, 700px" /> <img loading="lazy" decoding="async" class="aligncenter  wp-image-11423" src="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1.jpg" alt="Image illustrating the Tempco guide for selecting the data needed to size heat exchangers." width="700" height="1018" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1.jpg 1169w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-206x300.jpg 206w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-704x1024.jpg 704w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-768x1118.jpg 768w, https://www.tempco.it/blog/wp-content/uploads/2026/07/Tempco-tutorial-dati-dimensionamento-scambiatori-4-1-1056x1536.jpg 1056w" sizes="auto, (max-width: 700px) 100vw, 700px" /></p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/8801/five-fingers-rule-and-heat-exchangers/" title="Permanent link to Five fingers rule and heat exchangers">Five fingers rule and heat exchangers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11313/tempcos-spare-parts-ordering-guide-for-plate-heat-exchangers/" title="Permanent link to Tempco&#8217;s spare parts ordering guide for plate heat exchangers">Tempco&#8217;s spare parts ordering guide for plate heat exchangers</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8550/preventive-maintenance-for-heat-exchangers-efficiency/" title="Permanent link to Preventive maintenance for heat exchangers efficiency">Preventive maintenance for heat exchangers efficiency</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8569/fluids-flow-in-heat-exchangers-counter-flow-vs-parallel-flow/" title="Permanent link to Fluid’s flow in heat exchangers, counter-flow vs. parallel-flow">Fluid’s flow in heat exchangers, counter-flow vs. parallel-flow</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8999/sustainability-and-heat-exchangers-a-whole-month-dedicated-to-renewables/" title="Permanent link to Sustainability and heat exchangers, a whole month dedicated to Renewables">Sustainability and heat exchangers, a whole month dedicated to Renewables</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11414/five-key-data-for-heat-exchangers-sizing/">Five key data for heat exchangers sizing</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IP55-certified temperature control units for food &#038; beverage</title>
		<link>https://www.tempco.it/blog/en/11377/ip55-certified-temperature-control-units-for-food-beverage/</link>
		
		<dc:creator><![CDATA[Marco Zambelli]]></dc:creator>
		<pubDate>Fri, 19 Jun 2026 10:14:19 +0000</pubDate>
				<category><![CDATA[beer]]></category>
		<category><![CDATA[chocolate tempering]]></category>
		<category><![CDATA[Energia Termica @en]]></category>
		<category><![CDATA[Heat exchangers]]></category>
		<category><![CDATA[plate heat exchanger]]></category>
		<category><![CDATA[temperature control unit]]></category>
		<category><![CDATA[thermal energy]]></category>
		<category><![CDATA[Thermoregulation Unit]]></category>
		<category><![CDATA[beverage]]></category>
		<category><![CDATA[certifications]]></category>
		<category><![CDATA[chocolate]]></category>
		<category><![CDATA[food]]></category>
		<category><![CDATA[food industry]]></category>
		<category><![CDATA[hygiene requirements]]></category>
		<category><![CDATA[hygienic design]]></category>
		<category><![CDATA[IP55]]></category>
		<category><![CDATA[IP55 components]]></category>
		<category><![CDATA[milk]]></category>
		<category><![CDATA[pasta]]></category>
		<category><![CDATA[solid temperature]]></category>
		<category><![CDATA[temperature control]]></category>
		<category><![CDATA[temperature control units]]></category>
		<category><![CDATA[thermoregulation]]></category>
		<category><![CDATA[washing]]></category>
		<category><![CDATA[wine]]></category>
		<guid isPermaLink="false">https://www.tempco.it/blog/?p=11377</guid>

					<description><![CDATA[<p>Tempco can supply IP55-certified temperature control units to meet the hygienic requirements of food and beverage production, where equipment need to employ wash-resistant internal components.</p>
<p>L'articolo <a href="https://www.tempco.it/blog/en/11377/ip55-certified-temperature-control-units-for-food-beverage/">IP55-certified temperature control units for food &#038; beverage</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <a href="https://www.tempco.it/blog/en/10792/custom-thermoregulation-units-for-oems-in-the-food-pharma-sectors/" target="_blank" rel="noopener"><strong>food &amp; beverage industry</strong></a> presents numerous <strong>thermoregulation and temperature control tasks</strong> for the various food production and processing of materials. The need for careful temperature regulation in the various processing steps must also meet important and stringent <strong>hygienic requirements</strong> to ensure product quality, food safety, and saveguard consumer&#8217;s health.</p>
<p><a href="https://en.tempco.it/solutions-en/thermo-regulating-units/" target="_blank" rel="noopener"><strong>Temperature control units</strong></a> for use in <a href="https://www.tempco.it/blog/en/8361/temperature-regulation-for-flaking-and-lamination-in-food-and-pharma/" target="_blank" rel="noopener">food and beverage</a> production lines must therefore meet stringent requirements in terms of materials and design, ensuring <strong>hygienic design of equipments</strong>. Thanks to an audit conducted by a notified body for the certification of the internal components of our TREG temperature control units, Tempco is therefore now able to provide <strong>IP55-certified temperature control units</strong>. The IP55 certification of a component specifically indicates the level of protection a device provides against the ingress of dust and liquids.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-11378" src="https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-centraline-termoregolazione-certificate-IP55-food-beverage-1.jpg" alt="Illustrative image of Tempco TCU IP55-certified temperature control units for temperature control in the food and beverage industry." width="625" height="357" srcset="https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-centraline-termoregolazione-certificate-IP55-food-beverage-1.jpg 1344w, https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-centraline-termoregolazione-certificate-IP55-food-beverage-1-300x171.jpg 300w, https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-centraline-termoregolazione-certificate-IP55-food-beverage-1-1024x585.jpg 1024w, https://www.tempco.it/blog/wp-content/uploads/2026/06/Tempco-centraline-termoregolazione-certificate-IP55-food-beverage-1-768x439.jpg 768w" sizes="auto, (max-width: 625px) 100vw, 625px" /></p>
<p>This is further important addition to Tempco&#8217;s range of temperature control solutions for the food and beverage industry, where it already boasts a wide range of important and interesting applications, from <a href="https://www.tempco.it/blog/en/10718/thermoregulation-in-chocolate-refining/" target="_blank" rel="noopener"><strong>chocolate processing</strong></a> to <a href="https://www.tempco.it/blog/5680/pasta-cogenerazione-ed-efficienza/" target="_blank" rel="noopener"><strong>pasta</strong></a>, <a href="https://www.tempco.it/blog/en/10278/candies-production-and-temperature-control-treat-or-trick/" target="_blank" rel="noopener">candies and sweets</a>, <strong>milk</strong>, <a href="https://www.tempco.it/blog/en/8586/beer-wine-and-exchangers-thermal-treatments-in-food-processing/" target="_blank" rel="noopener"><strong>wine</strong></a>, and <a href="https://www.tempco.it/blog/en/8643/plate-heat-exchangers-and-brewing-beer-and-thermal-energy/" target="_blank" rel="noopener"><strong>beer</strong></a>, to name just a few. The ability to offer internal components for our TCU specifically designed with IP55 protection, to meet the needs of the food and beverage market which requires the ability to wash down equipment with water jets, therefore opens up a <strong>wide</strong> <strong>variety of new application opportunities for Tempco</strong>, to even better meet the temperature control needs of the food industry.</p>
<div class="betterrelated"><p><strong>Potrebbero interessarti anche:</strong></p>
<ol><li> <a href="https://www.tempco.it/blog/en/11220/temperature-control-units-for-reactors-at-30-c-in-the-pharma-industry/" title="Permanent link to Temperature control units for reactors at -30° C in the pharma industry">Temperature control units for reactors at -30° C in the pharma industry</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10896/precision-and-hygiene-in-stainless-steel-for-pharma-and-food-thermoregulation/" title="Permanent link to Precision and hygiene in stainless steel for pharma and food thermoregulation">Precision and hygiene in stainless steel for pharma and food thermoregulation</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/8564/newly-refurbished-references-section-in-tempcos-website/" title="Permanent link to Newly refurbished References section in Tempco’s website">Newly refurbished References section in Tempco’s website</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/10278/candies-production-and-temperature-control-treat-or-trick/" title="Permanent link to Candies production and temperature control&#8230; treat or trick?">Candies production and temperature control&#8230; treat or trick?</a>  </li>
<li> <a href="https://www.tempco.it/blog/en/11485/atex-zone-tcu-temperature-control-units-maximum-efficiency-with-control-panel-in-safe-area/" title="Permanent link to ATEX zone TCU temperature control units, maximum efficiency with control panel in safe area">ATEX zone TCU temperature control units, maximum efficiency with control panel in safe area</a>  </li>
</ol></div><p>L'articolo <a href="https://www.tempco.it/blog/en/11377/ip55-certified-temperature-control-units-for-food-beverage/">IP55-certified temperature control units for food &#038; beverage</a> proviene da <a href="https://www.tempco.it/blog/en/">Tempco Blog</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>